Post by rafa on MODBUS TCP SERVER DONT AUTO-STARTUP
CODESYS Forge
talk
(Post)
Dear all, I have a project where I have two ModbusTCP communication drivers in the application. It's working normally until a power outage or the installation panel is restarted. As soon as the PLC CPU is restarted, the Ethernet port is OK, but the TCP Server displays an "UNDEFINED" error. I can't reset the error using the diagnostic confirmation or the "mbserver.xConfirmError" bit. I noticed that the error only appears in the "mbserver.byModbusError" memory and the description is "UNDEFINED." The "mbserver.xError" memory doesn't flag an error. When using the warm restart function and then START CPU, the devices return to normal operation. The following demonstration images; The main question is: How can I make devices boot automatically?
Last updated: 2025-07-15
Post by beavel on Customizing FileOpenSave Dialog and Keypad Integration in Visualization
CODESYS Forge
talk
(Post)
Hi all, I'm looking to adjust the visualization of the FileOpenSave dialog. Is there a library or visualization file associated with this dialog that can be extracted, customized, and re-imported into the project — similar to how the user management dialogs can be handled? Alternatively, is there a supported way to replace or override the default dialog with a custom one? Also, is it possible to configure the FileOpenSave dialog to use a custom keypad for text input? The rest of the project uses a custom keypad due to readability concerns (the default one is too small), and this inconsistency is now quite noticeable. Any guidance or workarounds would be greatly appreciated. Thanks in advance! @thk @eschwellinger @sheberle
Last updated: 2025-09-08
Post by niloufar on Execution Order of Function Blocks
CODESYS Forge
talk
(Post)
Hi, Our program incorporates various function blocks and programs written in different languages such as St and SFC. They implement numerous actions and methods using different languages from their function blocks. My question is whether the execution order of function blocks is associated with the programming languages used. I understand that cycle time can be configured in the task configuration, but I'm curious if there is a specific sequence order of execution for function blocks written in different languages. For example, all function blocks in (ST) are executed first, followed by the execution of (SFC). Specifically, when the function is written in (ST) and the action is implemented in (SFC). I modified all function blocks in the main PLC program and configured a task configuration for the main program.
Last updated: 2023-12-13
Post by jmohre on External file with relative path
CODESYS Forge
talk
(Post)
I try to add a simple text file to my PLC application, so that is download everytime the application is downloaded to the target. What I did is to add an external file to the application and this works perfect as long as the external file location does not change. It looks like the external file path is stored absolute in project. But if different users work on the project they may have different locations where for their working directory. Is there an option to store the external file path relative e.g. to the project file? Or does s.o. know a different solution to add a text file to application in order to download automatically with the application? Thanks
Last updated: 2024-01-04
Post by idalu on Profinet PN_Controller Issue, Network Adapter
CODESYS Forge
talk
(Post)
i have a problem with Profinet on my project. I'm using Codesys RTE 3.5.19.50. When i download program to controller the ethernet is ok, PN_Controller is ok but every device i'm trying to connect is red with error "DCP no RealStationName". When i'm trying to Scan for Devices on PN_Controller there are no devices found. I have installed Codesys driver CmpEt1000Drv to my network adapter (i'm sure it is right intel pro 1000 model). I have noticed that when i installed codesys driver i'm no longer able to ping this network adapter (i can ping it when intel driver is installed). On my previous projects with runetimes i can ping it even with codesys driver installed. I have also tried to do downgrade of everything to version 3.5.19.20 and it not helped.
Last updated: 2024-01-17
Post by matt-s on HMI Pushbutton/Move Instruction
CODESYS Forge
talk
(Post)
I am having an issue where the manual start/stop push buttons on the HMI are supposed to take the pumps/blowers out of auto. The logic I have attached works for the pumps, but not the blower. From what I can tell it is the exact same logic, but it is not writing a 0 to the Auto PB variable. Attached is the logic, cross reference list to show nothing else is writing to it, and the HMI screen. Any help? Am I missing something? I am using a Groov Epic PR1, my software version is 3.5 SP19 Patch 5 32 Bit.
