Post by jdjennings1962 on Trouble accessing Math functions in OSCAT library
CODESYS Forge
talk
(Post)
Hi all, I am trying to utilize the ARRAY_SDV standard deviation function, part of the Math group in the OSCAT library downloaded from the CODESYS store. My Codesys version is 3.5.19.10. When I add the OSCAT to my Library, it shows a subset of the library (Standard) as fully installed and signed (see pic). However, the Math functions are not in this Standard group. The Math functions I need can be viewed as source code in the full OSCAT_BASIC, though this the symbol next to this library suggests it is source only and not fully installed. When I try to declare an instance of the ARRAY_SDV function in a program, it is not known. I have tried reinstalling and Building . . . Any help would be greatly appreciated. Jeff
Last updated: 2024-01-06
Post by toby on Ethercat Servo Setup
CODESYS Forge
talk
(Post)
Hi everyone, so a little update to this, I've come back to this project in the new year, and got it working. Yeah!, However, now with the new licensing setup, I need a new SoftMotion license, but it doesn't seem to be compatible with the previous Raspberry Pi SL license. Has anyone had any luck with Raspberry Pi and SoftMotion_Lite? Specifically the licensing of such? My customers new installation needs to be rebooted every 30min which is causing headaches! Another option is to not use the SoftMotion function blocks, and control the EtherCat amplifier directly, but I'm not sure how to do so. Does anyone have a specific example project of how to control a servo without the use of the SoftMotion function blocks? Thanks everyone for any assistance rendered. It's very much appreciated! Toby
Last updated: 2024-01-10
Post by dkugler on Toggling Visualizations using HMI Physical Buttons
CODESYS Forge
talk
(Post)
the magic option is named "Use CurrentVisu variable" activate this option in the Visualization Manager an have a look: https://help.codesys.com/webapp/_visu_obj_manager;product=core_visualization;version=3.5.14.0 if your button is pressed, "feed" the string varable VisuElems.CurrentVisu := 'visu1'; with the correct name of the depending visu. alternative: place a frame element at a empty main visu, konfigure all visus to be shown by this frame. With setting the switching variable of the frame to the index value of the depending visu, it will switch to it. Advantage: the visu names are not hardcoded as string in the ladder lodgic. Good luck! Hint: If you have multiple VisuClients(Target, WebVisu,...) all will show the same visu. Independent switching is much more difficult, but there is a example from codesys.
Last updated: 2024-02-13
Post by nmcc on How to address visualization change with button press...
CODESYS Forge
talk
(Post)
Hello all, I am extremely new to Codesys and to programming with these languages in general. I have an HMI panel with 8 physical buttons to the right side of it. I am trying to have these set to change the visualization to a specific screen which I have designed 8 of. I currently have "use CurrentVisu" enabled in the visualization manager. I also have input blocks with all of the buttons being directed to output blocks which I want to have as the switcher for the visualization. Picture is attached for what I have currently. This could be the wrong approach to this issue. Any help is much appreciated.
Last updated: 2024-02-13
Post by arundara on OPC UA Server Stops after 5 consecutive disconnections of ethernet port
CODESYS Forge
talk
(Post)
Hello Every one, During testing of OPC UA communication between UA Expert software and the CODESYS SoftPLC on a Linux environment, an observation was made. When the Ethernet cable was disconnected and reconnected with 2-minute intervals, on the 5th attempt, the OPC UA connection failed to establish in UA Expert software. At this juncture, restarting the CODESYS SoftPLC enabled the reestablishment of OPC UA communication. The same result was obtained when testing on a Raspberry Pi SoftPLC. What is the reason behind this phenomenon? and whether there are settings to stop this behavior? Please help. Thanks & Regards.
Last updated: 2024-02-13
Post by nmcc on How to address visualization change with button press...
CODESYS Forge
talk
(Post)
Hello all, I am extremely new to Codesys and to programming with these languages in general. I have an HMI panel with 8 physical buttons to the right side of it. I am trying to have these set to change the visualization to a specific screen which I have designed 8 of. I currently have "use CurrentVisu" enabled in the visualization manager. I also have input blocks with all of the buttons being directed to output blocks which I want to have as the switcher for the visualization. Picture is attached for what I have currently. This could be the wrong approach to this issue. Any help is much appreciated.
