Post by calviniscoding on JSON CODESYS Forge talk (Post)
Can you post the new code that you have by chance? Also, are you able to send the values of tags dynamically with the RTAC in this JSON format? I'm running into a lot of road blocks with it.
Last updated: 2024-06-21

Post by calviniscoding on JSON CODESYS Forge talk (Post)
Can you post the new code that you have by chance? Also, are you able to send the values of tags dynamically with the RTAC in this JSON format? I'm running into a lot of road blocks with it.
Last updated: 2024-06-21

Post by calviniscoding on JSON CODESYS Forge talk (Post)
Can you post the new code that you have by chance? Also, are you able to send the values of tags dynamically with the RTAC in this JSON format? I'm running into a lot of road blocks with it.
Last updated: 2024-06-21

Post by kthomas on Cant login to Rpi4 but can see it in codesys communications settings. CODESYS Forge talk (Post)
This is what I see in codesys window. And here is with the netstat command on the pi
Last updated: 2024-06-23

Post by eschwellinger on Two OneWireMaster on one Raspberry PI 5 CODESYS Forge talk (Post)
you need to have an own task for the one wire and io update these slaves in an own low prio task!
Last updated: 2025-10-18

Post by s1mon on Two OneWireMaster on one Raspberry PI 5 CODESYS Forge talk (Post)
yes sure. Thx for your support! This is the Codesys project stripped down only to my EtherCat and OneWire Configuration. The Project now contains only one OneWire Master on GPIO4.
Last updated: 2025-10-20

Post by eschwellinger on Two OneWireMaster on one Raspberry PI 5 CODESYS Forge talk (Post)
the project has only one OneWire Master - so if you add the setting "PlaceholderFilePath.2=/sys/devices/w1_bus_master2, $OneWire2$ to the config file it will fail and the Ethercat task will be blocked by the OneWire Master readings?
Last updated: 2025-10-21

Post by eschwellinger on Two OneWireMaster on one Raspberry PI 5 CODESYS Forge talk (Post)
Could you check the taskcycle time in the taskmonitor (online monitor) - do you really see this 1s on Ethercat Task? Need to check this on my hardware but will take some time...
Last updated: 2025-10-21

Post by alimans on Unrecoverable SoftMotion state after switch to PreOp CODESYS Forge talk (Post)
Hi Kim, Hi eschwellinger, how you could solve the problem? I am using Codesys V3.5.19.60 and I still have the same problem. It will work only after a warm/cold restart. Thank you in advance for your kind help.
Last updated: 2025-10-22

Post by eschwellinger on License Reset Request – CODESYS Control Win V3 Standard L CODESYS Forge talk (Post)
Please write these kind of request to 'my question' in the CODESYS Store. please do not use ticket and softcontainer numbers here.
Last updated: 2025-10-23

Post by kporter on Exception with ReadNbrSlaves function CODESYS Forge talk (Post)
I've been playing with the code using the Windows soft master and the ReadNbrSlaves function block seems to work here: https://content.helpme-codesys.com/en/libs/EtherCATStack/4.8.0.0/EtherCATStack/pou-ETCMasterStack/DynamicConfig/fld-DynamicConfig.html
Last updated: 2025-10-31

Post by farren on How to stay in a method until something is finished. CODESYS Forge talk (Post)
I know I'm thinking about this wrong -- too many decades of procedural and event-driven programming and only a few months of PLC ST programming...... I've created a visualization with a button that when pushed calls a method. I want the method to take a pressure reading, wait one minute and then take another pressure reading. I'm looking for leaks. I'm using TON for the delay. It seems like what is happening is that the method gets called once and it takes the first reading and starts the TON. But then execution continues, leaves that method call, and the second reading never happens. I can force the method to keep running until the whole thing is done with a While loop, but I understand that is considered BAD in PLC programming. If it push the button again to call the method again, it picks up where it left off and if the timer is complete then it runs the remaining code. How do I keep that method running until it is complete with just one call without using a while loop that ties up the PLC for a minute? Thanks! -Farren
Last updated: 2025-10-31

