Post by dhumphries on How to determine code size CODESYS Forge talk (Post)
I'm trying to determine which Codesys Control license I need, the Control Standard S has all the features I think I'll need, but the code size is limited to 3mb, I created a simple program with only 1 line of ladder logic and a simple visualization with a button and an indicator. When I generate code I get some messages, one indicates that the total allocated memory size for code and data is 2.1mb. Is this metric the correct size of the code? I question the size because it exceeds the allowable code size for the Basic S and Basic M licenses and consumes 2/3 of the available memory for the Basic L or Standard S license. What tool can I use to estimate the size of code as it relates to the runtime license limit?
Last updated: 2024-04-05

Post by jinlee on Dynamic I/Os Mapping CODESYS Forge talk (Post)
Hi guys, Recently, I am working at the Dynamic I/Os mapping feature in Ecockpit or Codesys v3.5. I have been trying the libraries. However, it looks like it will not work as I wanted. I want to build the PLC which can detect all the I/Os itself and from there, I can do something on these channels. For example, the current setup is one digital input card, one digital output card and one analogue input card. Then, I want to add one more card into the setup e.g. one more digital input. Then, wago screen can detect this and we can assign them to tasks for example to control digital output. May I know is it possible ? Kind regards
Last updated: 2023-08-18

Post by talpade on WAGO PLC 200 750-8216 Ethernet connection to Codesys 3.5 CODESYS Forge talk (Post)
Hello, I have the WAGO PLC 200 750-8210. In addition I have downloaded the "WAGO Devices and Libraries 2.0.4.3" and installed the library into the Codesys v 3.5. I then create a new project on Codesys 3.5 and select the device "750-8216 PFC200 (WAGO)" (which I downloaded from the WAGO library). However when I have connected the ethernet cable from the WAGO device to my computer and on my codesys 3.5 i press "Scan Network" on codesys and it does not detect the device. How can I get it to detect the device? (I have put the ethernet cable from my WAGO to the computer, but it does not show the device).
Last updated: 2024-02-05

Post by fontrap on cmDongle Raspberry Pi issue CODESYS Forge talk (Post)
Good morning @eschwellinger, After some research I found out that the problem is the preinstalled CodeMeter on Raspberry Pi. As I mentioned the CodeMeter was installed on the Raspberry because I use a license from other vendor that needs the CodeMeter to be installed. The problem is that when I uninstall the CodeMeter from Raspberry I am able to detect the dongle from CODESYS and everything works as it should be but now the other product can not detect its own license. When I reinstall the CodeMeter I am back to the initial problem. Is there a way to overcome this conflict through CODESYS?
Last updated: 2024-04-24

Post by timvh on Detect "Cancel" Press in FileOpenSave Dialog CODESYS Forge talk (Post)
Maybe there is a better way, but a long time ago I created a test application that worked like this: With a button I opened the dialog and I added a "Input configuration - OnDialogClosed" "Execute ST-Code" action to this same button which called the following Function when the dialog was closed: F_OnFileDialogClosed(pClientData); Below this Function which handled the result: // This function is called from the visualization when the dialog is closed. FUNCTION F_OnFileDialogClosed : BOOL VAR_INPUT pClientData : POINTER TO VisuElems.VisuStructClientData; END_VAR VAR dialogMan : VisuElems.IDialogManager; FileOpenCloseDialog : VisuElems.IVisualisationDialog; result : VisuElems.Visu_DialogResult; _sFileName : STRING(255); END_VAR // the DialogManager is provided via the implicitly available VisuManager dialogMan := VisuElems.g_VisuManager.GetDialogManager(); IF dialogMan <> 0 AND pClientData <> 0 THEN FileOpenCloseDialog := dialogMan.GetDialog('VisuDialogs.FileOpenSave'); // gets the FileOpenSave dialog IF FileOpenCloseDialog <> 0 THEN result := FileOpenCloseDialog.GetResult(); // gets the result (OK, Cancel) of the dialog IF result = VisuElems.Visu_DialogResult.OK THEN // Original code gvlFile.FileListProvider(); _sFileName := CONCAT(gvlFile.FileListProvider._stDirectory, gvlFile.FileListProvider.stFile); // do something with this file name... END_IF END_IF END_IF
Last updated: 2023-09-19

