Post by phoward131 on Alarm filtering latch variables
CODESYS Forge
talk
(Post)
I am having the exact same issue and was wondering if you ever found the problem? The sample program does exactly what it's supposed to with filtering but when I implement it the exact same way in my program, the alarm list just goes blank when I attempt to apply a filter.
Last updated: 2024-10-28
Post by pixsys on loading delay with the option "check client animations and overlay of native elements"
CODESYS Forge
talk
(Post)
Hi, the option "Support client animations and overlay of native elements" needs a very powerful graphics accelerator in the system. I'm using the Pixsys srl "TC series" HMI with the code "P3" (so a 4+4 cores CPU) that runs very well also with this option active.
Last updated: 2024-11-06
Post by hemuv on Open Numpad with VU.FbOpenDialogExtended
CODESYS Forge
talk
(Post)
Hello Barton, I try to log the changes in Numpad (upon Ok button pressed) that an Element name/Element text variable is changed from so to so. How to get the Element name (or text fields Text Variable) from where the Numpad is called? Numpad is Invoked from Inputconfiguration->onMouseDown->Write a variable. Thanks
Last updated: 2024-11-07
Post by bjarne-pagaard on Newly created texlists wont appear in the selection dropdown
CODESYS Forge
talk
(Post)
I just had the same problem in 3.5 SP19 Patch 6. Trying to use a textlist for Combobox Integer element. The textlist cannot be selected in the IDE, and is not found when manually entering the name. The textlist is copied to the device, but is not used. Can confirm, that copying an existing textlist and renaming it does work.
Last updated: 2024-12-16
Post by timvh on Colors look different when logged in and running
CODESYS Forge
talk
(Post)
At the top of the Visualisation Properties View, you can enable the "Advanced" options. This will give you access to more properties than what you currently see. There might be a variable linked to the "advanced" colour property where the fill colour is determined by the value of this variable (dword).
Last updated: 2025-01-09
Post by timvh on TargetVisu started in windowed or not full screen
CODESYS Forge
talk
(Post)
In your soft plc folder, there is a file called targetvisuextern.cfg. Open this with a text editor to change the settings. Remove the semi-colons in front of the lines to enable your custom window settings. WindowType=0 means you will get a moveable window. Save the file and restart the soft PLC to enable these settings.
Last updated: 2025-02-26
Post by jkopicz on How can you get the active frame index from a frame
CODESYS Forge
talk
(Post)
In my project, I have frames that I would like to read the current active index. I change the frame index using the onclick properties of a button, then change frame index. I need to do some logic based on which frame index is selected. Is there a way to read the current active index of a frame?
Last updated: 2025-03-11
Post by peterkcontrols on Making a Visu Element normally invisible and visible if variable is true
CODESYS Forge
talk
(Post)
Hello I would like an element in my visu to be only visible when a certain Variable is true, currently it is only capable of being normally visible and then invisible if a certain variable is true. Is this possible without programming a new variable to be the opposite of my desired control variable? Thanks.
Last updated: 2025-03-12
Post by jampid on PersistentVars and Webvisu Element
CODESYS Forge
talk
(Post)
Bonjour, est-ce que les espaces de noms des variables sont bien indiqu dans les commutateurs ? Je viens de faire un petit essai: OK {attribute 'qualified_only'} VAR_GLOBAL PERSISTENT RETAIN xBit1: BOOL:=1; xbit2: BOOL:=1; END_VAR Déclaration de variable dans le commutateur (et aussi dans un voyant pour le test) :PersistentVars.xBit1 Bon développement!
Last updated: 2025-04-07
Post by zoppp on Visu Frame-configuration___text will not work
CODESYS Forge
talk
(Post)
Yup, I've been having the exact same issue. A workaround that was working until Visu 4.8.0.0 was using TextList as the type in the frame configuration and then wrapping the text in quotes when configuring it. Im not sure if it will work with variables and I know it does not work if the type is text.
Last updated: 2025-06-17
Post by davidbo on How do I stop/start logging in my code using AC_Datalog with composer
CODESYS Forge
talk
(Post)
I have on my Pi successfully deployed an application to which with composer AC_Datalog is added. It starts logging automatically. I want a Visualization with a start/stop button controlling the logging. That must be easy. How do I do that?
