Post by imdatatas on Problem with edge gateway config mode CODESYS Forge talk (Post)
I encountered the same problem. (Windows10 x64 single language OS). As @eschwellinger mentioned, I uninstalled the latest EdgeGateway version and installed version 3.5.20.0. Now, when I right-click and select "Allow Edge Gateway...", Config mode is activated without any error or warning window and I do not need to manually type [CmpEdgeGateway] for EdgeGateway version 3.5.20.0.
Last updated: 2025-02-04

Post by timvh on Reading multiple lines from csv file CODESYS Forge talk (Post)
Not sure, but maybe before you enter step 5, set i, lineindex and charIndex to 0. And the buffer variable should have a size bigger than 1 line. Additionally I think you should set bufferstart to 0 before you enter step 5. And in the OSCAT function you always point to the buffer address, but shouldn't this be (buffer + bufferstart)?
Last updated: 2025-07-23

Post by dkugler on Color Change for Symbols not working CODESYS Forge talk (Post)
to modify and change the color of this icons from symbols lib I placed it in a visu. After download to the device, I uploaded the SVG files and saved it local. Now I was able to modify them with inkscape and import it to my own imagepool in the project :-)
Last updated: 2024-02-13

Post by kirsipr on Color of empty table and table header CODESYS Forge talk (Post)
I have managed to change my dynamic visu table colors with the template for each column to dark like my rest of the webvisu background is. How ever the empty table (when not populated) and the table header stays white / gray. Is there same way to modify the colors of header and empty table?
Last updated: 2024-03-13

Post by fefefede on Error C0521 - unknow compiler CODESYS Forge talk (Post)
Hello and thanks for reply. I not have "Libray Manager" on "Update Device". I not try to open project but i open Codesys and then create a new project and when try to generate code i have the error :/ I notiche a strnge situation. I have two different software on my pc: CODESYS V3.5 SP15 Patch 4 (with this my new program not work but can open and work with some course example); CODESYS V3.5 SP19 Patch 2 (with this my custom program work) Wich version i must be choose? Why i have two different version? Thanks
Last updated: 2023-09-02

Post by teichhei on The selected container ... does not fit your ticket CODESYS Forge talk (Post)
Hi, When trying to activate a control Basic L license on a Wago PFC200 750-8203 the error The selected container ... does not fit your ticket comes up and won't allow licensing. I have deleted the /var/opt/codesys/cmact_license/ content 3 times and the container number changed each time after a reboot, but the problem persists. Not a happy first time experience with those weird application based licenses. IDE is 19.20. This was a e!Cockpit FW22 PLC and I used Deploy Control SL to make the green web interface red. WBM shows Codesys 2 and e!Runtime active which is a bit weird. What do I do now? Regards Heinz
Last updated: 2025-01-08

Post by atone on CAA File Handling: "Read only" error CODESYS Forge talk (Post)
In case of error while opening the file to read you assume that the file doesn't exist and try to create one. But it could be that the SD card is not ready yet or simply not there. I would try to check first if the SD card is there and accessible. Otherwise with FILE.Create you could end up creating a new directory that is not mapped to the SD card. This would explain the errors even after a reboot, though it doesn't explain the READ_ONLY_CAA error I guess? I would use FILE.DirOpen and FILE.DirList to check if the SD card is there and ready.
Last updated: 2025-03-20

Post by dhumphries on Not able to see input data coming from eip adapter on codesys CODESYS Forge talk (Post)
Does the device have a green icon next to it when the PLC is running? If not you have some kind of communication problem, wireshark may be picking up some data but the scanner may not be configured correctly to receive the data. Check the T>O and O>T bytes and make sure they match on both the scanner and adapter. I've had very little success loading a .eds file and having the configuration work without some manual configuration. If you have a green icon, have you enabled the device to always update variables?
Last updated: 2024-03-02

Post by fajean on CODESYS control on RPi starts, shortly runs, then exits CODESYS Forge talk (Post)
4.11 appears to solve the problem. Thanks for your help. I had first installed the 64-bit version of RPiOS, but looking at various posts and the product's page on the store which only lists 32-bit compatibility, I downgraded to the 32-bit version. I did this before trying 4.11, and it did not solve the problem. Thus my working system is 32-bit, and I am wondering if I can go back to 64-bit or not. An 64-bit OS is not listed as compatible on the store's web page, but when installing there actually is a 64-bit version listed (automatically chosen when installing on 64-bit, but otherwise greyed out). Is 64-bit supported and the website is out-of-date, or is that some kind of work-in-progress?
Last updated: 2024-06-13

