Post by codesysdave on CoDeSys 3.5 SP20 "No Offline Help installed"
CODESYS Forge
talk
(Post)
What does this message mean, in the Errors/Messages box? "[ERROR] MyProjectName: No Offline Help installed" In CDS23, I used to be able to select a system function with the mouse, and press F1. Help and description would popup. How do I get so-called On-line Help installed?
Last updated: 2024-09-06
Post by anoori on Setting up Raspberry pi as an Opc ua Server with UaExpert as Client
CODESYS Forge
talk
(Post)
I am trying to set up my Raspberry Pi as an OPC UA server and use UaExpert on my Pc as the OPC UA client.However, Im encountering some certificate-related errors in UaExpert: 1.Unable to get local issuer certificate. 2. Unable to get certificate CRL. 3. Unable to verify the first certificate.
Last updated: 2024-09-11
Post by anoori on setting up Raspberry pi as an opc ua Server with UaExpert as Client
CODESYS Forge
talk
(Post)
I am trying to set up my Raspberry Pi as an OPC UA server and use UaExpert on my Pc as the OPC UA client.However, Im encountering some certificate-related errors in UaExpert: 1.Unable to get local issuer certificate. 2. Unable to get certificate CRL. 3. Unable to verify the first certificate.
Last updated: 2024-09-11
Post by garmusd on Raspberry Pi 5 GPIO not working.
CODESYS Forge
talk
(Post)
Hi, Codesyscontrol 4.13.0.0 Raspberry Pi5 64bit with latest updates. Cant get working GPIO - no output and no input. SPI/I2C not tested. GPIOs B+/Pi2, Input/Output is set in the parameters, assigned variables int the Mapping. Absolutely no reaction. Do I need to configure anything else to make it work? Thanks!
Last updated: 2024-09-26
Post by timvh on FB string and naming
CODESYS Forge
talk
(Post)
Really not clear what you are trying to do, but isn't a Struct enough? So add an object of the type DUT to the Application. Then create a structure TYPE ST_Sensor : STRUCT sName : STRING; uiNumber : UINT; END_STRUCT END_TYPE Then in you application add an instance of this Structure stSensor1 : ST_Sensor := (sName := 'my sensor', uiNumber := 1); or use it like this stSensor1.sName := 'my sensor';
Last updated: 2024-09-28
Post by janber on REFERENCE TO in an array
CODESYS Forge
talk
(Post)
Hi all, in the online help it written, that array of reference to data type is not possible. Ok... but if I create array of struct of reference to - everything works fine - please see the screenshots: and it works this way OK. Is it intention or error in compiler 3.5.18.20 and we should avoid it? Thanks a lot, Jan.
Last updated: 2024-10-14
Post by phoward131 on Alarm Table Filtering
CODESYS Forge
talk
(Post)
I actually just found the solution maybe. If anyone else is running into this, go to your Project Settings > Visualization > Advanced (check 'Visible' to see advanced settings) > UNCHECK 'Activate property handling in all element properties.' I am not sure what else unchecking this might affect but it seems to allow the alarm table to be filtered as expected.
Last updated: 2024-10-28
Post by phoward131 on Alarm filtering latch variables
CODESYS Forge
talk
(Post)
I actually just found the solution maybe. If anyone else is running into this, go to your Project Settings > Visualization > Advanced (check 'Visible' to see advanced settings) > UNCHECK 'Activate property handling in all element properties.' I am not sure what else unchecking this might affect but it seems to allow the alarm table to be filtered as expected.
Last updated: 2024-10-28
Post by andrax on CodeSys Raspberry pi I2C driver not found
CODESYS Forge
talk
(Post)
Sorry, wrong expression. You have a 64bit system, so do I. You can also use the 64bit runtime, but most bib and commands are 32bit and are not properly supported. I had read somewhere that there are problems with I2C. That's why I recommend switching to PI_SL and using the correct gpio.
Last updated: 2024-11-09
Post by reinier-geers on Energie price
CODESYS Forge
talk
(Post)
On a website i can get the energie price. But how does that work in codesys? There is a video of Rest client. But i can find the HTTP library. If i type on my browser : https://enever.nl/api/stroomprijs_vandaag.php?token=ANWB i get {"status":"true","data":"Please provide a valid API token. More information at https:\/\/enever.nl\/prijzenfeeds\/","code":"2"}
Last updated: 2024-12-03
Post by reinier-geers on Energie price
CODESYS Forge
talk
(Post)
On a website i can get the energie price. But how does that work in codesys? There is a video of Rest client. But i can find the HTTP library. If i type on my browser : https://enever.nl/api/stroomprijs_vandaag.php?token=ANWB i get {"status":"true","data":"Please provide a valid API token. More information at https:\/\/enever.nl\/prijzenfeeds\/","code":"2"}
Last updated: 2024-12-03
Post by csu-chris on Colors look different when logged in and running
CODESYS Forge
talk
(Post)
I am running CODESYS V3.5 SP19 Patch 2 (64-bit) I have buttons that are supposed to be either red or green depending on status. When I am logged out the colors look right. When I am logged in and running the colors are completely different and I can't understand why.
