Post by swol on HTML 5 - Controls -> Change Content-Security-Policy settings
CODESYS Forge
talk
(Post)
Sorry for being late to the party... so it is not possible to use the webbrowser tool to display external websites in a visu anymore? As it is not possible to simply "adjust the ContentSecurityPolicyIncludeTrustedOrigins setting in the automatically generated webvisu.cfg.json file" as stated in the docs? We need to display data read from a Raspberry Pi (part of our computer network) in our webvisu. We used to do it by entering the Pi's IP address as the URL variable in the webbrowser element but now (I don't know since when, I'm new on the job) "The page’s settings blocked the loading of a resource (frame-src) at 'IP address' because it violates the following directive: “default-src 'self' 'unsafe-inline'”. What are the options for displaying the data?
Last updated: 2025-11-11
Post by mondinmr on Frustration-Fueled Feedback on Project File Management and Git Integration
CODESYS Forge
talk
(Post)
Good day, I’m writing this message out of frustration regarding the current way project files are saved as encrypted XML and single-file format in CODESYS. I find this approach to be quite tedious for several reasons: Limited Access to Structured Text: Not being able to access Structured Text (ST) externally makes it impossible to work with alternative editors like VSCode. Tools like VSCode are incredibly responsive and feature advanced systems such as GitHub Copilot, which would be a real game-changer when working with ST IEC. While CODESYS works well for small code snippets or debugging, when the codebase grows, switching to VSCode to boost productivity becomes essential, and copy-pasting between environments is a cumbersome workaround. Poor Integration with Git: This file format also makes it very difficult to integrate effectively with Git. I have tested the internal demo, but for advanced merges, it is unusable. Without properly formatted plain text, it’s impossible to leverage the vast ecosystem of external tools around Git that allow smooth merges in heterogeneous teams. File Corruption on Network Drives: I often work from multiple locations with shared network drives. When the development environment saves a file and something goes wrong midway (which can occasionally happen when using VPNs and network drives), the entire project becomes irrecoverable. There’s no way to cancel the save process, and the development environment freezes. This has happened to me at least four times over the past two weeks, and one of those incidents cost me an entire day of work. All of this is particularly disappointing because I truly believe that the libraries, runtime, and overall work done by CODESYS are exceptional. I find it fantastic that there is a platform allowing development of PLCs and control systems using OOP, which is a huge advantage in modern control engineering. I apologize for the rant, but this issue has been extremely frustrating. Best regards.
Last updated: 2024-10-15
Post by breiter on Frustration-Fueled Feedback on Project File Management and Git Integration
CODESYS Forge
talk
(Post)
Hi, supporting a text based storage format is on our roadmap, see https://www.codesys.com/the-system/releases-updates-lifecycle/release-plan-roadmap.html It will be an Add-On feature called "File Based Storage" for the professional developer edition. Structured text POUs will be stored as plain text. Other graphical languages will remain in an xml format. You will be able to switch the storage type for projects. Certain workflows will become easier this way. Nevertheless restrictions will remain because of CODESYS specific storage logic (for example how methods below function blocks are stored as file). So merging using our Git Integration Add-On remains the recommended workflow. A workflow involving Visual Studio Code as the main IDE is not supported. Simply because many topics like library management, task configuration or fieldbus configurators are not available for VS Code. A PLC project is a lot more than just some ST POUs. Best Regards
Last updated: 2024-10-16
Post by dominggus on when going online, stuck on "Syncing file "visuelemsdatetime.tl_datetime.txt"
CODESYS Forge
talk
(Post)
Hi, We are currently using a Raspberry Pi 4 CM4 module in a EdgeBox RPI 200 - Industrial Edge Controller running the latest CODESYS Runtime Package 4.11.0.0. On the PC (actually an Intel Macbook Pro running Windows 10 in Parallels) we run CODESYS V3.5.19.50. Yesterday end of day when I was about to logoff and head home, I wanted to send the latest build to the Raspberry I clicked the Login button to compile a new version and then sync the application and all the files, it get's stuck on the last file to sync (see attached screenshot). This takes eternally, although sometimes, when I use my SFTP client (Cyberduck) and go into the raspberry and refresh the directory /var/opt/codesys/PlcLogic/visu/, or when I open the actual file visuelemsdatetime.tl_datetime.txt, it gets un-stuck (forcing a refresh, which might fix the syncing issue) and CODESYS continues and I can click the Start button to start the application. But this SFTP force refresh trick does not always help either... What could be the issue here? network connectivity? Can someone please help me out?
