Post by mawaloc on KeyPad Function in Visualization to fill a table
CODESYS Forge
talk
(Post)
Hello Everybody, Hope you're all doing good for this new year. Since a time, I'm looking on how to use the KeyPad in vizualization to fill a textlist or something similar. my application is : In one window, I would need to be able to writte a string linked to an Numeric Values. => I can't use a std text list inside my software, as per this would be custom by customer. then from another windows I would need a "text box" to be able to select any of this String. I hope it's clear enought. thankyou for the help
Last updated: 2026-01-07
Post by mubeta on Some 'pathetic' errors in SoftMotion program
CODESYS Forge
talk
(Post)
Thank you for your interest. Your answers are in line with what I knew, so at least it comforts me that I did not misinterpret the situation. However, I don't have an exact match as, for this project over the past few days I have: 1) I have gone back to leaving the various FBs of the motion always called, all of them, and in the state machine I use a boolean to activate the various useful Execute. (But in the future I want to go back and try the programming technique with which I wanted to develop this project); 2) For the occasional error: SMC_FB_WASNT_CALLED_DURING_MOTION perhaps it was due to the fact that I had set the Ethercat bus synchronism only at the CAN master level, but not at the level of individual drives. I have now also activated it for the individual drives and it does indeed seem to have been resolved, but having also adopted the programming technique mentioned in point 1), I cannot say whether this was the solution to the problem, or instead the previous point. Is there an error ‘regulator or start not set’ in the device log before the error ‘motion generating FB wasn't called for at least one cycle’? I can't answer that right now. By now the machine is running and I am no longer there, at this one. Also, I seem to remember that the 'fbeFBerror' drive structure (5-element array), does not cycle, BUT ONCE THE 5 EVENTS AFTER SWITCHING ON, IT DOES NOT UPDATE ANYMORE (but that's another issue), so diagnostics were not easy.
Last updated: 2024-07-24
Post by timvh on Sysfile inuts
CODESYS Forge
talk
(Post)
To prevent ambiguous use of this enumeration value. Let's say another ENUM is available in your project or in another library which has an enumeration value AM_WRITE, then it is not clear which AM_WRITE you want to assign. By this qualified access to the SysFile.AM_WRITE, it is completely clear for the compiler.
Last updated: 2024-01-14
Post by canplum on Codesys 3.5.21 fails to copy file to USB
CODESYS Forge
talk
(Post)
Although I have set in /etc/codesyscontrol/CODESYSControl_User.cfg the [SysFile] PlaceholderFilePath.1=/media/pi, $usb$ PlaceholderFilePath.1.View=1 PlaceholderFilePath.1.Volatile=1 I am not able to copy a file to this directory defined by the placeholder. Neither SysProcess.SysProcessExecuteCommand2 nor SysFileCopy nor FileCopy is working. If I try to copy the same file to /home/pi all is working fine. I also can create and open a different file by using SysFileOpen. I don't understand why the system allows to open (create) and write files into that directory but doesn't allow to copy into it. Obviously there is a rights problem with the USB drive. I have already set the permissions to drwxr-xr-x 2 and the user to pi but without any success. With 3.5.16 I never had such an issue. Is there anybody with some hints how to solve that problem? Cheers, canplum
Last updated: 2025-05-23
Post by wbj0t on Global variable access by Programms and Modbus Devices (attach device to bus)
CODESYS Forge
talk
(Post)
Hi everyone. I use Raspberry Pi 4, one core codesys SL. I have a question about global variable access via programm when I glued the same variable to MODBUS SERIAL/TCP DEVICE holding register. So, the question: what behavior of this modifying? When I set "Always update variables (in bus cycle)" and set some task as bus for the Device, then in another task I cant change this varible (can, but immediatly the old value setted again). But the same things works with MODBUS SLAVE: again "Always update..." and master attached to some task, then I change variable in another task and all works. I cant set up my variables from retains file at PrepareStart event because of this behavior with MODBUS SERIAL/TCP DEVICE. Thanks, wbj0t.
Last updated: 2024-07-18
Post by rschwager on GVL to SHMem
CODESYS Forge
talk
(Post)
Hallo! Have some any idea to transfer whole GVL to Shared Memory? I also shared REATIN memory to shraed meory for making a Retain Backup System without USP in Linux on a FRAM. For an other Application we want to shared the whole GVL off obne part (e.g. GVL_Test). How cvan I get easy the Size and the Address for meory copy?