Last updated: 2025-07-07
Post by installwhat on Opc remote alarms on Linux box
CODESYS Forge
talk
(Post)
It seems that the hmi sl license only works with windows. If i'm happy using web visu, rather than target visu, is possible to use remote opc-ua remote alarms without the hmi sl? Maybe it can be included in a different license that works on Linux? thanks
Last updated: 2025-07-16
Post by timvh on IECStringUtils.FormatDateTime
CODESYS Forge
talk
(Post)
There has been a fix in SP21. I tried it in this version with the option "Use unicodestring" enabled in the Visualization Manager and it worked if the variables used for the function are declared as WSTRING variables wsFormat : WSTRING := "%t[HH:mm:ss dd.MM.yyyy]"; wsTime : WSTRING; IECStringUtils.FormatDateTime(cbpResult := ADR(wsTime), uiResultCapacity := SIZEOF(wsTime), cbpFormat := ADR(wsFormat));
Last updated: 2025-07-29
Post by jcarter on Webvisu Combined Authentication
CODESYS Forge
talk
(Post)
Is there a way to have both a Public No Login Screens with Screens that do require login and File Transfer? My Idea is to have the default page be View Only with a Login Button in the Corner and then Once Logged In you can change settings and download files depending on your user group.
Last updated: 2025-08-28
Post by beavel on Opening and saving files with fileOpenSave dialog
CODESYS Forge
talk
(Post)
1 + Replying in hopes of getting an answer here. I would also like to modify the look of the FileOpenSave Dialog. I have successfully adjusted the looks of the User management Dialogs but can not find a library file to adjust this particular one. Any help would be helpful. @thk @eschwellinger @sheberle .
Last updated: 2025-09-08
Post by dogulas on numeric text box control
CODESYS Forge
talk
(Post)
Ok, this is how I made a numeric text field: use a Text Field properties -> Texts -> Text := %f (or %d or whatever you need) properties -> Text variables -> Text variable := (your numeric variable) properties -> Input configuration -> OnMouseDown -> Configure: Write Variable Input type := VisuDialogs.Numpad Use another variable (your numeric variable) Min val Max val etc. Please tell me there is an easier way to do this.
Last updated: 2025-10-02
Post by rene2 on How can you get the active frame index from a frame
CODESYS Forge
talk
(Post)
I think I struggle with the same issue. I tried the currentVisu variable but this is the active Visualisation. I have a dialog with a frame with frame configuration like in the picture. I would like to use the index te be used to make a button look like it's pressed/selected.
Last updated: 2025-10-14
Post by nima-khajehali on Touch Issues in Tablet (HMI)
CODESYS Forge
talk
(Post)
Hi Everybody, I download the Visualization on the Dell tablet as HMI. The button of HMI does not work with any touches. However, the buttons is working well with a plugged in mouse. Is there any configuration in Visu. manager or setting that I can modify? (Latitude 7230 Rugged Extreme Tablet) Please help me.
Last updated: 2024-02-08
Post by dkugler on Color Change for Symbols not working
CODESYS Forge
talk
(Post)
to modify and change the color of this icons from symbols lib I placed it in a visu. After download to the device, I uploaded the SVG files and saved it local. Now I was able to modify them with inkscape and import it to my own imagepool in the project :-)
Last updated: 2024-02-13
Post by liepgp on Batch printing
CODESYS Forge
talk
(Post)
I'm searching a way to print several projects to PDF, in order to correct student exercises. I'm able to open the printing dialog box using system.commands["print", "print"].execute(). But I can't find the prompt names in order to complete the printing with the dialogs Do you have any way to do that?
Last updated: 2024-02-13
Post by aarondw10 on Use element properties
CODESYS Forge
talk
(Post)
Assume I have a rectangle named rec1 from which I want to use the coordinates of the upper left corner. Is there a way to links these X and Y values from the properties to an integer defined in the main program? Note that I just want to use them and not change any of these coordinates in the program.
Last updated: 2024-02-29
Post by macros8 on Viewing PDF in WebBrowser Visual Element
CODESYS Forge
talk
(Post)
My experience is that opening pdf file is very dependent on which browser is used. I have tried a couple of them and only Mozilla Firefox has opened file correctly in same screen. All other browsers face some issues. Therefor I had to flip my pdf to txt which has not been nice solution.
Last updated: 2024-03-01
Post by reinier-geers on Swap Output in frame
CODESYS Forge
talk
(Post)
How can i swap an output in a frame ? Ive got a frame of a mixer. use this twise. I want to turn these on and of. i can Get in the frame as dwAdr_Mixer : DWORD; . as Var_IN_OUT. Then Adress as Adr(Output ) But in the frame i cant swap dwAdr_Mixer^ :-= not dwAdr_Mixer^ ;
Last updated: 2024-03-11
Post by kirsipr on Color of empty table and table header
CODESYS Forge
talk
(Post)
I have managed to change my dynamic visu table colors with the template for each column to dark like my rest of the webvisu background is. How ever the empty table (when not populated) and the table header stays white / gray. Is there same way to modify the colors of header and empty table?
Last updated: 2024-03-13
Post by bjarne-pagaard on Multiple WebVisu
CODESYS Forge
talk
(Post)
You can use the switch frame variable, but there should be a variable for each active visu user. You can put the switch frame variable in an array, and use CURRENTCLIENTID as index into the array to get what you want. The CURRENTCLIENTID is assigned to new users automagically by the Visu Management.
Last updated: 2024-03-14