Post by chir on SMC_REGULATOR_OR_START_NOT_SET issue
CODESYS Forge
talk
(Post)
Hello everyone! I faced the error SMC_REGULATOR_OR_START_NOT_SET using InoProShop (Inovance IDE). This error occured then I enable MC_Power block. The output BUSY is TRUE constantly.. The description of this error in documentation - "Controller enable not done or brake applied". Maybe someone know how to solve this problem
Last updated: 2024-04-19
Post by dkugler on I want to convert a WORD to a hex string like 15.432 to '3C48'
CODESYS Forge
talk
(Post)
you try to convert a WORD with BYTE_TO_HEX directly? Using https://de.helpme-codesys.com/ lead to the SM3_shared lib. There is a function: https://content.helpme-codesys.com/en/libs/SM3_Shared/Current/SM3_Shared/StringFormat/Word_To_HexString.html
Last updated: 2024-04-19
Post by stulle on 3.5 P20 hangs - no response
CODESYS Forge
talk
(Post)
Hello everyone, I have a problem. Codesys 3.5 P19 works without any problems. However, P20 is not usable, after starting it hangs "no response". A new installation didn't help either, unfortunately I can't find a more precise error. BR
Last updated: 2024-04-21
Post by eschwellinger on Cannot install Codesys control Multicore in raspberry pi 4
CODESYS Forge
talk
(Post)
just add in /etc/CODESYSControl_Usr.cfg [CmpRasPi] Architecture=armv7l for the 32Bit MC version... this is what this dialog does (or at least should do)
Last updated: 2024-04-22
Post by valenting on Problem with Licenced Software Metrics
CODESYS Forge
talk
(Post)
Hi, I can't compile my code with SP20, but when I use the "read current metrics from device" with SP20 I get the following, with "not yet supported" for the visualization part Is it supposed to be like this ?
Last updated: 2024-04-24
Post by reinier-geers on License problem gateway
CODESYS Forge
talk
(Post)
By browser is not working. Tim suggestet to use Codesys and stick in the laptop. Thats working. But now with a stick with licence but no running motion.
Last updated: 2024-04-25
Post by k2saki on CNC / G01 Speed is very slow (or go-stop motion) in Continuous short segment .
CODESYS Forge
talk
(Post)
I'm using CAD/CAM that outputs GCode with G01 many short segments from NURBS Curve, only X-Y axis. But CODESYS CNC motion seems much slower ( or stop-go motion ) in simulation mode than F-Value (I checked value from SMC_Interpolator - dVel ). In GCode G01, F value is F500, but movement is very slow, actual speed (dVel) is between 0 to 30 back and forth. I think very old CNC can move like that, but nowadays, a lot of CNC can move smoothly to process free curve ( somethimes option switch ) I tried to use G51 Dxx but I got the same result. My questions are 1) How do I improve CODESYS CNC motion in this case ? 2) How can I graph the sampling from dVel of SMC_Interpolate in CODESYS? From my GCode N2006 G01 X1.4364 Y-14.6847 F500 N2007 G01 X1.6759 Y-14.6768 N2008 G01 X1.9152 Y-14.6486 N2009 G01 X2.1547 Y-14.6400 N2010 G01 X2.3943 Y-14.6090 N2011 G01 X2.6336 Y-14.6002 N2012 G01 X2.8732 Y-14.5716 N2013 G01 X3.1127 Y-14.5634 N2014 G01 X3.3520 Y-14.5410 N2015 G01 X3.5915 Y-14.5336 N2016 G01 X3.8308 Y-14.5307 ... Thansk.
Last updated: 2024-04-29
Post by gseidel on CNC / G01 Speed is very slow (or go-stop motion) in Continuous short segment .
CODESYS Forge
talk
(Post)
Hi k2saki, 1.SMC_ReadNCFile2 2.SMC_Interpreter 3.SMC_SmoothMerge 4.SMC_SmoothPath 5.SMC_CheckVelocities I attached a simple example project. Best regards, Georg
Last updated: 2024-04-30
Post by davelewis104 on J1939 SA
CODESYS Forge
talk
(Post)
I am curious if there is a function block or function that will allow me to monitor the J1939 CANBus and pull out all of the SAs that are on a particular bus, without having to have them loaded in the J1939 manager?
Last updated: 2024-04-30
Post by eschwellinger on OPC Da Server Code Meter Issues after Enabling License
CODESYS Forge
talk
(Post)
it is mandatory to activate the OPC DA license into the 32-xxxxxx legacy container (not UFC) you need a remove ticket -> contact CODESYS store - my question to move the license
Last updated: 2024-05-03
Post by bryandimino on OPC Da Server Code Meter Issues after Enabling License
CODESYS Forge
talk
(Post)
Additionally the license is loaded on the soft storage for my device but it shows up as invalid. I just activated it today.