Last updated: 2024-07-09
Post by dnordenberg on BOOL variable in OPC UA and modbus simultaneously
CODESYS Forge
talk
(Post)
How can I have an BOOL variable that is read/write in both modbus TCP server and from OPC UA at the same time? Variables with %MX.n %QX.n addressing which is used for BOOL/coils in modbus server is not allowed in OPC UA symbol list on Schneider M251 controllers. I have already asked on Schneiders forum but there are not a lot of codesys experts over there :( So OPC symbols can't have a address and the modbus TCP server needs a address. So how should I do it then? It seems like an impossible combination. Since I want read/write access from both ways I can't just simply make a second variable and assign it the value of another since it would be a one way assignment. I also tried using VAR_CONFIG which then makes the address syntax %Q or %M in my main variable list and that fools OPC UA Symbol Configuration to allow it and then I add the complete %MX.n address of it in the VAR_CONFIG list. This semi works, I can toggle the BOOL from modbus but the OPC UA symbol seems to be read only. It displays symbol status but nothing happens when I toogle it. I think I need another way to have the variables and symbols pointing to the same bits in memory... My plan B is to write a BOOL array compare FB that saves a history bit from previous cycle and if that does not match current status at next cycle for either the OPC symbol or the modbus variable then it copies the new status over to the other. Maybe ugly but it's like my last alternative. Kind regards David
Last updated: 2025-07-14
Post by altus22 on Type SM3_Drive is not equal to type SM3_Drive
CODESYS Forge
talk
(Post)
Another way to resolve this is to set Codesys to use a specific version of the offending library under Placeholders in the Library Manager.
Last updated: 2025-04-17
Post by joschi2804 on Licensing info not available.
CODESYS Forge
talk
(Post)
Hi, maybe this fixes your problem. At least this was our issue back then. We tried to run the codesys runtime environment on an embedded Linux system. The problem on our side was that we changed the WORKDIR directory in the /etc/init.d/codesyscontrol script to /home/user/codesys, but we forgot to copy all files (including the hidden files) from the initial WORKDIR (I am not sure but I guess the initial WORKDIR was /var/opt/codesys) to the new one. After copying those files and restarting codemeter and codesyscontrol, we were able to upload licenses. Hope this help BR Josef
Last updated: 2024-07-10
Post by zatalian on Beckhoff EL7037 softmotion
CODESYS Forge
talk
(Post)
The SM3_Drive_ETC_Beckhoff_EL70xx library has descriptors for the EL7031, EL7041 and EL7047 but not the EL7037? Is there another library that has the one I need?
Last updated: 2024-11-26
Post by nz-dave on FAILURE TO OPEN PROJECT ON ANOTHER COMPUTER
CODESYS Forge
talk
(Post)
just now i have tried loading the achive file from today at work. using 3.5.20.4 same as at work. when i open the project it says " prject inspection, this project has been saved with a different version(codesys v3.5 sp20 patch 4).? one option in the above "project inspection" window just wants to download that same version again. the other option leads no where as it say the required add ons cant be resolved. just end up going around in circles.
Last updated: 2025-01-22
Post by ppanchal on Add a dynamic text on One Visualization from another
CODESYS Forge
talk
(Post)
I've created a TitleBar Visualization in which I have "Logo" on the Left corner, "Screen Name" in the center and Time/ date on the right corner. I've also created a 'Menu" visualization that slides out from left to right. I have TitleBar and Menu Visualizations in the MainScreen (3rd Visualization). I want to have "Screen Name" automatically updated on TitleBar Visualization based on Menu item selected from the "Menu" visualization. Can anyone advise how can I achive this? TIA
Last updated: 2025-11-18
Post by miltos on licensing question
CODESYS Forge
talk
(Post)
Greetings to all, I'm working on a webvisu project on control win V3 x64 runtime, and have purchased 3 licenses for my application. -Codesys Control Standard M -Codesys Visualization L -Codesys Communication M I have them installed on a Codesys usb dongle When I try to download the program, a login error window appears with the message "No valid license found for the webvisualization". The control win v3 communicates with 3 plc, and have enabled communication over codesys V3 communication by adding one datasource for every plc in the datamanager. If I remove the data manager from the project, the rest of the visualisation can be downloaded normally. Do I need to purchase another License and which one? Please find attached the software metrics and the error screen.
Last updated: 2025-10-31
Post by darwin03 on Mismatch between coordinate monitor and actual motion using SMC_GroupJog2, MC_MoveLinearAbsolute (6DOF)
CODESYS Forge
talk
(Post)
Dear Georg, Thank you for your explanation about the axis scaling. I checked the scaling of Joint6 and corrected it so that one technical unit equals one angular degree. However, I am now facing another issue. When I move all axes to zero position and then try to use SMC_GroupJog2 and MC_MoveLinearAbsolute, I receive the error SMC_CP_CONFIGS_DIFFER I already tried moving each joint manually to different positions before executing the motion command, but the error still appears. Could you please explain: What exactly causes SMC_CP_CONFIGS_DIFFER Thank you very much for your support. Best regards, darwin03
Last updated: 2026-05-04
Post by tortilla on J1939 connection between two devices
CODESYS Forge
talk
(Post)
Hey, I'm pretty new to CoDeSys so I don't know a lot of things yet. I have to create a connection between two devices (CANbus - J1939 connection). The idea for now is to send a message from one to another (one operates on 3.5 SP11 the other one on 2.3) I watched a few videos, worked with the documentation and worked with chatGPT 4o and was able to build the attached file. This part is about the device on 3.5.11: I'm using the J1939LocalECUDiag, TransmitParameterGroup, TransmissionTrigger Function blocks to send the message but my TransmitPG.xBusy / .xDone never turns to True and therefore my message is not sent while TransmitPG.xExcecute is True. I added the two devices in the CANbus in the J1939Manager and addapted the options like I've seen in the documentation. Can anyone explain what's wrong with my code in this casse or give me advices how to properly create a connection between my two devices? Thanks in advance!