Post by riccardo on VisuElems.CurrentUserGroupId is not stable CODESYS Forge talk (Post)
GoodMorning everyone. I have a system that, in case of alarm, have to block. When the operator logs in must have to acknoledge the alarm and should operate in the system freely. To perform this I detect the logged User by (VisuElems.CurrentUserGroupID <> 0) with a similar code to the the following: PROGRAM AlarmMngt VAR alarm : BOOL:= FALSE; Ack : BOOL:= TRUE; PushBottonOpening : BOOL:= FALSE; Valve : BOOL := FALSE; Flag: BOOL := FALSE; END_VAR IF alarm AND Ack AND (NOT Flag) THEN valve := FALSE; PushBottonOpening := FALSE; Ack := FALSE flag := TRUE; ELSIF (NOT alarm) AND Ack THEN flag := FALSE; END_IF (* if the system is in alarm but there is a logged operator that acknowledge the alarm the system allows the valve opening.*) IF (VisuElems.CurrentUserGroupID <> 0) AND Ack AND Alarm AND PushBottonOpening THEN Valve := TRUE; ELSIF (VisuElems.CurrentUserGroupID = 0) AND Alarm THEN valve := FALSE; END_IF The problem I have is in the last 5 lines of the code: Even if there is a logged in user, the GroupID variable is subjected to a refresh that cyclically set for an instant it to 0 and this close the valve making difficult to the user to work Now I solved it creating a time hysteresys cycle but it is not a good solution. Someone is able to explane me why the GroupID variable is sobjected to this refresh and how to stabilize to avoiding it? Thank you in advance, Riccardo
Last updated: 2023-11-10

Post by manuknecht on Detect "Cancel" Press in FileOpenSave Dialog CODESYS Forge talk (Post)
Thanks for your response! It seems like the VisuElems library has updated functions to the ones you used but apparently these older ones still work, even if I couldn't find them in the library documentation and they are also not suggested automatically by Codesys (when using Ctrl + Space). However, its precisely what I was looking for and it works. Thanks!
Last updated: 2023-09-20

Post by felixal on Codesys automatic Data transfer to USB on rasberry pi CODESYS Forge talk (Post)
Hi all, I am currently working on a project where I need to save data automatically on many diffrent USB-Sticks, which are always plugged in the same USB-Port on a Rasberry PI, but I do not get how I can automatically detect the USB devices Folder Name and save a file there on Linux. Thanks!
Last updated: 2024-01-03

Post by denizerm on Deploy Control SL cant find Podman CODESYS Forge talk (Post)
I found something that might be the main cause for this: /etc/os-release features the ID=debian entry on my reference system; When i temporarily override my DUTs os-release to feature ID=debian or similar its able to detect Podman. Is there a way to fix this behaviour?
Last updated: 2025-10-24

Post by s1ack on Request a dark mode for CODESYS CODESYS Forge talk (Post)
and other colors have to be licensed? Introducing Code-Based Licensing Code Basic S: White text w/ grey background (ST only) Code Basic M: White text w/ dark gray background (ST Only) Code Basic L: White test w/ black background (ST Only) Code Standard S: 2 Colors of light syntax highlight colors w/ black background. (ST Only) Code Standard M: 4 Colors of light syntax highlight colors w/ black background. (ST only) Code Standard L: 6 Colors of light syntax highlight colors w/ black background. (ST only) Code Performance S: 2 Colors of light syntax highlight colors w/ user definable background. (Entire IDE) Code Performance M: 4 Colors of light syntax highlight colors w/ user definable background. (Entire IDE) Code Performance L: 6 Colors of light syntax highlight colors w/ user definable background. (Entire IDE) You get the gist... I used to be a big fan of CoDeSys. Recent re-entry after 5 years away, not so much.
Last updated: 2024-11-15

