Post by r-niedermayer on Issue with WebVisu on Raspberry PI CODESYS Forge talk (Post)
Regarding to your application: When clicking in the web visualization, the boolean variable will be tapped for both buttons. The LED in the web visualization lights up as long as the variable is true The used variables should come from the GVL, ad/or thePLC_Prg. We see no difference or problem in both projects: You have created a visuelement Push button a a tapper, that is supposed to control the variable in this way as expected. This is also reflected (switching Bool from false to true) in the program code, as well as in the (GVL declared) variables. Wherever the misunderstanding comes from: no, this is not memory or license related. Our best guess: it is probably more of an applicative/conceptual implementation.
Last updated: 2024-04-11

Post by m83coding on Raspberry Pi Codesys SPI Master CODESYS Forge talk (Post)
Hello, I am trying to control shift registers 74HC596 and 74HC165 via Raspberry PI with SPI interface. So far I did it with a Microcontroller and now I wanna upgrade my Projekt with Raspberry Pi and Codesys Software to be more flexible. I tried to adapt PiFace Function Block to just send or recive a 8 bit via SPI interface of the my Raspberry Pi. With following code (see attached screenshots) * PLC_PRG * PiFaceDigital * PiFaceDigital.write8 * PiFaceDigital.read8 I have a signal at SCK and MOSI pin of the PI, so far so good. But I really struggle with the unterstanding of the code. Is there some detailed description of each line of code? Or is there somebody in the community who can explain each line of code? Or is there a more simple way to send / recive 8 bit via SPI? Manuel
Last updated: 2024-04-23

Post by reinier-geers on License problem gateway CODESYS Forge talk (Post)
Epis doesnt want Softmotion. I thought it was about the price. If it was possible it would be working already and i dont need an extra licence. Thats the problem of codesys. The software is running but hangs on its license. Epis made it posible to see the stick. I can see the license. Softmotion is there from 3.5.14.Xx Like is said And Motion control is alrady posible 15 year ago. And i only need a Sync of 2 drives. I want a good solution not a refund. Dont point to the manufacturer. The software is made by 3s not by epis .
Last updated: 2024-04-29

Post by fpawlak on KNX SL on stock PFC200 firmware CODESYS Forge talk (Post)
Hi All. Is it possible to use CODESYS KNX SL on stock Wago firmware (Codesys version, not e!Cockpit). I have Wago 750-8212 with firmware 0.4.04.03(26). When I tried to run 'KNX SL' or even 'Device Reader', I have got [FATAL ERROR] Unresolved reference: 'CODEMGETCONTENTBYFIRMCODE3' [FATAL ERROR] Unresolved reference: 'CODEMGETCONTENTBYFIRMCODE2' [FATAL ERROR] Unresolved reference: 'CODEMGETCONTENTBYFIRMCODE2' What probbalby means that there is no running CodeMeter component on PLC. I have checked /etc/codesys3.d/CODESYSControl.cfg [CmpWebServer] WebServerPortNr=58080 [CmpSecureChannel] CertificateHash=86ccf31839a098ee32067179e26600f1bd6b36f8 [CmpUserMgr] AsymmetricAuthKey=a9d38381e75bbf1bbfc8749e97f536f68238a2ce So the question is if I can somehow add Codemeter to stock firmware? Or should I switched to CODDESYS Control for PFC200 SL or application-base runtime licence?
Last updated: 2024-05-23

Post by stewnguth on New License not working. CODESYS Forge talk (Post)
Hey there, I am pretty new to the codesys space, but I got a codesys control basic M license for my raspberry pi that isntalled with no problem yesterday. Today, I went to install the visualization M locense as well because I went over the variable limit and am getting a "servernotfound" error in codesys when attempting to activate. I also tried to follow the advice in some other threads and install using a license request file on the web interface but am getting a message saying "An internal error occured" when attempting to install the license. Can anyone help me get this up and running? Thanks for your time.
Last updated: 2024-05-23

Post by damian177 on CM4S GPIO's in Codesys CODESYS Forge talk (Post)
Hi, I am running my application on device based on Compute Module 4S (Cortex-A72 (ARMv8) 64-bit ). On this device I installed RPi Runtime in 4.11.0.0 version. In my project I use device: Codesys Control for Raspberry Pi 64SL and my project works, but I actually do not have acces to all GPIO's , because GPIOs Compute Module is available only in 3.5.16.0 version and it doesn't work. Properly work GPIOs B+/Pi2 but using this device I do not have acces to all GPIO's in CM4S. Anyone of can tell me how add GPIOs Compute Module 4.11.0.0 to my project ?
Last updated: 2024-05-28