Last updated: 2024-02-13
Post by alexgooi on Function Blocks and arrays of function blocks
CODESYS Forge
talk
(Post)
Hi Jack, I think you have to look at a FB in a different way. A Function block (Class) can contain its own data. In other words don't define loose data in your GVL, but define a instance of a FB (Object) in your GVL: Example: Function_Block Basic_Class VAR_INPUT Open_Command: BOOL; END_VAR VAR_OUTPUT Opened: BOOL; END_VAR if Open_Command then Opened := TRUE; ELSE Opened := FALSE; END_IF Global Variables Objects: ARRAY[1..100] OF Basic_Class; //Here you ar defining you objects END_VAR In your code you can directly acces the data and couple it to the IO: GVL.Objects[1].Open_Command := %IX0.0; %QX0.0 := GVL.Objects[1].Opened; //To call the code itself use: GVL.Objects[1](); If you want to take this a step further you are also able to add methods and properties to the FB/Class end thereby creating a OOIP program
Last updated: 2024-02-15
Post by phoward131 on Text List Fallback Value
CODESYS Forge
talk
(Post)
I am relatively new to Codesys and I'm trying to develop an HMI that displays what mode a particular device is in based on an integer value. I am currently using dynamic texts with a text list which works fine but I am looking for a way to display a particular string (ie 'Unknown') when the index doesn't match any of of the indices in the text list. I can enter 'Unknown' in the text property of the text field element which works as expected but it displays the single quotes on the visualization. How can I escape these quotes to simply display the word Unknown? Thanks!
Last updated: 2024-03-22
Post by jrsantab on Remote connection to ifm PLC & HMI
CODESYS Forge
talk
(Post)
Hello, We are trying to access remotely a PLC (ifm 711S) and a HMI (ifm CR1077). Both are connected to a Teltonika RUT200 router. We establish the connection with OpenVPN Connect and can ping both controllers. We have a laptop that, most of the time, will allow Codesys connection to the controllers, but we have several other computers that are unable to connect, although all of them can ping successfully. We cannot find any difference in the configuration or software installed from one PC to another. If we connect to the router by WIFI, instead of VPN, all the computers work fine. We know that scanning the network will not work over a remote connection, so we input the controller IP directly. Has anyone had a simlar problem and can offer any hint on what to check to meke the connection run?
Last updated: 2024-04-11
Post by jrsantab on Remote connection to ifm PLC & HMI
CODESYS Forge
talk
(Post)
Hello, We are trying to access remotely a PLC (ifm 711S) and a HMI (ifm CR1077). Both are connected to a Teltonika RUT200 router. We establish the connection with OpenVPN Connect and can ping both controllers. We have a laptop that, most of the time, will allow Codesys connection to the controllers, but we have several other computers that are unable to connect, although all of them can ping successfully. We cannot find any difference in the configuration or software installed from one PC to another. If we connect to the router by WIFI, instead of VPN, all the computers work fine. We know that scanning the network will not work over a remote connection, so we input the controller IP directly. Has anyone had a similar problem and can offer any hint on what to check to make the connection run?
Last updated: 2024-04-11
Post by mbmik on IoDrvModbusTCP_Diag not defined when using MODBUS
CODESYS Forge
talk
(Post)
Hi Im trying to setup a Weidmüller WL2000 to run with MODBUS, to get some data from a server. Codesys V3.5 SP20. The issue is, that whenever i attach an ethernet port and add MODBUS Master und also a Slave, codesys will compile the project, but there always seem to be some remaining errors, which or only visible, when setting the messages window to "Pre-Compiled". I tried a lot of stuff to get rid of these errors, but cant find to seem the reason. New installation of codesys, cleaned project, setup completely empty new project, manually adding libs. Nothing helps. Any help is apreciated. Maybe we are doing something wrong.. Example Project is available, if somebodey wants to take a look. Greetings and thanks alot
Last updated: 2024-04-15
Post by bjarne-pagaard on Codesys v3.5 Sint to byte
CODESYS Forge
talk
(Post)
Hi A SINT is a short (signed) integer. It is already only 1 byte - so you should have no problem casting it to a byte like so: bMyByte := TO_BYTE(sintMyShortInt); If you have a regular INT you want to put in 2 bytes - there are a lot of ways you can do this. A Union is certainly one of them. You could have a union with 2 memebers: An array of 2 bytes as one member, and an integer value as another member. Another way would be to look at MEMCPY to put the value into your CAN-message. .. or create a function to take your input value as input, and giving you 2 individual bytes as output. This could be handy if you need to change the byte-order. Integer data types: https://help.codesys.com/webapp/_cds_datatype_integer;product=codesys;version=3.5.17.0 -Bjarne
Last updated: 2024-04-24
Post by fajean on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
4.11 appears to solve the problem. Thanks for your help. I had first installed the 64-bit version of RPiOS, but looking at various posts and the product's page on the store which only lists 32-bit compatibility, I downgraded to the 32-bit version. I did this before trying 4.11, and it did not solve the problem. Thus my working system is 32-bit, and I am wondering if I can go back to 64-bit or not. An 64-bit OS is not listed as compatible on the store's web page, but when installing there actually is a 64-bit version listed (automatically chosen when installing on 64-bit, but otherwise greyed out). Is 64-bit supported and the website is out-of-date, or is that some kind of work-in-progress?