Last updated: 2024-01-25
Post by r-niedermayer on Issue with WebVisu on Raspberry PI
CODESYS Forge
talk
(Post)
Regarding to your application: When clicking in the web visualization, the boolean variable will be tapped for both buttons. The LED in the web visualization lights up as long as the variable is true The used variables should come from the GVL, ad/or thePLC_Prg. We see no difference or problem in both projects: You have created a visuelement Push button a a tapper, that is supposed to control the variable in this way as expected. This is also reflected (switching Bool from false to true) in the program code, as well as in the (GVL declared) variables. Wherever the misunderstanding comes from: no, this is not memory or license related. Our best guess: it is probably more of an applicative/conceptual implementation.
Last updated: 2024-04-11
Post by reinier-geers on License problem gateway
CODESYS Forge
talk
(Post)
Epis doesnt want Softmotion. I thought it was about the price. If it was possible it would be working already and i dont need an extra licence. Thats the problem of codesys. The software is running but hangs on its license. Epis made it posible to see the stick. I can see the license. Softmotion is there from 3.5.14.Xx Like is said And Motion control is alrady posible 15 year ago. And i only need a Sync of 2 drives. I want a good solution not a refund. Dont point to the manufacturer. The software is made by 3s not by epis .
Last updated: 2024-04-29
Post by esave on Softmotion Light Problem: The license is missing or invalid
CODESYS Forge
talk
(Post)
Hello everybody I want to controll a stepper driver from Leadshine (EM3E-556E). The EtherCat slave is CiA 402 compatible. Because of this I bought the Softmotion Light Package from Codesys and implemented it in my project. I rightclicked the EtherCat slave and added the Softmotion Light axis. But now the error message shows: "The license is missing or invalid. The PLC runs in demo mode." What have i done wrong? I use Codesys 3.5.17. Is it possible that the stepper driver is not compatible with the Softmotion license? Thanks for all your help
Last updated: 2024-05-02
Post by k2saki on CNC Open Source Project / Can I convert my project to text-files ?
CODESYS Forge
talk
(Post)
Hi. I published My CODESYS-CNC Project to GitHub and I set it Open Source Software. Here https://github.com/k-s-saki/RPi_CODESYS_CNC My CNC Project is binary file , using FBD for IPO , so I found it is a little bit hard to work with people on GitHub. (diff / merge ) My question is 1) Is it possible to convert my project ( only POUs is also fine ) into text file ? How? 2) Would it be better to rewrite all FBD/LD into ST and copy them manually to text files? Thanks.
Last updated: 2024-05-16
Post by remlab on WebClient result empty
CODESYS Forge
talk
(Post)
Hello, I try to read into a IPX800v4 (this is a PLC for domotic application) with a WebClient fonction I use as url http://192.168.0.250:50543/api/xdevices.json?key=XXX&Get=C XXX is replace by the correct key for sure The status code is 200, it should works correctly But the result is '{' that's my problem When I try the same url with a web browser the result is correct like { "product": "IPX800_V4", "status": "Success", "C1": 16, "C2": 2, "C3": 0, "C4": 0, "C5": 0, "C6": 0, "C7": 0, "C8": 0, "C9": 0, "C10": 0, "C11": 0, "C12": 0, "C13": 0, "C14": 0, "C15": 0, "C16": 0 } When i replace the url by a web site like google for exemple it works Can you help me please ?
