Post by timvh on Sysfile inuts
CODESYS Forge
talk
(Post)
To prevent ambiguous use of this enumeration value. Let's say another ENUM is available in your project or in another library which has an enumeration value AM_WRITE, then it is not clear which AM_WRITE you want to assign. By this qualified access to the SysFile.AM_WRITE, it is completely clear for the compiler.
Last updated: 2024-01-14
Post by smartcoco on Add visual background FB blocks.
CODESYS Forge
talk
(Post)
Can you add a background FB block to the visualization page, and loop through this FB block when the page is in display mode. This FB block requires two more functions, one for executing when the page is displayed and the other for executing when the page is closed.
Last updated: 2024-01-16
Post by scarter on Import/Export PLCOpen xml Task Configuration
CODESYS Forge
talk
(Post)
I'm Having the same issue. If I highlight PLC Logic and import it erases everything else and replaces the Task config. If I highlight the Application I get the same result. Simple manual fix is click and drag the task config onto the origional Application, and delete the second one. Easy fix but not the expected result of importing task config.
Last updated: 2024-01-17
Post by aniket-b on How to protect library project?
CODESYS Forge
talk
(Post)
I have library projects which has few function blocks. I have assigned security to each FB. I want to protect them and user can only be able to use it without viewing the code inside. What kind of file I should send to user? Is it compiled library file?
Last updated: 2024-01-22
Post by masmith1553 on SDO generation
CODESYS Forge
talk
(Post)
If you add any device to the CANOpen Manager it will send messages to verify the device is on the network. Do you have the Enable expert settings check box checked in the General tab? have you added any SDOs in the SDOs tab? I avoid using the CANOpen Manager and just use the CAN_Tx and CAN_Rx blocks from the library.
Last updated: 2024-01-25
Post by eschwellinger on New Ladder Diagram conversion does not work due to missing features
CODESYS Forge
talk
(Post)
The "remove unused" parameters have been added to 1.0 version as well as the "manual" removal of pins... also allowed "empty" inputs for blocks is in and the compile error described there should no longer occurs. Drag drop of variables is not yet implemented and I don't think the double-click feature yet either.
Last updated: 2024-01-29
Post by thomas-moba on "sudo"-Befehle über die Funktion "SysProcessExecuteCommand2"
CODESYS Forge
talk
(Post)
Wir haben jetzt so ziemlich alles probiert. Ohne sudo mit sudo, den Aufruf in ein Script gepackt (.sh und .py) und sogar ein eigenes kleines Linux-Programm geschrieben, weil wir vermuteten das der sudo-Befehl nicht im Klartext ausgeführt werden darf. Es funktioniert einfach nicht. Daher dir Frage: muss die codesyscontrol als root ausgeführt werden? Momentan wird sie als user ausgeführt.
Last updated: 2024-02-02
Post by nano on Modbus TCP/IP slave communication errow
CODESYS Forge
talk
(Post)
please tell us the exact error message from diagnostic. U can view it at devicetree in the node-element diagnostic from modbus-configuration. u also can activate the function auto-reconnect in master and increase a little bit the timeout and the repetition to male thw communication a little bit more robust
Last updated: 2024-02-04
Post by nima-khajehali on Data Transferring between 2 PLCs in a same PC
CODESYS Forge
talk
(Post)
Hi Guys, I want to simulate the data exchange between 2 soft PLCs on the same PC. We are trying to simulate the process and we could not see the desired result. What should I do to pass all data between these 2 PLC's correctly ? Please see attached
Last updated: 2024-02-05
Post by davidbo on Is it possible in the log to see previous shutdown
CODESYS Forge
talk
(Post)
If my application does some kind of violation which makes it cast an exception it will trigger my real watchdog which results in a reboot. Unfortunately the log it seems only shows the boot sequence. Is it possible to see what happen before reboot?
Last updated: 2024-02-08
Post by ferrim on IEC 61499
CODESYS Forge
talk
(Post)
Hello otdeveloper, I am very interested in this topic. I have been dedicated to IEC 61499 for some time and I would like to understand if the time has come to adopt it in the real world of automation or if it will continue to fill up research papers only.
Last updated: 2024-02-09
Post by kleeswi on Lizenz Reinstallieren
CODESYS Forge
talk
(Post)
Seit dem Update auf die Version V3.5 SP19 Patch 5 von der Version V3.5 SP17 haben wir das folgende Problem. Wir möchten von einem Gerät die Lizenz speichern. Damit wir nach einem neuen Raspberry Pi image die gleiche Lizenz für dieses Gerät brauchen können. Die Lizenz ist Geräte spezifisch so viel ich weiss. Bei unseren Geräten bei den Kunden hat es nicht immer eine Internetverbindung.