Last updated: 2024-06-13
Post by kazuhiro on Problems using MySql Library and SysProcessExecuteCommand2 together
CODESYS Forge
talk
(Post)
I use fbMsSQL_compact(FUN) of the MySQL Library to write data to the database. There is no problem when writing data using only fbMsSQL_compact(FUN). However, when I try to write data obtained using SysProcessExecuteCommand2 to the database using fbMsSQL_compact(FUN), an error message "Dest server on ip address:xxx.xxx.xxx.xxx and port:1433 is unreachable" appears and writing is not possible. From what I have researched, it seems that writing is not completed in one cycle of fbMsSQL_compact(FUN), and when SysProcessExecuteCommand2 is executed first in the second cycle, the work done in one cycle of fbMsSQL_compact(FUN) is reset. Could you please give me some advice?
Last updated: 2024-06-18
Post by kazuhiro on Problems using MySql Library and SysProcessExecuteCommand2 together
CODESYS Forge
talk
(Post)
I use fbMsSQL_compact(FUN) of the MySQL Library to write data to the database. There is no problem when writing data using only fbMsSQL_compact(FUN). However, when I try to write data obtained using SysProcessExecuteCommand2 to the database using fbMsSQL_compact(FUN), an error message "Dest server on ip address:xxx.xxx.xxx.xxx and port:1433 is unreachable" appears and writing is not possible. From what I have researched, it seems that writing is not completed in one cycle of fbMsSQL_compact(FUN), and when SysProcessExecuteCommand2 is executed first in the second cycle, the work done in one cycle of fbMsSQL_compact(FUN) is reset. Could you please give me some advice?
Last updated: 2024-06-18
Post by msirotkin on EtherCAT status errors
CODESYS Forge
talk
(Post)
Hello, I'm trying to understand the reason for the many errors on the EtherCAT master status page. If we set the cycletime to 1ms we see a lot of rxerrors and lostframes, but the send and recive times are quite good (see attachement). And the status of the EtherCAT bus is good (no other errors, all is green, slave has no errors) But when we set 2ms cycletime the lostframe errors are gone, but periodically increses rxerror counter (see attachement). The questions is, what do these errors actually mean and what we can do to get gid of them? Linux RT, imx8, Codesys runtime for ARM 3.5.21.10, Ethercat 4.10 Thanks
Last updated: 2025-11-25
Post by artem1223 on Synaxis of library declarations in the ST
CODESYS Forge
talk
(Post)
Codesys 3.5 17.30, plc - crevis GN-9373. I need to use RTC of pls for write in registers (need to check difference of writen 100 and 200 registers). For this i try to use SysTimeRtc (SysTimeRtc.SysTimeRtcGet) but its not working. After it i tryed to use SysTimeGetMs and something like this but still not working. Library? Mb but check project, SysTime with SysTimeRtc already, all what i know - already is here. Its my first try to learn ST (early used fbd and ladder, yeah), pls help with it. Mb problem with a syntaxis, but im not sure.
Last updated: 2025-11-26
Post by egau on Importing a library overrides parameters of a referenced library
CODESYS Forge
talk
(Post)
Hi, In my CODESYS project (ABC.project), I’m using the MQTT library. I’ve also created a separate library (DEF.library) which itself references the MQTT library. In ABC.project, I’ve customized some MQTT parameters—for example, setting g_udiMaxPublishersAndSubscribers to 100 instead of the default value of 20. However, when I import DEF.library into ABC.project, the MQTT parameters get reset to their default values. I assume this happens because DEF.library still uses the default MQTT configuration, which then overrides my project settings. A straightforward workaround would be to manually align the parameter values in DEF.library, but that doesn’t feel like the right approach. Is there a better or recommended way to handle this situation? I'm using SP18 Patch3. Any insights would be greatly appreciated. Thanks in advance!
Last updated: 2026-05-04
Post by baotthitawat on SCADA Systems Are Becoming Easier to Integrate With Modern Applications
CODESYS Forge
talk
(Post)
One thing I’ve been seeing recently is that more industrial systems are starting to expose realtime SCADA data through APIs instead of keeping everything isolated inside the local monitoring software. This makes integration much easier for cloud platforms, mobile dashboards, AI analytics, and enterprise applications that need realtime industrial data. Instead of exporting reports manually or building complicated middleware, APIs allow external systems to access SCADA data directly in realtime. I think this becomes especially useful for applications like wastewater treatment monitoring, where operators need better visibility into alarms, equipment status, and operational conditions across different locations. Feels like modern SCADA is slowly evolving from a standalone monitoring platform into part of a larger connected industrial ecosystem.