Post by fajean on CODESYS control on RPi starts, shortly runs, then exits CODESYS Forge talk (Post)
4.11 appears to solve the problem. Thanks for your help. I had first installed the 64-bit version of RPiOS, but looking at various posts and the product's page on the store which only lists 32-bit compatibility, I downgraded to the 32-bit version. I did this before trying 4.11, and it did not solve the problem. Thus my working system is 32-bit, and I am wondering if I can go back to 64-bit or not. An 64-bit OS is not listed as compatible on the store's web page, but when installing there actually is a 64-bit version listed (automatically chosen when installing on 64-bit, but otherwise greyed out). Is 64-bit supported and the website is out-of-date, or is that some kind of work-in-progress?
Last updated: 2024-06-13

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by mborchert on PFC100 Error "Bus not running" CODESYS Forge talk (Post)
Hello, i currently want to use a wago 750-8102 with the "codesys control for pfc100" runtime. I want to add the devices connected to the internal pfc100 bus via the "search devices" tab. This was reccommended in the following thread: https://forge.codesys.com/forge/talk/Deutsch/thread/7701332199/ But whenever i try to search for devices codesys just doesnt find anything and i cant close the "search devices" window. Has anyone got an idea what the problem might be? I already tried adding the devices connected to the pfc100 manually but the bus just doesnΒ΄t start. best regards Moritz
Last updated: 2024-06-17

Post by kuegerls on SysProcessExecuteCommand2 and CANopen Device CODESYS Forge talk (Post)
Hello, CODESYS Control is running on my RevPi, and my system communicates over a CANbus with a master using the ConnectCan module (Slave - CANopen Device). The communication works perfectly fine so far. However, as soon as I call a Python script with "SysProcessExecuteCommand2" that creates a CSV file and executes without errors, the master does not adopt any changes to the Transmission Process Data Objects (TPDOs). I don't quite understand what one has to do with the other, and perhaps someone can help me with this. Here is my script call: SysProcess.SysProcessExecuteCommand2(pszCommand:='python /home/pi/test.py', pszStdOut:=sCMDOutput, udiStdOutLen:= SIZEOF(sCMDOutput), pResult := ADR(eResult)); Thank you in advance! Best regards, Stefan
Last updated: 2024-06-20

Post by adaml on ScriptEngine - execute "Export -> Bootproject and firmware (SD Card)" from python CODESYS Forge talk (Post)
Hi everybody, recently I was checking how many time consuming manual tasks I can perform with python scripts through ScriptEngine. I have in the project many devices and currently I export bootprojects for them by right clicking on Application, then go Export -> Bootproject and firmware (SD Card) and then point folder where files should be exported. It's fine if project has few devices, but I have some of them with over 30 devices and manual clicking like that is very time consuming. How can I do it with python script? So far I found "create_boot_application" method from Application object (taken by projects.primary.find('Application', True)) but it only generates .app and .crc file instead of full structure to store on SD card (FIRMWARE, USERDATA, SDCARD.INI, Version, Version.txt.sig). Should I use some method to control user interface? Best regards, Adam
Last updated: 2024-07-05

Post by yannickasselin on codesys VLAN tagging CODESYS Forge talk (Post)
Hi, I am looking for exactly the same thing. I would think that using a layer 2/3 managed switch should work but I am not convinced. I would like to test it in order to see if it would be possible to run many Codesys Docker instances on a server and run only 1 ethernet cable from the server to a managed switch closer to the machines beeing controlled instead of having to run multiple long ethernet cables. I was going to buy a managed switch in order to test it but I want to first make sure it is possible and I want to figure out exactly what kind of switch I would need. Is this even possible? I think this is a feature that would be very useful paired with "Codesys Virtual Control SL". Thank you
Last updated: 2024-09-07

Post by timvh on Clarifications regarding the appropriate runtime system to use CODESYS Forge talk (Post)
If you are not using any specific Raspberry Pi functionality, then probably the "universal" Control Linux ARM SL is the approriate runtime to run on the Pi. For the license it doesn't matter which runtime version you choose, because this is not hardware based anymore, but application based. Best is to use the latest version of CODESYS. To determine which license you need, double click on your device, go to the tab License metrics.... Generate the code for your application and see which license you need based on the metrics of your application.
Last updated: 2024-09-24

Post by pernockham on Linking to IO during runtime with hot swap? CODESYS Forge talk (Post)
I have a project where a single PLC shall control multiple nodes (up to 10 units?) with IO connected through profinet. Ideally each node should be identical however with time I see situations were different setups/configurations will be used. Codesys PLC (GVLs) |Profinet | |--PNIO-node-1--| | | AIO, | | DIO, | | CNT etc. | |--PNIO-node-2--| | | AIO, | | DIO, | | CNT etc. Ideally I think of a configuration through yaml/xml-files (the assignment/linking of the profinet nodes towards GVL-variables in the PLC as well as scaling, channel configration etc.). Would be grateful if someone could suggest library/-ies that can handle the following: - Verify what IO is connected to a device/node. - Hot-swap/assign link for IO towards GVLs, either automatically or through a HMI.
Last updated: 2024-10-11

