Post by food on Beaglebone Black OPC-UA Server CODESYS Forge talk (Post)
Man, this was a long time ago. I think the problem probably stemmed from not loading the certificates from the client and the server on the server and client respectively in the correct manner. I believe I ended up getting around it just by removing all security on the server. In the end we did not move forward with that architecture so I never had to actually fix it.
Last updated: 2024-04-10

Post by eschwellinger on CODESYS Automation Server Connector for 3.5 SP11 CODESYS Forge talk (Post)
https://store.codesys.com/en/codesys-automation-server-connector.html Programming System CODESYS Development System V3.5.15.0 or higher
Last updated: 2023-08-30

Post by alexgooi on Codesys OPC DA server requires more then 2 GB of ram CODESYS Forge talk (Post)
My colleague has found a tool online, Now it is possible to go to 4 GB instead of 2, which is plenty for now: https://www.techpowerup.com/forums/threads/large-address-aware.112556/ Use at own risk
Last updated: 2024-01-25

Post by elayaraj on Codesys Soft PLC OPC UA server CODESYS Forge talk (Post)
Hi, You may refer to this below video link to get some idea.. hopefully it works https://www.youtube.com/watch?v=RBMff-IlPA4
Last updated: 2024-08-30

Post by eschwellinger on VPN CODESYS Forge talk (Post)
Give CODESYS Automation Server a try!
Last updated: 2023-09-06

Post by vincentd on Datasource OPC UA Client error ID:7012 CODESYS Forge talk (Post)
I have not used this client / server OPC UA combination since. We were only making some kind of proof of concept. I did understand that there could be some kind of bug. I do not know if the supposed bug has been resoved since. Perhaps you could try what piautomation is suggesting
Last updated: 2024-04-05

Post by stiller on OPC UA RPI 4.8.0.0 Status Code / "out of range" CODESYS Forge talk (Post)
Hello, I have an OPC-UA server with an information model. For many values, there is a defined range (e.g., 0 to 100). If a client enters a value outside this range (e.g., 120), the StatusCode should change to Bad. How can I accomplish this? Any help is appreciated! Thank you in advance. Best regards, Christian Stiller
Last updated: 2024-07-10

Post by yr00 on OPC UA datasource low read frequency CODESYS Forge talk (Post)
Hello everyone, I am trying to test the OPC UA client feature in Codesys. My setup is the following; I have a Codesys simulation/ visualization running on Control Win V3. My OPC UA server is hosted on a Siemens 1518 PLC using PLCSim Advanced. The setup is completely virtual so there are no really PLCs. Everything is on my laptop. Writing data from the Codesys simualtion to the server is very quick. I have a PLC program running on another 1500 PLC which reads data from simulation via the server, and changes in the simulation (e.g. button pressed) appear within hundreds of miliseconds if not tens of miliseconds in my PLC program. However, when it comes to reading data from the OPC UA Server by Codesys, it taks around 1-2s. I connected a UAExpert client and it gets update very quickly so I am fairly sure the problem is with Codesys. I have tried changing the update rate in datasource -> General and Diagnosis, but it doesn't seem to have an effect. Do you guys have any suggestion on what I can do?
Last updated: 2023-08-29

Post by mainak on Opaque NodeId in the OPC UA server CODESYS Forge talk (Post)
Hello all, I am using the OPC UA server with my custom information model. I have used the communication manager to add my information model under my application and created instances from OPC UA types. I see that the created instances in the OPC UA server has some opaque nodeid (attached screenshot) and I want to change that. Therefore I have the following questions: 1. Is there a way to configure the NodeIds of instances in the OPC UA server? I tried to edit it using the UaExpert client but got error "BadNotWriteable". is it possible to configure it somewhere so that the nodeids can be changed using an external client? 2. Is there a way to define the rule for creating instance nodeids within the codesys IDE? 3. Is it possible to create the instances before e.g. using a modelling tool like UaModeler and import them as part of the information model and use them later? Using the communication manager, I can only create instances from types. I couldn't find a way to map my existing instances to plc tags from my application. It would be nice if someone could help me with these issues. Thanks in advance. :)
Last updated: 2024-10-19

Eine Nummer (Data Type=Double) Schicken mit TCP Client Server Codesys CODESYS Forge talk (Thread)
Eine Nummer (Data Type=Double) Schicken mit TCP Client Server Codesys
Last updated: 2021-09-08

Send RESTful commands to an external non CODESYS device server and HTML Script editing CODESYS Forge talk (Thread)
Send RESTful commands to an external non CODESYS device server and HTML Script editing
Last updated: 2021-06-10