Last updated: 2024-05-23
Post by gordonkeller360 on Escape character behavior for hex values in string -- what gives?
CODESYS Forge
talk
(Post)
I have a program which sequentially places byte representations of characters from a string into an array. FUNCTION_BLOCK MoveBytesFromString VAR_IN_OUT abRxBuf: ARRAY [0..79] OF BYTE; END_VAR VAR testString : STRING := '$0A$R$L$TTesting,123...$94$86$0A'; iCount: DINT; END_VAR ---------------------------------------------------------------------------------------- // clear the buffer MEM.MemFill(ADR(abRxBuf), 80, 0); FOR iCount := 0 TO LEN(testString) - 1 DO // account for undesired null terminator of string abRxBuf[iCount] := testString[iCount]; END_FOR Escaped characters, like $T, $N, etc. work just fine, and so do their hex representation counterparts ($09, $0A, etc). However, when I put something like $94, I get a set of nonsense values... see image attached after one spin of the program. Could someone explain to me what is happening here? I'll continue to investigate...
Last updated: 2026-03-09
Post by timvh on Limiting Memory Access of an Array to Within its Bounds
CODESYS Forge
talk
(Post)
Add the object "POU for Implicit Checks" to your application, then select "Bounds check". This will create a function which is automatically called each time an array is write accessed. In the function you can handle "out of bounds" situations. By default it will be limited to its lower or upper bound.
Last updated: 2024-03-06
Post by leon78 on Codesys 3.5 SP17 Patch 2 CheckBounds (POUs for Implicit Checks)
CODESYS Forge
talk
(Post)
Hello! I use CheckBounds (POUs for Implicit Checks). But I have a problem. I use an array as an VAR_IN_OUT of Function Block. If I try to monitor the array of variable length ([* ]), its does't work. The CheckBounds POU isn't called. If I use the array of fixed lenght ([lower..upper]), the CheckBounds POU is called. Why?
Last updated: 2023-11-14
Post by leon78 on Codesys 3.5 SP17 Patch 2 CheckBounds (POUs for Implicit Checks)
CODESYS Forge
talk
(Post)
Hello! I use CheckBounds (POUs for Implicit Checks). But I have a problem. I use an array as an VAR_IN_OUT of Function Block. If I try to monitor the array of variable length ([* ]), its does't work. The CheckBounds POU isn't called. If I use the array of fixed lenght ([lower..upper]), the CheckBounds POU is called. Why?
Last updated: 2023-11-14
Post by gurkan on OPCUA array max length?
CODESYS Forge
talk
(Post)
We are using codesys 3.5.16.30 and we have a array with strings of length 5000. We are having issues subscribing to this variable from an OPCUA client. Is there any limit in the OPCUA Server in codesys for how long an array can be on the opcua server?
Last updated: 2024-02-16
Post by alexgooi on Init Array input on a method
CODESYS Forge
talk
(Post)
Dear Forum, I would like to initialize an array input on a method. When I do this, I get the following error: "The type of ARRAY [1..2] OF BOOL cannot have a default value in this context." I attached a picture for more clarity. Is this simply not possible or is there a different way of tackling this problem? Thank you in advance
Last updated: 2024-02-26
Post by kreisfilho on Same program to more than one PLC
CODESYS Forge
talk
(Post)
Hi, How can I assign a monitor (non touch) connected to a Raspberry pi (via HDMI) as visualization output?
Last updated: 2023-08-23
Post by nz-dave on FAILURE TO OPEN PROJECT ON ANOTHER COMPUTER
CODESYS Forge
talk
(Post)
cheers i will give that a go.
Last updated: 2025-01-22
Post by rckalex on Changing Trace Variable at Runtime
CODESYS Forge
talk
(Post)
Is it possible to change the variable being traced during runtime? I would like to use the CURRENTCLIENTID in combination with an array of real numbers to alter the traced variable in a display window, without needing to create separate visualizations for each variable.
Last updated: 2025-01-22
Post by gurkan on OPCUA array max length?
CODESYS Forge
talk
(Post)
2000 works. When testing with UA Expert there is a timeout from the OPCUA Server when trying to subscribe to the variable CPU do not seems to be to affected. The memory(RAM) however is building up
Last updated: 2024-02-19
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.