Last updated: 2024-03-02
Post by trusty-squire on SysProcessCreate2 on Linux runtime
CODESYS Forge
talk
(Post)
Hi, I'm trying to launch a continuously running python script from Codesys and monitor the script status inside the Codesys runtime (running on a Linux enviroment). For now I'm testing with the below to emulate a continuously running Python script: #test.py i = 0 while True: i += 1 I'm able to successfully run the script using SysProcessExecuteCommand2 (I can see the Python process running in the task manager). However, this "freezes" the Codesys execution of the task - it sits on that command and will not continue until the Python script ends. I've proven this works by using the task monitor to kill the process, then Codesys continues on happily through the task. What I want to do is use SysProcessCreate2 to set up the Python script as a background task and monitor the process using SysProcessGetState. This always results in the error "ERR_OPERATION_DENIED". I know that I'm able to execute commands (as above), so my config should be correct. Is SysProcessCreate2 functional on a Linux environment? Is there something in the config file I'm missing? Here's my "working" code that uses SysProcessExecuteCommand2: VAR bTest : BOOL; sCommand : STRING := '/usr/bin/python3 /var/opt/codesys/PlcLogic/Application/test.py'; refCommand : REFERENCE TO STRING REF= sCommand; sOutput : STRING; refOutput : REFERENCE TO STRING REF= sOutput; result : RTS_IEC_RESULT; END_VAR IF bTest THEN SysProcessExecuteCommand2( pszCommand:= refCommand, pszStdOut:= refOutput, udiStdOutLen:= SIZEOF(sOutput), pResult:= ADR(result) ); bTest:= FALSE; END_IF And here's the code that always results in the ERR_OPERATION_DENIED error: VAR bTest : BOOL; sApp : STRING := '/usr/bin/python3'; sCommand : STRING := '/var/opt/codesys/PlcLogic/Application/test.py'; refApp : REFERENCE TO STRING REF= sApp; refCommand : REFERENCE TO STRING REF= sCommand; hResult : SysProcess.RTS_IEC_RESULT; hHandle : SysProcess.RTS_IEC_HANDLE; END_VAR IF bTest THEN hHandle := SysProcessCreate2( pszApplication:= refApp, pszCommandLine:= refCommand, ulFlags:=SYSPROCESS_CREATEFLAG_HIDDEN, pResult:= ADR(hResult) ); bTest:= FALSE; END_IF Here's the relevant section from the config file at /etc/codesyscontrol/CODESYSControl.cfg: [SysProcess] Command=AllowAll Appreciate any support or ideas. Thanks!
Last updated: 2025-03-16
Post by rossanoparis on After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working
CODESYS Forge
talk
(Post)
Hello at all. After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working. I'm not able to read or write files from the PLC application. Before this upgrade all worked fine. I've read this thread [ https://forge.codesys.com/forge/talk/Engineering/thread/3da9ded84e/ ] Despite I followed that indications I couldn't get my code working again. Perhaps I'm missing something or I didn't understand how to use placeholders at all. Is there a different syntax to use for "SysFileOpen" in order to use placeholders? Thanks in advance for your help. Information Compiler: CODESYS V3.5 SP19 Patch 2 Runtime: codesyscontrol 4.9.0 HW: KUNBUS RevPi Connect S Below the paths I want to access (The entire CODESYSControl_User.cfg file is attached) [SysFile] PlaceholderFilePath.1=/home/pi/hpca/bin, $hpcabin$ PlaceholderFilePath.2=/home/pi/hpca/cfg, $hpcacfg$ PlaceholderFilePath.3=/home/pi/hpca/logs, $hpcalogs$ PlaceholderFilePath.4=/home/pi/hpca/resources, $hpcares$
Last updated: 2023-08-22
Post by micik on How to generate an "ENI" file
CODESYS Forge
talk
(Post)
That really depends on this third party software you want to use. It is possible that .xml file generated with "Generate EtherCAT XML" will not be recognized as valid ENI file. Anyway, "Generate EtherCAT XML" command is not available through standard menus and needs to be added via Tools->Customize and then Add Command. You'll find it under "Devices" section. If you provide more info, we might be able to help you further.
Last updated: 2024-08-09
Post by yann2021 on Execute a .py file with Codesys
CODESYS Forge
talk
(Post)
Hello, I have a Raspberry Pi 3 which has a printer connected to his USB port. I have a PiFace Board on the Raspberry. I have a python script file (.py) to print a logo + a text. The script is working because when I execute it from the Raspberry terminal it works. Now, when I push a button on the PiFace I would like to execute the python script file to print. How can I do that ? Many thanks for your help and advices!