Post by tali on Configuration of disabled/deactivated visu elements CODESYS Forge talk (Post)
would be great to have such fucntionality. Sometimes it is not clear for user which elemetns are blocked and which are not - the greyed out eleemtns are not so different for low resolution / low quality screeens. What I have in my mind as well is to have a possibility to detect the visu Element clicked on and get its Access Rights. If it is blocked/deactivated, the dialog can be rised with INFO 'please login first with proper rights'. It is possible now to have a Mose event Handler ( Examples -> EventHandler) and rise the dialog out of ST (Exapmpals -> ST Dialogs). I am struggling still with getting the separate Visu Element under the mouse and its structure info
Last updated: 2025-12-05

Post by pernockham on Gateway in China - "Gateway not connected" CODESYS Forge talk (Post)
I think I understand my problem. They are most probably related to configuration of the network. When I use DHCP for the unit to my router it all works. However when using static IP I have not managed to reach functioning state. Trying to replicate the situation on my desk. Having a static IP on the "debian host" and a connection to my computer which then routes traffic on to internet. I have entered settings for gateway and netmask. I can ping from my "debian plc host" to internet and also do "curl google.com" so traffic seems to find its way through and back, still "Automation server" will not find the gateway. Any hints how a manual configuration should be done? Is it possibly a "firewall" issue of my "normal router"? Thanks for any help! Per
Last updated: 2026-01-27

Post by narius on OPC-UA object instances preexisting in imported xml information model CODESYS Forge talk (Post)
Hi all, is it possible to use object instances that are not instantiated by codesys itself, e.g. have been defined in UA-Modeler ? When I browse the plc with UA-Expert I see those instances, but I have not seen information in codesys or the web if these are writable in codesys. So far, I am under the impression, that it is not possible, but would like to hear from others. Also, is it correct, that it is not possible to create references inside codesys ? Thanks in advance and kr
Last updated: 2024-08-08

Post by davidbo on All the things needed for anonymous login to OPC UA CODESYS Forge talk (Post)
When you have a deep object structure where not all values are not exposed to OPC UA, the top object will not have a V check mark but be filled fully out. In that case CODESYS do not always registrate changes to inner object. Solution set a V in the checkbox of the top object, build, download. Now you can browse, but all values in the top object will be selected, then you can deselect the ones you don't want, build, download and it works
Last updated: 2025-09-10

Post by mgengler on Recipe Manager - Not Creating Recipe Files CODESYS Forge talk (Post)
Recipe Manager will load windows explorer view and allow file name to be typed in or existing file selected but will not create a new file or overwrite an existing. Will not create a file in the default folder or even a defined folder like "c:\recipes\" although it does properly navigate to that folder location. I made sure the folder is not read-only. Can't figure out what is missing...
Last updated: 2024-05-17

Raspberry Pi Control SL MC - Restoring License not working anymore! CODESYS Forge talk (Thread)
Raspberry Pi Control SL MC - Restoring License not working anymore!
Last updated: 2023-08-24

SPI Master not running/MCP3008 Missing driver. CODESYS Forge talk (Thread)
SPI Master not running/MCP3008 Missing driver.
Last updated: 2023-09-13

Japanese characters are not displayed in webvisu CODESYS Forge talk (Thread)
Japanese characters are not displayed in webvisu
Last updated: 2021-03-25

CODESYS Control Not Showing Up in Devices CODESYS Forge talk (Thread)
CODESYS Control Not Showing Up in Devices
Last updated: 2023-01-02

Modbus: dis- / re-connect cable: modbus does not re-start CODESYS Forge talk (Thread)
Modbus: dis- / re-connect cable: modbus does not re-start
Last updated: 2013-09-28

IVisualizationDialog.SetInterface does not seem to work at all CODESYS Forge talk (Thread)
IVisualizationDialog.SetInterface does not seem to work at all
Last updated: 2022-04-05

CoDeSys SP Win V3 - Soft PLC Does not start. CODESYS Forge talk (Thread)
CoDeSys SP Win V3 - Soft PLC Does not start.
Last updated: 2010-11-17

Visualization "F" Key not Reseting Variable CODESYS Forge talk (Thread)
Visualization "F" Key not Reseting Variable
Last updated: 2018-01-18

The required device description is not installed.. CODESYS Forge talk (Thread)
The required device description is not installed..
Last updated: 2023-10-03

USB <-> CAN, CANfox, Component CmpCANFoxDrv NOT loaded CODESYS Forge talk (Thread)
USB <-> CAN, CANfox, Component CmpCANFoxDrv NOT loaded
Last updated: 2023-10-16

Persistence Manager does not save alphabetically first value CODESYS Forge talk (Thread)
Persistence Manager does not save alphabetically first value
Last updated: 2023-10-17