Last updated: 2026-05-28
Post by baotthitawat on SCADA Systems Are Becoming Easier to Integrate With Modern Applications
CODESYS Forge
talk
(Post)
One thing I’ve been seeing recently is that more industrial systems are starting to expose realtime SCADA data through APIs instead of keeping everything isolated inside the local monitoring software. This makes integration much easier for cloud platforms, mobile dashboards, AI analytics, and enterprise applications that need realtime industrial data. Instead of exporting reports manually or building complicated middleware, APIs allow external systems to access SCADA data directly in realtime. I think this becomes especially useful for applications like wastewater treatment monitoring, where operators need better visibility into alarms, equipment status, and operational conditions across different locations. Feels like modern SCADA is slowly evolving from a standalone monitoring platform into part of a larger connected industrial ecosystem.
Last updated: 2026-05-28
Post by baotthitawat on SCADA Systems Are Becoming Easier to Integrate With Modern Applications
CODESYS Forge
talk
(Post)
One thing I’ve been seeing recently is that more industrial systems are starting to expose realtime SCADA data through APIs instead of keeping everything isolated inside the local monitoring software. This makes integration much easier for cloud platforms, mobile dashboards, AI analytics, and enterprise applications that need realtime industrial data. Instead of exporting reports manually or building complicated middleware, APIs allow external systems to access SCADA data directly in realtime. I think this becomes especially useful for applications like wastewater treatment monitoring, where operators need better visibility into alarms, equipment status, and operational conditions across different locations. Feels like modern SCADA is slowly evolving from a standalone monitoring platform into part of a larger connected industrial ecosystem.
Last updated: 2026-05-28
Post by konstantin on CAM Motion Recover after STO
CODESYS Forge
talk
(Post)
Hello, one of the projects I work on is about a racetrack collator with two independent belts on it - two different servo motors. Both motors share the same mechanical frame and there is a train on a belt that collects items from the input conveyor. The way the motion is performed is the following - there is a virutal master axis and both real axis are synchronised with different cam motion profiles. The problem is when an STO is triggered on any of the slave axis, the synchronization process starts from position 0 of the slaves. How can I force the slaves to retain their current position until the master passes their position? Then the slaves should catch up with the master according to the profile, the slaves should not start synchronization from 0 position. Best Regards Konstantin Kolev
Last updated: 2026-02-12
Post by rik123456 on Alarmmanagement – Dynamic Alarm List
CODESYS Forge
talk
(Post)
Hi, I had a question about alarm management in the CODESYS visualization. I am currently investigating to what extent the alarm visualization can be built dynamically. In my program, I have developed a motor block that is used for multiple motors. When the emergency stop of one or more motors is activated, the corresponding motors are displayed in the alarm list (see image). This works quite well. I achieved this by linking variables to a latch, after which a piece of code displays the motors that are in emergency stop. My question is: do I need to create a separate latch for each motor or can I use a single latch to display multiple alarms of a motor underneath each other? This would then look like this: Time…: M1 Emergency Stop Active Time…: M4 Emergency Stop Active
Last updated: 2026-04-20
Post by timvh on library inside library
CODESYS Forge
talk
(Post)
1) it should be possible to access the type SysTime in the project as A_Lib.SysTime. 2) you could add the SysTimeCore library to the library manager of your library (POU Pool). This might seem as a double library, but because of the placeholder resolution only one will be used. Then, in your library manager of your library, select the SysTimeCore library, right-click, select "Properties" and enable the option "Publish all IEC symbols ...." For more information about library development, you could follow our advanced training course in Ridderkerk. The next is scheduled for 24 and 25 June 2026 https://www.extendsmartcoding.nl/codesys-training/
Last updated: 2026-04-25
Post by kurt9 on ReadWriteEEprom FB question
CODESYS Forge
talk
(Post)
I want to programmatically write the alias address to a new EtherCAT slave when I plug it into my IPC EtherCAT network. I am looking at the ReadWriteEEprom FB and see that one of the elements is "pbyData". which is the pointer to byte that is usually set to 2048 bytes. Since I am setting the alias address to the EEprom only (EEprom address 16#0012), I would assume that what I am writing is 2 bytes only. Does the pbyData have to be specified as ADR(myArray) where "myArray" is the 2 bytes of the alias address? How is the best way to set this element of the function block? Thanks in advance
Last updated: 2026-05-18