Last updated: 2026-03-04
Post by mascara on JOG continues in WCS ( SMC_GroupJog2 )
CODESYS Forge
talk
(Post)
I'm using the SMC_GroupJog2 block from the SM3_Robotics library for manual movement of an AxisGroup in WCS coordinates. The observed behavior is: When pressing X+, the X-axis starts moving correctly. If I press Y+ during the movement, the block interrupts the current movement and starts a new movement in X and Y. If I release any button, all axes stop, even if another button is still pressed. Example: Pressing X+ → X moves Pressing X+ and Y+ → X stops momentarily and starts XY movement Releasing X+ while holding Y+ → all axes stop The expected behavior would be: to allow simultaneous continuous movement on multiple axes to not interrupt movement when another axis is added or removed. Is there a correct configuration of SMC_GroupJog2 to achieve this behavior, or is there another block more suitable for continuous manual jog in AxisGroup (WCS)?
Last updated: 2026-03-11
Post by mubeta on Some 'pathetic' errors in SoftMotion program
CODESYS Forge
talk
(Post)
Yes, this is the error the sometimes show up. What make me crazy is the fact that it happens randomly and not each times. I know very well where the problem is, in wich one program row it's located. For each actions of the state machine I have all events recorded with log on text file. it is not problematic for me to find the application point of the fault, but I need to understand why occasionally and for no apparent reason, switching the state machine and thus changing the motion FB, sends the axis into failure (but only occasionally). For example, one case that is often problematic is the execution of the Axis Halt instruction. When, after a MoveAbosulte instruction this returns the event as 'done' and indeed the axis is in standstill, the state machine first sets the move instruction to FALSE, and the next cycle sets the Halt request to TRUE. Some of the time everything works out fine. Occasionally, however, in this exchange, the axis goes into fault, also losing the OPERATIONAL state. Meanwhile, I would like to understand why the motion FB instances must still be called even after the Execute is set to FALSE, especially in view of the fact that the next instruction is programmed to abort the previous one, with BufferMode set to 'Aborting'. All these unnecessary FB calls are an unnecessary overhead on the CPU anyway. Is there any precise rule about when to cease calling the various instances? (It should precisely be the 'done' status that says this one has finished its work).
Last updated: 2024-07-18
Post by alexgooi on Codesys KNX implementation
CODESYS Forge
talk
(Post)
Dear forum, We are currently doing some research on the Codesys KNX implementation (https://store.codesys.com/en/codesys-knx-sl.html). We almost have it working but we are missing the last part. The setup: We have a Codesys virtual control container running on docker (4.17.0.0), the I/O is running over an Ethernet IP coupler (Weidmüller), and this is running fine. As far as I’m concerned this tells me that the ethernet device is working properly (the container has access to the outside world, including multicast). Underneath this ethernet adapter the KNX module is added (see picture). In the KNX device (Codesys) 2 input variables are added (see picture), and these are exported to ETS (ETS 5). In ETS A Codesys KNX device has been imported and the Codesys export was imported, afterwards the group addresses are attached to the variables (see picture). Afterwards this configuration is downloaded to the Codesys controller (Container) via ETS. ETS asks for the pressing of the programming button, when the virtual programming button is pressed the download starts and finishes without any errors. This tells me that ETS is communicating with the Codesys controller, and that the download process is ok (so far so good). Now the part where we are struggling with, somehow we need to convert the KNX TP to KNX IP. For this we have the following interface: Zenio KIPI SC (https://www.zennio.com/product/kipi-sc/) this is a KNX TP to IP interface. We have the following setup for this device (see picture) (an IP in the same subnet is used). We tried multiple combinations of IP addresses but the TP devices are simply not communicating to the Codesys container. Does anyone has any advice on what to try next. To make the question more explicit how can we link the TP bus to the Codesys device? Kind Regards Alex
Last updated: 2026-01-05
Post by thejesh on WebVisu: switch-frame destroys and rebuilds referenced visualization - is retention configurable?