Last updated: 2024-12-06
Post by winki on Not Possible to connect using control SL
CODESYS Forge
talk
(Post)
Hello, I used to connect into my gateway using control SL tool 4.13, (it was called Update Linux.) I formated my computer, so today I install the new version of codesys and all package. Now I am not able to connect to my PLC using control SL. It says, check the status. Normally it used to worked perfectly before that.
Last updated: 2025-01-07
Post by timvh on PLCOpenXML Export/Import with Visualisation
CODESYS Forge
talk
(Post)
A Task is a standard IEC 61131-3 object, so logically that you can export the VISU_TASK. A visualization is no standard IEC 61131-3 object, so not compatible with other IEC tools. Just use the standard export / import functionality. These files are not IEC compatible and can only be used in CODESYS. But these do support visu objects.
Last updated: 2025-01-09
Post by jddaigle on Webvisu not supported due to missing browser feature HTML5-Canvas
CODESYS Forge
talk
(Post)
Hello, I'm running the lastest version of Codesys 3.5 SP20 Patch 5, with the lastest version of Chrome. And I still get this "Webvisu not supported due to missing browser feature HTML5-Canvas" fallback with a quite simple webvisu containing some buttons, images, textboxed and a grid. What can I do? is that a configuration to change? Thanks!
Last updated: 2025-01-24
Post by fabiodasilveira on PLC Shell commands via ST Code
CODESYS Forge
talk
(Post)
Thank you, Bingo. I have added the instructions below to the CODESYSControl.cfg file, but they haven't changed anything. [SysSocket] Adapter.0.Name="ETH0" Adapter.0.EnableSetIpAndMask=1 Adapter.1.Name="ETH1" Adapter.1.EnableSetIpAndMask=1 Regarding your second suggestion, could you please expand a bit on that?
Last updated: 2025-03-03
Post by suyash on Version Control
CODESYS Forge
talk
(Post)
Hello, I face issues opening old Codesys 3 program when I am having a newer version installed. Unfortunately since I was forced to format my laptop after an unexpected crash. I lost all the setup files of the older versions. Is there ant where I can download it from? BR, Suyash
Last updated: 2025-03-07
Post by laurits on Max lines of code, codesys CNC ?
CODESYS Forge
talk
(Post)
Testing Codesys CNC. SMC Interpolator Throws me an error if my code surpass approximately 32000 lines of code. (SMC_CNC_INTERNAL_ERROR) What is the max lines of code SMC Interpoltor can handle ? I've been thinking breaking the code up into smaller sections, but that gives me a lot problems later if i want to use "Blocksearch" etc. I need to run approximately 2000000 lines of code.
Last updated: 2025-06-01
Post by installwhat on Opc remote alarms on Linux box
CODESYS Forge
talk
(Post)
It seems that the hmi sl license only works with windows. If i'm happy using web visu, rather than target visu, is possible to use remote opc-ua remote alarms without the hmi sl? Maybe it can be included in a different license that works on Linux? thanks
Last updated: 2025-07-16
Post by davemansell on control loop library IIR filter
CODESYS Forge
talk
(Post)
Hi there i am experimenting with the IIR filter from the control loop library but have been unable to get it to function no matter what inputs I set I get errorID of wrong_configuration (3). Does someone have a working example that they can share. Best regards Dave
Last updated: 2025-07-29
Post by eschwellinger on Codesys Virtual control SL
CODESYS Forge
talk
(Post)
Hi, which CODESYS Version are you using exactly? Either update to 3.5.21.x if you are on 3.5.20.x if not - add a more secure pw. Seems that on adding the login credentials it is mandatory in 4.16.0.0 -to have complianct to password policy seems a bug that the message not occure.
Last updated: 2025-08-06
Post by jcarter on Webvisu Combined Authentication
CODESYS Forge
talk
(Post)
Is there a way to have both a Public No Login Screens with Screens that do require login and File Transfer? My Idea is to have the default page be View Only with a Login Button in the Corner and then Once Logged In you can change settings and download files depending on your user group.
Last updated: 2025-08-28
Post by gseidel on can not new a cam table in codesys V3.5 SP20
CODESYS Forge
talk
(Post)
Hi liai, I tried it with a fresh CODESYS SP21 Patch 2 installation and SoftMotion 4.18, but cannot reproduce the compile errors. Could you please upload a project archive that has the errors? Then I can have a deeper look. https://dl.codesys.com/s/q4KcbKCcZndg6oR Best regards, Georg
Last updated: 2025-09-24
Post by nz-dave on Bool turning on in case stament in wrong state?
CODESYS Forge
talk
(Post)
pretty sure its not. ive done a cross reference and only have one write that sets it to true. Only way i can stop it is to remove the function block call from the main pou that is running said case. its got me stumped:/
Last updated: 2023-12-16
Post by felixal on Codesys automatic Data transfer to USB on rasberry pi
CODESYS Forge
talk
(Post)
Hi all, I am currently working on a project where I need to save data automatically on many diffrent USB-Sticks, which are always plugged in the same USB-Port on a Rasberry PI, but I do not get how I can automatically detect the USB devices Folder Name and save a file there on Linux. Thanks!