Post by micik on False Notification Application Error with raspberry pi 4
CODESYS Forge
talk
(Post)
Hello, I have just went through all steps shown on Codesys YT channel https://www.youtube.com/watch?v=RPoPscbo3Kc And it works, I have installed PI OS 32 bit and choose Single Core. However, immediattely when I create standard project with Raspberrz pi device, "Application" is underlined, like there is an error, but in reality there are no errors, and I cannot see what are these 3 messages like shown in attachment. Aside for this red underline, everything seems to work fine. How to correct this? Thank you! Update: I have found what errors are, but not sure how to correct them: Identifier 'IoDrvGPIO' not defined Function block 'IoDrvGPIO' must be instantiated to be accessed 'IoDrvGPIO' is no component of 'IoDrvGPIO'
Last updated: 2024-09-03
Post by trusty-squire on How to revert to previous version library
CODESYS Forge
talk
(Post)
Hi, I'm experiencing a bug with the latest version of SoftMotion CNC library (4.17), where the 3DPath object in Visu is missing all the important properties. I've verified that a previous app I was working on with library version 4.16 did not have this issue and the issue is duplicated in that project when I update it to 4.17. I've already submitted a bug report, but for the time being I need to revert the project I'm currently working on back a revision. I've tried right clicking on the library but the option to select the version is greyed out. Can anyone help me?
Last updated: 2024-09-05
Post by pierre on difference between stub file and source file in scriptengine
CODESYS Forge
talk
(Post)
I included the stub files of scriptengine (codesys python api) in a directory scriptengine of a project. I tried to include librarymanager like that: from scriptengine import librarymanager visual studio code detected an error. It said librarmanager could not be found. Indeed in the stub file, this was library_manager. But if I change it in my code, the plugin doesn t work anymore. I found an easy solution to this problem. I ve just changed the copied stub files.(library_manager -> librarymanager) But I think it would be better if you update it yourself in the future.
Last updated: 2024-09-20
Post by pierre on difference between stub file and source file in scriptengine
CODESYS Forge
talk
(Post)
I included the stub files of scriptengine (codesys python api) in a directory scriptengine of a project. I tried to include librarymanager like that: from scriptengine import librarymanager visual studio code detected an error. It said librarmanager could not be found. Indeed in the stub file, this was library_manager. But if I change it in my code, the plugin doesn t work anymore. I found an easy solution to this problem. I ve just changed the copied stub files.(library_manager -> librarymanager) But I think it would be better if you update it yourself in the future.
Last updated: 2024-09-20
Post by rmaas on TargetVisu for Linux SL not starting
CODESYS Forge
talk
(Post)
Hello, I am trying to get TargetVisu for Linux working but i am having some troubles. The problem is that after installation it is not starting automatically on boot and i cannot start it from the update Targetvisu tool. When i try i get the following error (see attached screenshot) The file /opt/codesysvisualization/scripts/codesysvisualization_start.sh is missing... Steps performed: - installed fresh Debian 12.7 on virtual machine - installed all required libraries as described here: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_target_visu_for_linux.html - then installed the TargetVisu for Linux SL 4.13.0.0 using the Codesys IDE Does someone know how i can fix this? Best Regards, Rinie
Last updated: 2024-10-02
Post by yoeri on Refresh visulization realtime
CODESYS Forge
talk
(Post)
Hi everyone, I need some help with displaying an image (test.png) on my device. Initially, showing the image is straightforward. However, I want to be able to update the image dynamically. My goal is to send updated files via FTP to the device, and have the display automatically show the latest version of the image. All images will be sent with the same name (e.g., test.png). Currently, I can see the updated image after sending it via FTP and performing a warm restart, but I'd like to achieve this in runtime, without having to restart the display or application. Does anyone have suggestions on how to implement this? Thanks in advance!
Last updated: 2024-10-21
Post by cdutz on Problems connecting to Codesys 4.9.0.0 runtime on my Wago PFC200
CODESYS Forge
talk
(Post)
Hi all. I am currently struggling to get my Wago PFC200 running the Codesys Runtime in version 4.9.0.0 working. I am using Codesys V3.5SP19. I updated the PFC200 to the firmware version 04.01.10(23) after having tried the latest version (04.03.03(25) from Wago and not being able to start the runtime. After reading version 23 was needed, I changed to that and at least was able to have it start the codesys runtime. I also installed the "Codesys Control for PFC200 SL 4.9.0.0" plugin for Codesys to install the Codesys runtime in version 4.9.0.0 as well as update the Gateway on the device. While I seem to be able to connect to the gateway on the PLC (the dot is green) and when doing a scan, I do now find my PFC200, which is a huge improvement to before, where with firmware version 25 it just failed to start the runtime and I never found any device when doing a scan. Unfortunately I don't seem to be able to connect to the PLC in codesys. I logged in via SSH and changed the password and I can see that this password is correct as the stuff in the Codesys PFC200 tools tab only works if I use my changed password. And I used those credentials to update the installed Runtime version, which the log claimed to have worked fine. Now whenever I try to connect to the device found in the scan, I get a authentication pop-up with empy device name, device address: 000A. As User I use "root" and as password the password that I changed it to. As a response I just get "Ungültige Benutzerauthentifizierung auf dem Gerät" (Eng. probably something like "Invalid user authentication on the device". What could I be doing wrong? Admittedly I'm a bit lost here :-/ Chris