CODESYS Forge
talk
(Post)
Hi, HTML5 Conrtrol elements on CODESYS V3.5 SP22 Patch 2, WebVisu only (no TargetVisu). The client is Chromium 147 in kiosk mode on a Raspberry Pi CM5 panel; the runtime is CODESYS Control Win V3 x64/CODESYS Control RTE V3 x64 on a separate IPC. I have measured that changing a Frame element's switch-frame variable destroys the currently referenced visualization and fully rebuilds it on return, including all embedded HTML5 controls. We would like to know whether this lifecycle is configurable. Measurement 1: Curently, our production page contains a good number of custom HTML5 controls and will only increase , each of which the WebVisu client instantiates as a separate about:srcdoc iframe. I counted live targets via the Chromium remote debugging endpoint (curl http://localhost:9222/json/list) before and after switching. Production displayed (index 0) 108 iframes Switched to a light page (index 1) 46 iframes Switched back to Production 108 iframes 62 controls are destroyed on leaving the page and re-instantiated on return. Observed latency was approximately 2.5 -5s away from the heavy page and approximately 4.0 -5 s back to it. This was measured with the panel otherwise idle: 2.8% system CPU, 97.1% idle, 2 h 56 min uptime, no remote-desktop session running, hardware acceleration confirmed active in chrome://gpu. I had previously measured the same behaviour under a much higher CPU load and have since resolved that load separately (VISU_TASK cycle period), so I am confident the rebuild is the frame lifecycle itself and not CPU starvation. Measurement 2 — frame offset instead of switch index I then displayed the same overlay page by a different mechanism. Instead of using a switch-frame index, I placed the page in a fixed Frame parked off-screen below the visible canvas, and drive its Y offset from an INT in Structured Text to move it into view. With this approach the overlay appears immediately, the production page underneath is never torn down and keeps updating, and no visualization is destroyed or rebuilt in either direction. The iframe count does not change at any point. This is the same visualization, containing the same HTML5 controls, as in Measurement 1 — the only difference is how it is brought on screen. So the rebuild appears to be a property of the switch-frame mechanism specifically, not of the page or its control count. Questions: Is the destroy-and-rebuild behavior on switch-frame the intended and documented lifecycle for WebVisu? Is there any setting, property or client option that causes a referenced visualization to remain instantiated when it is not the active index — the equivalent of keeping it mounted but not displayed? Does the runtime or client offer any form of caching or pre-instantiation for referenced visualizations, so that a return switch does not pay the full construction cost? Is the cost specific to HTML5 controls, or would the same rebuild occur with an equivalent number of native visualization elements? We ask because it would inform whether reducing our HTML5 control count is a viable solution. Is there a recommended pattern for showing a full-screen page over a live production screen without tearing the production screen down? My current workaround is to keep every page permanently instantiated and move it on and off screen by driving a frame offset variable, which avoids the rebuild entirely but means every page stays live and consumes client resources for the life of the session. This works, but I would prefer to use the supported mechanism if one exists. Any help on this is greatly appreciated. Thank you!