Eine Nummer (Data Type=Double) Schicken mit TCP Client Server Codesys CODESYS Forge talk (Thread)
Eine Nummer (Data Type=Double) Schicken mit TCP Client Server Codesys
Last updated: 2021-09-08

CoDeSys Control for PFC200 ModbusTCP Server Returns Exception:' Gateway path unavailable' CODESYS Forge talk (Thread)
CoDeSys Control for PFC200 ModbusTCP Server Returns Exception:' Gateway path unavailable'
Last updated: 2020-08-18

Post by janderson on OPC UA Server limitations, large array crashes runtime CODESYS Forge talk (Post)
when using an array of structs, the runtime crashes. but when using an array of LREALS, it'll do 100k at least
Last updated: 2023-08-23

Post by eschwellinger on OPCUA Ctrl-Node fehlt CODESYS Forge talk (Post)
..dann mal im WBM alles deaktivieren, da der OPC UA Server ja direkt im PFC200 SL RUntime integriert ist und nicht über die WBM Oberfläche zu konfigurieren ist.
Last updated: 2023-12-05

Post by bryandimino on OPC Da Server Code Meter Issues after Enabling License CODESYS Forge talk (Post)
Additionally the license is loaded on the soft storage for my device but it shows up as invalid. I just activated it today.
Last updated: 2024-05-02

Post by stiller on OPC-UA ApplicationUri / ProductUri CODESYS Forge talk (Post)
Hello! Is there a way to change ApplicationUri and ProductUri of the OPC_UA server? I can not find any information about it. Does someone have a clue? Thank you in advance!
Last updated: 2024-05-10

Post by shabroz-gill on Data Sources Manager causing exception due to float or double type in OPC server CODESYS Forge talk (Post)
Was this ever resolved? I see the same issue with the version 3.5.19.5
Last updated: 2024-07-01

Post by peterned on Programatically restart Codesys OPC UA server? CODESYS Forge talk (Post)
Hi, I'm using a Festo Codesys PLC (CPX-CEC-C1-V3), which is connected to a HMI panel. Both exchange data via OPC UA. Occasionally, the HMI stops displaying data, and looks as if there is no connection. If the HMI stops, the only way to make it work again is to restart the PLC. Restarting HMI has no effect. When the PLC is restarted, HMI starts working normally again. Is it possible to restart the OPC UA server from PLC code? I hope this will make fixing the HMI possible without a PLC restart. Thanks
Last updated: 2024-07-19

Post by gediminas on Datasource OPC UA client system failure CODESYS Forge talk (Post)
I am using CODESYS v3.5 SP20 Patch 3 / Control for BeagleboneBlack SL v4.13 and after some time the OPC UA Server crashes. However, Runtime still works without any issues. The events leading up to the OPC server crash are the most suspicious: 1) Mutex deadlock detected - owner thread died, and 2) Runtime received SIGABRT. And it seems very similar with this topic except used versions - issues should be fixed with previous SP's. I can't seem to find any information about these events. Need some pointers in the right direction on how I can fix this problem.
Last updated: 2024-10-25

Post by arundara on OPC UA Server Stops after 5 consecutive disconnections of ethernet port CODESYS Forge talk (Post)
Hello Every one, During testing of OPC UA communication between UA Expert software and the CODESYS SoftPLC on a Linux environment, an observation was made. When the Ethernet cable was disconnected and reconnected with 2-minute intervals, on the 5th attempt, the OPC UA connection failed to establish in UA Expert software. At this juncture, restarting the CODESYS SoftPLC enabled the reestablishment of OPC UA communication. The same result was obtained when testing on a Raspberry Pi SoftPLC. What is the reason behind this phenomenon? and whether there are settings to stop this behavior? Please help. Thanks & Regards.
Last updated: 2024-02-13

enabling OPC UA connectivity while using motion control SM3_basic library gives build error CODESYS Forge talk (Thread)
enabling OPC UA connectivity while using motion control SM3_basic library gives build error
Last updated: 2018-08-22

OPC-UA errors in log, how do I interpret the error codes? CODESYS Forge talk (Thread)
OPC-UA errors in log, how do I interpret the error codes?
Last updated: 2021-02-05

Application stops automatically after few seconds for OPC UA add-on CODESYS Forge talk (Thread)
Application stops automatically after few seconds for OPC UA add-on
Last updated: 2020-10-20

Keine Daten vom OPC wenn 2 PLC und eine davon keine.. GELÖST CODESYS Forge talk (Thread)
Keine Daten vom OPC wenn 2 PLC und eine davon keine.. GELÖST
Last updated: 2012-07-26