Post by siscu on Raspberry i2c master device CODESYS Forge talk (Post)
I want to implement an extended I2C master for Raspberry Pi Control. I was hoping for it to be as easy as creating a library with a FB that extends i2cMaster and associating it with a device following the forge drivers documentation, but I haven't managed to make it work as the driver behaves only as an i2c slave. I'm thinking this is because the forge forum only talks about extending i2c, and the master portion is omitted since most users won't want to add a custom one. I'd like to know if I'm doing something wrong. Is it really possible to make an I2C master extension device? If so, are there public examples we can check out? Any info on this topic will be appreciated.
Last updated: 2024-10-16

Post by timvh on Modbus TCP & RTU with Control for Linux SL CODESYS Forge talk (Post)
RS485 doesn't seem very logical to use in VPLC's in my opinion. I also don't know if this is supported.... But for TCP/IP, I think you still need to configure the Nic settings. See the attached png. In my case enp6s0. When changing this setting, restart the VPLC. What is really nice, is that you don't have to configure the IP address setting in Linux. By setting the Nic to a certain IP address in the CODESYS instance configuration, this is automatically done for you. I only tested this with EtherCAT, but I guess this works the same for Modbus TCP/IP.
Last updated: 2024-10-23

Post by gediminas on Datasource OPC UA client system failure CODESYS Forge talk (Post)
I am using CODESYS v3.5 SP20 Patch 3 / Control for BeagleboneBlack SL v4.13 and after some time the OPC UA Server crashes. However, Runtime still works without any issues. The events leading up to the OPC server crash are the most suspicious: 1) Mutex deadlock detected - owner thread died, and 2) Runtime received SIGABRT. And it seems very similar with this topic except used versions - issues should be fixed with previous SP's. I can't seem to find any information about these events. Need some pointers in the right direction on how I can fix this problem.
Last updated: 2024-10-25

Post by ben1 on How to write multiple coils (Modbus FC15) CODESYS Forge talk (Post)
If I am understanding what you are saying, then yes that would be your problem. I would create an array of bools on the client side for the transfer and try that. Or if client can't be changed then use words on server and unpack. But I am not sure if you or I are mis interpreting but it sounds a bit jumbled. I don't know what you have control of, but, if you are turning on BITS in the server, you should write to BITS in the client with a Function 15. If you are writing to WORDS in the server, you should write to WORDS in the client with a Function 16.
Last updated: 2024-11-17

Post by milosfejgl on Codesys Licenses - How to reload them after updating the Raspberry Pi OS CODESYS Forge talk (Post)
We use several control units running on Raspberry Pi, programmed using Codesys software, with multiple licenses stored as soft containers. We are planning to update the SD card image of the Raspberry Pi to a newer OS version. However, we are concerned that this process might result in the loss of our soft container licenses. Is there a way to temporarily deactivate the license so that it can be reactivated on the updated system? Alternatively, what would be the best method to preserve the licenses during the update? Thank you in advance for any responses!
Last updated: 2025-03-13

Post by s1ack on Wago PFC200 Ethernet / IoDrvEthernet Issue? CODESYS Forge talk (Post)
CODESYS Control for PFC200 4.13.00 CODESYS IIoT Libraries SL 1.11.0.0 Application Based License: CODESYS Control Standard M I have (2) projects with similar code base and both using Wago PFC200. On the second project I am seeing 2 things that I have not been able to resolve: 1) Errors in the log under the Ethernet Item: IoDrvEthernet: [PCI\E1Q51CE62] Could not be found on target! Please check the Ethernet settings. 2) Exception for CPU Load. "Processorload watchdog: plcload=100, maxplcload=95" I have slowed down cyclic tasks on this project, even though on the first project there is actually more code - and it does not exhibit this behavior. In looking at the CPU loading via Linux 'TOP' command there appears to be 20% idle. So plenty of headroom (my opinion). In an effort to troubleshoot I have duplicated the target hardware on my bench. It ran overnight without a CPU load exception. On the test system, I have tried (3) version of the ethernet device. 3.5.16.0 3.5.17.0 and 4.2.0.0 Presently the log does not show the error, but status says the module reports an error. I really do not know if this issue is related to the CPU load exception. The issue does not appear to effect ethernet communications (ModbusTCP or SNMP or Webvisu or PuTTy into Linux Shell). On my test bench I have ModbusTCP slave simulators for all ModbusTCP slaves, but only (1) of the (5) SNMP devices present.
Last updated: 2025-01-21