Last updated: 2025-08-26
Post by youness on CSVReaderInit returns error : INVALID_HANDLE
CODESYS Forge
talk
(Post)
I have Already the same problem when i'm trying to write data more than 10 times in the same file. In fact, i send my data periodicaly to a file that i configured to have permission of W/R in my CodesysContol.cfg. When the Error occurs, i must reboot my machine to success. It means that the problem isn't realted to a limitation of size, but a problem in the function supposed to handle the file. totorovic : allow me to know if you've found a solution to your problem. Thanks.
Last updated: 2025-11-26
Post by t-probst on Strong Private Key Protection for Encryption Certificates
CODESYS Forge
talk
(Post)
Hello, We are trying to implement an automated method of adding of a certificate and private key to the Windows certificate store for encrypting CODESYS projects. We want to do this so that users do not have to deal with details of certificates at all and to prevent user error. We are keen on enforcing strong private key protection since it ensures that a password is required for the certificate to be used to decrypt a CODESYS project. When we add a certificate to the certificate store and enable strong key protection using the Microsoft Management Console Certificates snap-in, it works as expected. However, through this method the user may mistakenly not enable strong private key protection. For the certificates we create programmatically (using Microsoft’s Cryptography Next Generation API in .Net 7) bag attributes are added to the certificate and key by the API. These bag attributes are as follows: Bag Attributes localKeyID: 01 00 00 00 subject=C = xx, ST = xxx, O = xxx, OU = xxx, CN = xxx issuer=C = xx, ST = xxx, L = xxx, O = xxx, OU = xxx, CN = xxx -----BEGIN CERTIFICATE----- [encoded certificate] -----END CERTIFICATE----- After using this certificate with bag attributes to encrypt a CODESYS project, it can’t be decrypted, showing this error: "The specified project could not be loaded. Possible reasons might be: - The project file is corrupted or invalid - The project has been saved with a newer version of the programming system. If this is the case, you can open the project in the corresponding version. Choose "Save as..." with the appropriate storage version, and retry again. - You may not have the necessary permissions to lad the project" We know that the bag attributes are causing the issue because if we manually edit the certificate file to remove them before using the certificate to encrypt a project, the project can be decrypted as expected. However, we are unable to automatically enforce strong key protection using this method. Here is a link to a StackOverFlow question that we have posted recently for this issue: https://stackoverflow.com/questions/76922355/enforcing-strong-private-key-protection-for-x509certificate2-objects-in-net-mod Any help is greatly appreciated.
Last updated: 2023-08-22
Post by josul on Web Client HTTPS Communication Issue
CODESYS Forge
talk
(Post)
Web Client Library Documentation Company: 3S - Smart Software Solutions GmbH Title: Web Client Version: 1.0.1.7 Categories: Application|Utils Namespace: WEB_CLIENT Author: 3S - Smart Software Solutions GmbH Placeholder: WebClient I encountered an issue using this library above. Note it is now part of Codesys IIoT Libraries SL in the form of Web Client SL, but I am not using this version. I was sending Content-Type: application/json, HTTP POST using a HTTPS URL. No issue observed initially, successful operation. At some point operation stopped and the codesyscontrol.log file started to accumulate errors: ERROR: TlsCreateContext2: Failed to save context. An application reset failed to resume operation and I was unable observe any TCP connection forming to a destination port 443. The error appeared as a TCP_INIT error. I can find no details as to what may have happened or why a reset of the PLC application did not resume operation. Testing with a curl operation proved to be successful, so I am confident there was no fundamental networking issue preventing a TCP connection forming. The solution was to reboot the hardware itself, but this is not satisfactory in the long term. Is there any description of the TLS error I received? Is there any suggestion here that there might be an issue with certificates? Any advice or information is appreciated.