Post by youness on No source code available (cip object) CODESYS Forge talk (Post)
Hi yotaro, hope your problem was resolved. I had the same, but with an other library title. This exception is not detected during compilation, but rather at a given position in the program (when switching to a given visualization). Although the exception is generated at this point, it does not involve the visualization in question. This error is due to one of 3 reasons: 1) A division by zero somewhere: The program is able to detect divisions by zero at compile time. But in the case of a variable, which takes a valid value at init and changes to 0 at a later stage. 2) An invalid pointer: (either because it has a value of 0, or because it points outside the memory reserved for the program) is being dereferenced. Locate any pointers or interfaces you have in the code and check them - you should also be wary of mixing inline modifications and pointers. 3) Array overflow: Generally when a processing operation is executed outside the array's definition range. Example: a write loop with n iterations is executed on an array of dimmension n-1. On the other hand, the error message may not appear. In the latter case, the error may have fatal consequences, as the overflow has induced writing to potentially forbidden memory areas. This problem can be explained by the fact that it's not always the adjacent memory areas of PLC_PRG that are overwritten, but the memory areas that are randomly allocated to the array during compilation. In this case, however, there is no entry in the log, so you need to integrate the "Implicit Check function", which checks the line of code generating the error. To integrate this functions, click on Application --> POU for implicit controls Regards,
Last updated: 2024-07-16

Post by alexgooi on How to protect library project? CODESYS Forge talk (Post)
Hi aniket-b, If you save the library as a compiled library you are not able to see the source code. When the end user tries to view inside the object, CODESYS will give a notification that the source code is missing, see attachment. In short if you don't send the source code, it will not show.
Last updated: 2024-01-25

Post by aconley on Static Code Analysis CODESYS Forge talk (Post)
I'm using CODESYS 3.5 SP16 Patch 6. I would like to incorporate static code analysis as part of our CI/CD pipeline. 1. Is there a way to execute the static code check from the command line or python script? 2. If you can't do it from the command line, is there a way to export the results from the application?
Last updated: 2024-02-15

Post by arslan on G Code Position Shifting CODESYS Forge talk (Post)
Dear friends, I have a issue that. I would like to give a zero offset of any axis in G-Code by G54 from PLC code as below demonstration. N000 G00 X0 Y0 Z0 N010 G54 (offset from PLC) N020 G01 X0 Y0 Z0 . . How to fix it! BR
Last updated: 2024-05-02

Post by astutoski on No Motion with SM3_RaspiStepper (GPIO 23/24 Show No Pulses) CODESYS Forge talk (Post)
Hi everyone, I’m completely new to CODESYS and have been teaching myself. And i Want to control an Axis using SM3RaspiStepper. Following the example on the RaspiStepper home page, I set up an axis through a POU and tied the SMC_StartupDrive (Visu) template to my axis instance (sud). Unfortunately, the motor never moves and I don’t see any pulses on the PULSE pin (GPIO 23). Hardware -Raspberry Pi 4 B -Nema 17 stepper motor -A4988 stepper driver (EN pin permanently tied to GND) Software / Runtime -CODESYS 3.5 SP21 Patch 1 – Raspberry Pi runtime (demo) -SoftMotion in demo mode -Package: SM3_RaspiStepper 0.0.0.6 Axis parameters: Pulse pin GPIO 23 Direction pin GPIO 24 Enable pin 0 (unused) Disable pin 0 (unused) Whether I start the axis from the visualization template or through Online Config Mode, the motor never spins. In Online Config Mode I press Power β†’ the state changes from Standstill to Discrete_Motion, but the motor shaft is still locked and no step pulses appear on GPIO 23 (checked with a scope). I can provide screenshots of the Visualization, PLC logs, or wiring pictures if that helps. Any ideas on what I might be missing? Happy to provide screenshots, project files, or scope captures if that helps. Thanks in advance!
Last updated: 2025-06-25