Post by gseidel on SMC_FB_WASNT_CALLED_DURING_MOTION when enable MC_MoveRelative CODESYS Forge talk (Post)
Hi ducng, please make sure to call all Motion-FBs in the EtherCAT task. In your case, the PLC_PRG should be below the EtherCAT task, not the MainTask. Best regards, Georg
Last updated: 2025-11-03

Post by nano on What is the prerequisites for a Raspberry Pi to work with SysSockSetIpAddressAndNetMask() CODESYS Forge talk (Post)
have u turned on the Ip-Setter in codesyscontrol.cfg? [SysSocket] Adapter.0.Name="eth0" Adapter.0.EnableSetIpAndMask=1
Last updated: 2025-11-11

Post by eschwellinger on Stepper motor control with (SM_Drive_RaspStepper_direct) CODESYS Forge talk (Post)
.. try to use this projectarchive for the Stepper. In case you search for SoftMotion Examples: "c:\Program Files\CODESYS 3.5.21.X\CODESYS\CODESYS SoftMotion\Examples\Tutorial\"
Last updated: 2025-11-11

Post by shaunvdm on OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3 CODESYS Forge talk (Post)
Hi All, We downgraded Codesys LAD/FB in the IDE to version 4.5 and it works. Codesys Version 4.6 lad/fb not working. Was the way we fixed this. Kind Regards Shaun
Last updated: 2025-11-17

Post by tristan on Textfield display problem CODESYS Forge talk (Post)
Hello everyone, I have a little problem with textfield display. When I put a solid backgroud, no problem. But when I put it to invisible, some strange things appears with the text. Do you have this kind of issues ? Thanks a lot, Tristan
Last updated: 2025-11-20

Post by timvh on Error: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr CODESYS Forge talk (Post)
Maybe check: - The library manager, are you maybe missing some libraries - Tools - CODESYS installer: update the CODESYS Visualization and Visualization support - Project - Project environment: maybe you need to update the visualization profile
Last updated: 2025-11-27

Post by gseidel on STEPPER CODESYS SOFTMOTION_DRIVE CODESYS Forge talk (Post)
Hi kalmeyer, I would recommend to have a look at these examples. They come with a project and a description: https://content.helpme-codesys.com/en/CODESYS%20SoftMotion/_sm_basic_examples_single_axis.html. Best regards, Georg
Last updated: 2025-11-28

Post by eschwellinger on Accessing parameters from a structure or function block with the web interface CODESYS Forge talk (Post)
yes, but you could use a demo project in the analyzer to check other types: https://analyzer-eu.automation-server.com/help/en/tags this should work.
Last updated: 2025-12-02

Post by mbart on VAR_INFO from inside of a FB to get info on the instance. CODESYS Forge talk (Post)
I experienced the same problem: using __VARINFO is working only in PRG context, while it crashes if used inside Function Blocks. I would really appreciate if they would fix this issue
Last updated: 2025-12-04

Post by kenth1973 on MC_Phasing state explenation CODESYS Forge talk (Post)
Hi George - ok thanks - but who created this FB in the first place? Could you lead me to the creator company? Is CODESYS not the old S3 that created this FB? :-)
Last updated: 2025-12-17

Post by unusual-data on C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr CODESYS Forge talk (Post)
you can try to disable "Visualization Manager - Settings - Support client animations and overlay of native elements " selection" It worked for me, thank you.
Last updated: 2025-12-18

Post by scrollman on Attribute FB for comment CODESYS Forge talk (Post)
Hello, I can use {attribute 'reflection'} FUNCTION_BLOCK POU VAR {attribute 'instance-path'} {attribute 'noinit'} str: STRING; END_VAR to get name of FB. How I can get the comment of FB, in the same way in the FB? Thank you for your time!
Last updated: 2025-12-31

Post by timvh on Modbus TCP Server connection is ESTABLISHED but all holding registers are value 0? CODESYS Forge talk (Post)
Are you sure you need to read holding registers? Have you tried reading input registers?
Last updated: 2026-01-07