Last updated: 2024-02-19
Post by reinier-geers on SysFileOpen does not work after update to V3.5 SP19 Patch 5
CODESYS Forge
talk
(Post)
At 19.1 the hFile_test should be RTS_IEC_HANDLE and always open-write - close in one cycle udi_handle: RTS_IEC_HANDLE; //handle-number. Is created by SysFileOpen udi_handle:=SysFileOpen(sFileName,Sysfile.AM_WRITE_PLUS, ADR(udi_ErrorCode)); udi_RetValWrite:=SysFileWrite(udi_handle, pRemBuffer, szRemBufSize, ADR(udi_ErrorCode)); //closing file IF udi_RetValWrite < szRemBufSize THEN ui_Error:=cWriteError; END_IF//error writing data udi_ErrorCode_Close:=SysFileClose(udi_handle);
Last updated: 2024-02-19
Post by kleeswi on SysFileOpen does not work after update to V3.5 SP19 Patch 5
CODESYS Forge
talk
(Post)
Finally this solved my issue: https://forge.codesys.com/forge/talk/Engineering/thread/3da9ded84e/, and the official documentation https://faq.codesys.com/display/CDSFAQ/SysFile%2C+Persistence+Manager%2C+Datalog+Manager . Add the media folder to the PlaceholderFilePath. Like this: PlaceholderFilePath.2=/media/pi, $usb$ PlaceholderFilePath.2.View=1 PlaceholderFilePath.2.Volatile=1
Last updated: 2024-02-19
Post by alexgooi on Init Array input on a method
CODESYS Forge
talk
(Post)
Dear Forum, I would like to initialize an array input on a method. When I do this, I get the following error: "The type of ARRAY [1..2] OF BOOL cannot have a default value in this context." I attached a picture for more clarity. Is this simply not possible or is there a different way of tackling this problem? Thank you in advance
Last updated: 2024-02-26
Post by aarondw10 on Use element properties
CODESYS Forge
talk
(Post)
Assume I have a rectangle named rec1 from which I want to use the coordinates of the upper left corner. Is there a way to links these X and Y values from the properties to an integer defined in the main program? Note that I just want to use them and not change any of these coordinates in the program.
Last updated: 2024-02-29
Post by smartcoco on Dynamic object release issues
CODESYS Forge
talk
(Post)
Dear, When I use "__NEW" to dynamically create the object "Object_1", and assign this object "Object_1" to another object "Object_2". At this point, I use "DELETE" to release the object from "Object_2". At this time, I cannot judge whether the object has been released normally through "Object_1" (in fact, the object has been released theoretically). Thanks for you help.
Last updated: 2024-03-01
Post by macros8 on Viewing PDF in WebBrowser Visual Element
CODESYS Forge
talk
(Post)
My experience is that opening pdf file is very dependent on which browser is used. I have tried a couple of them and only Mozilla Firefox has opened file correctly in same screen. All other browsers face some issues. Therefor I had to flip my pdf to txt which has not been nice solution.
Last updated: 2024-03-01
Post by timvh on Limiting Memory Access of an Array to Within its Bounds
CODESYS Forge
talk
(Post)
Add the object "POU for Implicit Checks" to your application, then select "Bounds check". This will create a function which is automatically called each time an array is write accessed. In the function you can handle "out of bounds" situations. By default it will be limited to its lower or upper bound.
Last updated: 2024-03-06
Post by reinier-geers on Swap Output in frame
CODESYS Forge
talk
(Post)
How can i swap an output in a frame ? Ive got a frame of a mixer. use this twise. I want to turn these on and of. i can Get in the frame as dwAdr_Mixer : DWORD; . as Var_IN_OUT. Then Adress as Adr(Output ) But in the frame i cant swap dwAdr_Mixer^ :-= not dwAdr_Mixer^ ;
Last updated: 2024-03-11
Post by fless on How to change bHiresMode
CODESYS Forge
talk
(Post)
you need to set the increments to 10 (the screenshot shows 10000 hex = 65536). all the turn settings to 1. and the application units to 366. But usually you use the resolver resolution per motor turn. Insert the gear ratios (1:1 for no gear) and the last field you put the circumference of your drive wheel.
Last updated: 2024-03-12
Post by manuknecht on High Cycle Times for SoftMotion_PlanningTask when using AxisGroup
CODESYS Forge
talk
(Post)
Hi, we did install the real-time kernel patch on the RPI and also performed the additional optimizations including isolating the cores. Changing the configuration of the planning task e.g. running it on a separate core, changing the cycle times and mode from cyclic to freewheeling did not show any improvements.
Last updated: 2024-03-14
Post by bjarne-pagaard on Multiple WebVisu
CODESYS Forge
talk
(Post)
You can use the switch frame variable, but there should be a variable for each active visu user. You can put the switch frame variable in an array, and use CURRENTCLIENTID as index into the array to get what you want. The CURRENTCLIENTID is assigned to new users automagically by the Visu Management.
Last updated: 2024-03-14
Post by xabier on See only variable
CODESYS Forge
talk
(Post)
I have declarated this variable...When i use the variable I see all...I wan see only the variable not all. For example I declarated in GVL_GLOBAL ==> Torque_Mode When I push enter insert in code all rute..GVL_GLOBAL.Torque_MOde...I want see only torque mode...How is possible resolved this problem?? Thanks XABI
Last updated: 2024-03-14
Post by thewizard8 on Raspberry PI4 Serial Port
CODESYS Forge
talk
(Post)
Hi All, I finally figured out how to solve it. The only away that I got it to work was to define parity to None on modbus configuration, and now works like a charm. Just for the record I'm using the GPIO port pins (8,10) and a RS485 to ttl shield that you can find online. Thanks all for the support! Regards Ricardo
Last updated: 2024-03-19