Last updated: 2026-08-07
Post by elektron785 on GPIO mit Codesys Virtual Control for Linux ARM64 SL
CODESYS Forge
talk
(Post)
Hallo zusammen, ich möchte an einem Entwicklungsboard auf dem der i.MX 8M Plus von NXP aufgesteckt ist die vier zur Verfügung gestellten GPIOs als Ausgänge verwenden. Ich habe mir dazu die Readme-Datei des GPIO-Beispiels von "C:\Program Files\CODESYS 3.5.20.40\CODESYS\CODESYS Control SL Extension Package\4.14.0.0\Examples\GPIO" angeschaut Die Übersicht der verfügbaren GPIOs sieht folgendermaßen aus - wobei ich das auf die reduziert habe, die für mich von Interesse sind: gpiochip0: GPIOs 0-31, parent: platform/30200000.gpio, 30200000.gpio: gpio-0 (SODIMM206 ) gpio-1 (SODIMM208 ) gpio-2 ( ) gpio-3 ( ) gpio-4 ( |sd-vsel ) out hi gpio-5 (SODIMM210 ) gpio-6 (SODIMM212 ) gpio-7 (SODIMM216 ) gpio-8 (SODIMM218 ) gpio-9 ( ) gpio-10 ( ) gpio-11 (SODIMM16 ) gpio-12 (SODIMM155 |regulator-usb1-vbus ) out lo gpio-13 (SODIMM157 ) gpio-14 (SODIMM185 |regulator-usb2-vbus ) out hi gpio-15 (SODIMM91 )** Füge ich nun das GPIO (1 Bit)-Gerät in meinem Codesys-Programm hinzu funktioniert der Bus solange bis ich die Richtung in den GPIO-Parametern von "not used" auf "Output" stelle (siehe Bild gpio_parameter). Dann funktioniert nach Download der Bus nicht mehr. Gibt es noch eine andere Möglichkeit das zu steuern oder muss ich noch Einstellungen tätigen? Für die Zeile mit dem echo (export/unexport) aus dem Beispiel fehlen mir trotz sudo die Zugriffsrechte. "The Kernel Linux has deprecated GPIO user space SysFS. However, the kernel config CONFIGGPIOSYSFS is still enabled on Toradex's BSP to support customers using it in their legacy applications. You can check the configuration by running zcat /proc/config.gz | grep CONFIGGPIOSYSFS. For GPIO access from userspace, the new char device API, also known as libgpiod, must be used." Dies steht in der Verwendung der GPIOs - eine Ausführung des zcat-Kommandos liefert ein =y zurück.
Last updated: 2025-03-17
Post by gunstr on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
I now tried to install 4.17.0.0 on a fully clean installations: A brand new RPi 4B Install latest Raspberry Pi OS Lite, Release date 13 May 2025, 64bit run sudo apt update && sudo apt full-upgrade When asked - Select to install the updated version of '/etc/initramfs-tools/initramfs.conf' Install CODESYS Control for Raspberry Pi SL. version 4.17.0.0 Log output: [INFORMATION] Connected successfully! [INFORMATION] Successfully connected to target (192.168.0.197) [WARNING] No supported container engine found on device. You have to install a supported container engine to use Virtual Control. Please contact the Administrator of the device. [WARNING] Error detecting container architecture [INFORMATION] Finished reading device information [ERROR] Error output: /var/lib/dpkg/info/codesyscontrol.postinst: 88: check_legacy_extensionapi_folder: not found [INFORMATION] Standard output: Selecting previously unselected package codesyscontrol. [INFORMATION] Standard output: (Reading database ... 76772 files and directories currently installed.) [INFORMATION] Standard output: Preparing to unpack .../codesyscontrol_raspberry_4.17.0.0_all.deb ... [INFORMATION] Standard output: Unpacking codesyscontrol (4.17.0.0) ... [INFORMATION] Standard output: Setting up codesyscontrol (4.17.0.0) ... [INFORMATION] Standard output: make config rw [INFORMATION] Standard output: set folder permissions [INFORMATION] Standard output: prepare permissions [INFORMATION] Standard output: check legacy extension api folder [INFORMATION] Standard output: create and install daemon [INFORMATION] Standard output: codesyscontrol started [WARNING] Unable to detect Raspberry Pi Architecture. Setting armv6l as default, you can change this through the settings panel. [INFORMATION] Standard output: codesyscontrol stopped [ERROR] Expected exit value of command failed: expected 0, received 1 [WARNING] Error setting the Raspberry Pi Architecture [ERROR] Error installing codesyscontrol If I read the log correctly the control is actually installed but cannot start. I'm running out of ideas how to proceeed now, any suggestions are welcome.