Last updated: 2024-05-02
Post by tama00 on GPIOs not running with Raspberry Pi 4 (and SPI connection)
CODESYS Forge
talk
(Post)
Hello everyone, I have a working SPI connection (with transferExt) between a Raspberry master with Codesys and an ESP32 slave. I would also like to use a few GPIO pins. Is there a problem with using SPI AND GPIOs? Environment: Raspberry Pi 4+ with Raspian from Oct 23 Codesys V3.4 SP19 Patch 5 with Runtime Version 4.10.0.0 Device: GPIOs B+/Pi2 My problem: The status is displayed as “GPIOs : not running”. And also during mapping the message “The bus is not running. The values shown are perhaps not actual”. However, the variable changes that I make in my program are displayed under “Current Value”. In the Logic Analyzer, the pin toggles during transmission with small intervals of +-4us (seems to be a cyclical disorder, but I don't know where exactly it could be coming from). This applies to pins that I actually use (output) but also to the other GPIOs (not used). With GPIO 4, the line remains permanently high. Attached is a screenshot from the Logic Analyzer. Channel 1,3,5 were GPIO pin 26, 22, 17 Would be very grateful for help. Best regards
Last updated: 2024-05-06
Post by tvm on Timer On Vijeo
CODESYS Forge
talk
(Post)
Vijeo doesn't support TIME variables, so the easiest thing to do is convert to a STRING in your program, and use that variable. You could use TimeAsString:= TIME_TO_STRING(TimeVar) to get a string that looks like this: T#5h10m45s200ms
Last updated: 2024-05-07
Post by pasillalej on No gateway with the given settings could be found
CODESYS Forge
talk
(Post)
Go to Online>Communication Parameters...>Gateway>TCP/IP> Click on "New..." and reestablish your connections with whatever IP address and set up information you have. Bypass whatever is necessary as you may have to redownload to the PLC.
Last updated: 2024-05-09
Post by stiller on OPC-UA ApplicationUri / ProductUri
CODESYS Forge
talk
(Post)
Hello! Is there a way to change ApplicationUri and ProductUri of the OPC_UA server? I can not find any information about it. Does someone have a clue? Thank you in advance!
Last updated: 2024-05-10
Post by dalfaro21 on Softmotion not working with simulation mode
CODESYS Forge
talk
(Post)
I have a KEB combivis studio software running codesys and I want to make some moves but softmotion is not working on my laptop I hope you can help me!
Last updated: 2024-05-12
Post by kevinm on Data source and safety PLC
CODESYS Forge
talk
(Post)
I am having the same trouble. However, if I change the Login Configuration settings to 'Type: Login using the credentials determined at runtime' then the Connection information continues as 'Connection state: Connecting' and 'Error information: OK'. There is no User Management on the source PLC.
Last updated: 2024-05-16
Post by rafaelbrito on Licensing info not available.
CODESYS Forge
talk
(Post)
Hello, I'm having the same problem. I'm trying to license Codesys running in a Linux container, which I downloaded from the following link (https://hub.docker.com/r/hilschernetiotedge/codesys_control_sl_linux). The same error that you mentioned appears. Is there any solution?
Last updated: 2024-05-22
Post by tortilla on J1939 connection between two devices
CODESYS Forge
talk
(Post)
Hey, I'm pretty new to CoDeSys so I don't know a lot of things yet. I have to create a connection between two devices (CANbus - J1939 connection). The idea for now is to send a message from one to another (one operates on 3.5 SP11 the other one on 2.3) I watched a few videos, worked with the documentation and worked with chatGPT 4o and was able to build the attached file. This part is about the device on 3.5.11: I'm using the J1939LocalECUDiag, TransmitParameterGroup, TransmissionTrigger Function blocks to send the message but my TransmitPG.xBusy / .xDone never turns to True and therefore my message is not sent while TransmitPG.xExcecute is True. I added the two devices in the CANbus in the J1939Manager and addapted the options like I've seen in the documentation. Can anyone explain what's wrong with my code in this casse or give me advices how to properly create a connection between my two devices? Thanks in advance!
Last updated: 2024-05-23
Post by donm on Regarding trend storage access error
CODESYS Forge
talk
(Post)
i have created a project which contain 30 trend and suddenly trend recording is not working. its showing an error 30437."Determination of root pages for recording did not work for 'screen', error:30437" how to solve this issue?
Last updated: 2024-05-27
Post by donm on trend storage access error
CODESYS Forge
talk
(Post)
i have created a project which contain 30 trend and suddenly trend recording is not working. its showing an error 30437."Determination of root pages for recording did not work for 'screen', error:30437" how to solve this issue?
Last updated: 2024-05-27
Post by zer0g on Modbus Client Request Not Processed
CODESYS Forge
talk
(Post)
Hi, I have the same problem as the guys above. Any solution or hint in the right direction is appreciated. Codesys version 3.5.19.2, Lib version: 4.4.0.0. Thank you!
Last updated: 2024-05-29
Post by jaspergain on Non-existing identifiers
CODESYS Forge
talk
(Post)
Hi, I'm using SP19 Patch 5, the software is also updated from SP18 Patch 5, I forgot to mention this. I will try a newer patch to see if it fixes the issue. Thanks for your help.
Last updated: 2024-05-30
Post by culius on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED
CODESYS Forge
talk
(Post)
Hey Guys, could you give a explaination of how to change the g_udiMaxPacketSize from 6000 to 100000 and g_udiMaxPayloadSize from 4096 to 80000 ? When I go to the library the parameter is not editable. I would really appreciate it :) Kind Regards
Last updated: 2024-06-07
Post by fajean on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
I have a Raspberry Pi 4 we have been using for years to run CODESYS for development purposes. I recently have had to re-install the OS (Raspberry OS lite). The only change to the default configuration is not creating the "pi" user during install. I (apparently successfully) installed the 4.10.0.0 control on the Raspberry Pi. We have licences on a dongle. I am able to start the control. systemctl status shows it as running for a little while (exactly, precisely 30 seconds as per my tests, every time), then it becomes exited. I can restart the control, and the same thing happens again. Every time. In the brief moments it is running, I can log in to the PLC. Working fast and restarting the control many times, I have been able to configure users. I have been able to download my application. I have been able to run the application, and stop on a breakpoint. I have been able to connect with the licence manager and confirm the dongle is detected and licences are listed as OK. I see nothing wrong until the service just exits. I have found nothing in the logs. It is like the runtime just terminates with no error code or message after exactly 30 seconds. Any help would be appreciated.
Last updated: 2024-06-13