Last updated: 2025-06-05
Post by ragarcia on Error while using UpdateConfiguredIPSettings to change IP address
CODESYS Forge
talk
(Post)
Hello everyone, I am trying to change dynamically by code the IP address of a Weidmuller controller. So I am basically using IoDrvEthernet library to use UpdateConfiguredIPSettings function but I am getting constantly the 'INVALID_STATE' error. Even though I am following a procedure it should work: * First I added on the config file of codesys the following: [SysSocket] Adapter.0.Name="eth0" Adapter.0.EnableSetIpAndMask=1 Adapter.1.Name="eth1" Adapter.1.EnableSetIpAndMask=1 * Secondly I am first disabling the ethernet interface by using Ethernet_0.Enable = FALSE and then executing DED.Reconfigure. After that, I run the Ethernet_1.updateConfiguredIPSettings Code: Ethernet_1.Enable:= EnableDisable; Reconfigure(xExecute:= TRUE, itfNode:= Ethernet_1, xError=> ErrorReconfigure, eError=> ErrorCodeReconfigure); IF Reconfigure.xDone THEN ErrorCodeIP:= Ethernet_1.UpdateConfiguredIPSettings(IPAddress:= newIP, SubnetMask:= newMask, Gateway:= newGW); END_IF IF Reconfigure.xDone OR Reconfigure.xError THEN Reconfigure(xExecute:= FALSE); END_IF Ethernet_1.Enable:= TRUE; Reconfigure(xExecute:= TRUE, itfNode:= Ethernet_1); IF Reconfigure.xDone OR Reconfigure.xError THEN Reconfigure(xExecute:= FALSE); END_IF Can someone help me? Thank you. All I am trying is to find a way to change dynamically with code, the IP addresses of my controller (2 ethernet ports).
Last updated: 2023-12-11
Post by janderson on OPC UA Server limitations, large array crashes runtime
CODESYS Forge
talk
(Post)
when using an array of structs, the runtime crashes. but when using an array of LREALS, it'll do 100k at least
Last updated: 2023-08-23
Post by tvm on Web Client (HMI) Disconnects from Webvisu (Weidmuller u-OS)
CODESYS Forge
talk
(Post)
We have seen this kind of thing before. I have two questions: 1. What kind of HMI are you using? 2. When this happens, are you able to connect using https, on port 8089?
Last updated: 2023-09-06
Post by wehling-h on Troubles with using CAN API
CODESYS Forge
talk
(Post)
Hi together, I'm using a 11bit driver system which seems to work well so far. May someone here knows if i have to configure a singleID for each message i like to receive and evaluate?
Last updated: 2023-09-11
Upgrading CODESYS runtime from v4.7 to v4.9 using a bash script leads to lose the licences stored in the soft container
CODESYS Forge
talk
(Thread)
Upgrading CODESYS runtime from v4.7 to v4.9 using a bash script leads to lose the licences stored in the soft container
Last updated: 2023-09-19
When using the Element Collections library, is there a proper way to remove a dynamically created collection from memory?
CODESYS Forge
talk
(Thread)
When using the Element Collections library, is there a proper way to remove a dynamically created collection from memory?
Last updated: 2022-09-08
Setting up the "Visual Studio Code" debugging environment (using .NET debugging) for use with the ScriptEngine API in Python.
CODESYS Forge
talk
(Thread)
Setting up the "Visual Studio Code" debugging environment (using .NET debugging) for use with the ScriptEngine API in Python.
Last updated: 2023-10-02
When using the Element Collections library, is there a proper way to remove a dynamically created collection from memory?
CODESYS Forge
talk
(Thread)
When using the Element Collections library, is there a proper way to remove a dynamically created collection from memory?
Last updated: 2023-10-31
Post by pistola on Checking or changing objects dimensions using code.
CODESYS Forge
talk
(Post)
That works, thanks, I was trying to get a variable into the Position>Height and was struggling, then I was using absolute movement, never though to try relative movement.
Last updated: 2024-11-19
Post by thn-power on Opaque NodeId in the OPC UA server
CODESYS Forge
talk
(Post)
I'm wondering the same. Using the old symbol configurator opc ua server gave the node id using a string. Must be a way to specify this at build time?
Last updated: 2024-12-16
Post by caliberbishop on Having trouble using the Web Client SL library
CODESYS Forge
talk
(Post)
Edited: Thank you, after further inspection the library is unavailable in the example project for some reason, but using the correct Namespace in my project solved the problem.
Last updated: 2025-10-07
Is there a way to Connect Visualization to a web that the buttons can be used using a mobile phone?
CODESYS Forge
talk
(Thread)
Is there a way to Connect Visualization to a web that the buttons can be used using a mobile phone?
Last updated: 2021-04-22
getting compile errors C0035 and C046 for instances of FB when using redundancy, without redundancy => no errors
CODESYS Forge
talk
(Thread)
getting compile errors C0035 and C046 for instances of FB when using redundancy, without redundancy => no errors
Last updated: 2022-10-19
I am using wago 750-871 plc but in codesys software i can't find the target module if any have TSP for this module
CODESYS Forge
talk
(Thread)
I am using wago 750-871 plc but in codesys software i can't find the target module if any have TSP for this module