Last updated: 2025-09-03
Post by ryandmg on Web Client (HMI) Disconnects from Webvisu (Weidmuller u-OS)
CODESYS Forge
talk
(Post)
Thanks So Much for the reply! Were using the Weidmuller UV66-ADV-10-CAP-W The HMI is pointed to the URL which is assigned through u-OS. Basically when you log into the controller's webserver via browser you can view the installed apps. One of which is the Codesys runtime. When you click on that it takes you to the visualization. That corresponding url is what the HMI is looking for. I apologize I don't have that on hand as I'm in the office right now. I don't think I tried connecting using the port you mentioned and https in lieu of the u_OS URL. I can certainly try. Out of the box the u-OS is set for HTTP. Since we're isolated I havent changed that yet. When this has happened while logged on via chrome on my laptop, simply refreshing brings the visualization right back. In the case of the HMI in kiosk mode, we power cycle the HMI to force a reconnect, log back in u-OS and the visualization is back.
Last updated: 2023-09-06
Post by pernockham on Persistence Manager: Config File not found?
CODESYS Forge
talk
(Post)
Back in november I paused this, but wanted to reattempt using the persistent manager, the behavior is still the same. Most "login attempts" s are stopped with the message "One or more errors occurred" but I have no idea what that error might be. The only clue is this message is presented while the lower left status box says "Generating code...: relocation pou". For clarification. Build/Generate code is successful, no errors. Error appears when I try to download/login (physical or simulation) to a device. I did manage to login (in simulation mode) at one point, but then the error message "PersistenceChannel: Config file not found!". And no persistence files were created. I have done device-tree/reset-orgin also clean/clean all etc. Removed/re-inserted persistance manager. Behaviour is just the same. Removing Persistence Manage and everything is working OK. Is there possibly more info somewhere about the "One or more errors occured"-message?
Last updated: 2025-03-20
Post by r-c-r on SM3RaspiStepper 0.0.0.6 issue
CODESYS Forge
talk
(Post)
Ok, so i made some tests in the meantime and i have some conclusions. It apears that the enable bit is activated only when a motion function is executed. I implemented a very simple program with MC_Power and MC_Jog. If i enable everything on MC_Power, the enable GPIO pin stays off. However, as soon as the MC_Jog function is used the enable GPIO pin turns ON and remains ON. In version 0.0.0.4 this is not happening. The GPIO enable pin turns on or off when the MC_Power is enabled or disabled. From this behaviour i understand that in version 0.0.0.6 the GPIO enable bit is activated together with pulse and dir pins when motion starts. When motion stops, enable bit remains with the last state (on in this case) and you cannot turn it off for example. For me this bit is useful because i can turn on and off the stepper drive with MC_Power function. Now i can turn it on, but never off.
Last updated: 2025-04-04
Post by gseidel on AXIS_REF_SM3 Error Codes?
CODESYS Forge
talk
(Post)
Hi SLUCodesys, dwErrorId is a drive specific error number. The drive documentation should be consulted to interpret it. (Note that you should use MC_ReadAxisError to read this error, see https://content.helpme-codesys.com/en/libs/SM3_Basic/Current/SM3_Basic/POUs/Diagnostics/MC_ReadAxisError.html. Accessing the internal variable will result in outdated values if the acis error is not mapped by PDO and is not recommended in general.) uiDriveInterfaceError holds errors of the SoftMotion driver for the drive. It is also an internal variable, not intended for direct access. It is intended for logging, the PLC log will contain the drive interface error, consisting of this number and an error text. My recommendation for handling axis errors in the CODESYS application: 1) Use MC_ReadStatus on the axis to find out whether it is in state Errorstop 2) If in Errorstop, there are two possibilities: an error reported by the drive (MC_ReadAxisError) or an error of the SoftMotion function blocks (output MC_ReadStatus.FBErrorOccured). 3) If there is no drive error, you can use SMC_ReadFBError https://content.helpme-codesys.com/en/libs/SM3_Basic/Current/SM3_Basic/POUs/Diagnostics/FBError/SMC_ReadFBError.html Best regards, Georg
Last updated: 2025-09-24
Post by farren on How to stay in a method until something is finished.
CODESYS Forge
talk
(Post)
I know I'm thinking about this wrong -- too many decades of procedural and event-driven programming and only a few months of PLC ST programming...... I've created a visualization with a button that when pushed calls a method. I want the method to take a pressure reading, wait one minute and then take another pressure reading. I'm looking for leaks. I'm using TON for the delay. It seems like what is happening is that the method gets called once and it takes the first reading and starts the TON. But then execution continues, leaves that method call, and the second reading never happens. I can force the method to keep running until the whole thing is done with a While loop, but I understand that is considered BAD in PLC programming. If it push the button again to call the method again, it picks up where it left off and if the timer is complete then it runs the remaining code. How do I keep that method running until it is complete with just one call without using a while loop that ties up the PLC for a minute? Thanks! -Farren
Last updated: 2025-10-31
Post by fajean on Issue with library updates
CODESYS Forge
talk
(Post)
We make heavy use of internally developed libraries, which are often nested on multiple levels. I routinely work simultaneously on several libraries along with a project that use them. I make changes to a library and immediately perform a download (online or otherwise) in the project. For the longest time, we had zero issue with this. But starting a good while back, with 3.5 SP19 I think, CODESYS started not noticing library updates in other instances most of the time. When the update is missed, the project sees no need to update the code, and any download ignores the new code. A "Clean all" does not solve the issue. But if I close and then re-open the project, then the new version is noticed and the download works. The other solution is saving the library to the registry multiple times (say, 20-30 times, less if lucky), and then at some point the project notices the changed library. I am now on SP21, and it is still not fixed. This is driving me mad, any tasks probably takes me double the time or more due to this problem. My colleague has the same problem on a separate computer. Is this a known issue? Is there a setting somewhere that changes how updates are checked? Thanks for any help!
Last updated: 2026-02-13
Post by tk096 on Some 'pathetic' errors in SoftMotion program
CODESYS Forge
talk
(Post)
Meanwhile, I would like to understand why the motion FB instances must still be called even after the Execute is set to FALSE, especially in view of the fact that the next instruction is programmed to abort the previous one, with BufferMode set to 'Aborting'. All these unnecessary FB calls are an unnecessary overhead on the CPU anyway. Is there any precise rule about when to cease calling the various instances? (It should precisely be the 'done' status that says this one has finished its work). In general: - Motion function blocks have to be called until they report 'Done', 'Error', 'CommandAborted' or a subsequent motion FB with BufferMode=Aborting is started in the current cycle. - Setting the Execute input to FALSE will not abort any ongoing motion of the motion function block. For example, one case that is often problematic is the execution of the Axis Halt instruction. When, after a MoveAbosulte instruction this returns the event as 'done' and indeed the axis is in standstill, the state machine first sets the move instruction to FALSE, and the next cycle sets the Halt request to TRUE. Some of the time everything works out fine. Occasionally, however, in this exchange, the axis goes into fault, also losing the OPERATIONAL state. I think the error SMC_FB_WASNT_CALLED_DURING_MOTION is only a follow-up (and misleading) error that results from the axis not being in operational state anymore (bus problems). Is there an error 'regulator or start not set' in the device log before the error 'motion generating FB wasn't called for at least one cycle'? Which error does the respective function block (Halt.ErrorId) report?
Last updated: 2024-07-22
Post by gerdkoch on Dynamic I/Os Mapping
CODESYS Forge
talk
(Post)
Hi, I assume that you have a Pfc200 G2 or something and work with the original WAGO runtime. Then I would recommend the WagoSysDynamicIoMapping. Here in the example projects there is a PDF file for the library: https://downloadcenter.wago.com/learning-material/details/ll0w3pmdunzvem83g1 There is a global functional component in a GVL of the library. I think it's called DynKbusIoManager or something. The active terminals are registered there. Then there are filter Fb's for e.g. the first clamp with a specific article number. Everything is in the PDF.
Last updated: 2023-08-18
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.