Last updated: 2023-08-26
Post by thommy54 on CODESYSControl_User cfg richtig konfigurieren
CODESYS Forge
talk
(Post)
Hallo, nach Erwerb eines neueren Raspberry pi 4 (V1.5) musste ich zwangsläufig von Codesys 3.5.16 hochwechseln - ich habe auf 3.5.20.1 geupdated. Da schlugen mir plötzlich ne Menge Einschränkungen entgegen, deren Behebung einige Zeit dauerte. Eine davon ist, das ein SysFile.SysFileOpen nicht mehr funktioniert. Ich habe das Problem mit Einträgen in der /etc/CODESYSControl.cfg behoben: [SysFile] FilePath.1=/etc/, 3S.dat IecFilePath.1=/proc/, cpuinfo IecFilePath.2=/proc/, iomem PlaceholderFilePath.1=/sys/devices/w1_bus_master1, $OneWire$ PlcLogicPrefix=1 ; ; ---------------------- ; selbst eingefügt PlaceholderFilePath.2=/home/root, $my_home_root$ PlaceholderFilePath.3=/etc/init.d, $my_conf$ PlaceholderFilePath.4=/var/lib/mpd, $my_music$ PlaceholderFilePath.5=/root/Rasp_SPS_Filesystem, $my_Rasp$ Ob die Einträge sich etwas überlappen, kann mir gern jemand sagen, das ist aber nicht das Problem. Ich habe bei den vielen Versuchen, das Teil zum Laufen zu bringen, bemerkt, daß die Einträge auch ganz schnell mal verschwinden. Das ist ja auch so beschrieben, wenn die nächste Version kommt, sind meine Einträge weg. Da ich ähnliche Probleme mit dem Funktionieren von "SysProcessExecuteCommand2()" hatte, die ich ebenfalls mit Einträgen in die /etc/CODESYSControl.cfg hätte beheben können, habe ich gelesen, das man "private" Einträge lieber in die Datei /etc/CODESYSControl_User.cfg machen soll. Gesagt getan und "SysProcessExecuteCommand2()" lief: [SysProcess] Command=AllowAll Command.0=shutdown Aber auch irgendwo stand, das so ein Beteichner wie [SysFile] oder [SysProcess] nur einmal in den beiden Files /etc/CODESYSControl.cfg oder(!) /etc/CODESYSControl_User.cfg vorkommen darf. Das ist nun die eigentliche Frage! Ist das so ? Bei [SysProcess] ist das kein Problem, das gibt es in /etc/CODESYSControl.cfg nicht. Aber bei [SysFile] sieht das anders aus. Da sind 5 Zeilen schon in /etc/CODESYSControl.cfg drin. Würde ich diese in die User-Datei rüberschieben, könnte beim nächsten Update was fehlen oder, oder... Lasse ich es so wie es ist, sind meine Einträge beim Update weg - das sollte ja verhindert werden. Kann da jemand genaue Auskunft geben ?? Vielen Dank Thomas
Last updated: 2024-06-28
Post by adamrobotic on llcallback() iec exception caught cmpid=0x00000002, eventid=0x00010008
CODESYS Forge
talk
(Post)
Hi All, Recently I have been experiencing a issue in CodeSys SP16 Patch 3, with a exception which comes up after I have made several online changes. callcallback() iec exception caught cmpid=0x00000002, eventid=0x00010008, after I experience this fault then I receive a error message for any subsequent online change "online change failed, no task gap within 10000ms". To recover either the controller needs a orgin reset, which will allow online edits thereafter until falling back into the loop. I am using a TURCK TX707 product which is controlling robot trajectory, We have hard coded the coordinate data rather than using persistence variables so hence the need to do online changes consistently. I have read on the forum other people have experienced similar issue with the online task gap, but I have no task which have same priority and also monitored the CPU usage and have not seen it go above 13%. Anyones help would be much appreciated, thankyou.
Last updated: 2023-08-18
Post by sunfloweeerrry on Edgelogix-rpi-1000-cm4102032 SPI port connection to PiFace I/O Driver in CodeSys.
CODESYS Forge
talk
(Post)
Hello, I hv a problem. Couldn't solve this for 2 days now. So I'm quite new at CodeSys and I have to use the spi port x30 on the edgelogix rpi 1000. So what I have to do is just 'add device' at the SPI where I hv to pick the 'SPI master' after that I hv to change the parameters according to the edgelogix I did found in the spidev.h but nothing got updated so I 'add device' again where I pick the PiFace I/O Driver and I put my variables at the I/O Mapping, which i put the input startbit at the in part and led at the out part. I want to make the led blink according to my structured text code but somehow the hardware didn't connected with the CodeSys spi port. Nothing happens. Any idea what I have to do?
Last updated: 2023-08-18
Post by ofey on Codesys Soft PLC OPC UA server
CODESYS Forge
talk
(Post)
Hi! I'm sorry if this has been asked before. I have tried looking up previous topics regaring this, but even though I'm following tutorials and other posts I cant seem to get this to work consistently. I actually got the connection established on a test project after some trial and error. I only got it to work with the "Anonymous login". But after i deleted the test project and tried to get the same thing to work on another project I cant get it to work anymore. What I'm trying to do: Set up and OPC UA Server using CODESYS with the free soft PLC. I then try to connect to the OPC UA Server with the program "UaExpert". What happens: I get the error Error "'BadUserAccessDenied' was returned during ActivateSession". What I have done in CODESYS: - Added the object "Symbol configuration" and checked some test variables - Checked "Support OPC UA features - In "Communication settings -> device -> Change runtime security policy" I have checked "Allow anonymous login" What I have done in UAExpert: - Found the OPC UA server under "local". (It is showing two servers though, I do not know why. It showed the same when it worked yesterday). Se attachment - Checked "Anonymous" under "Authentication settings in the OPC UA server. I'm new to CODESYS, so it could be something elementary wrong in my settings. Maybe something in the user settings in CODESYS regarding user rights or something?
Last updated: 2023-09-14
Post by sturmghost on Visualization using methods and cyclic ST-calls
CODESYS Forge
talk
(Post)
Im looking for a way to implement ST-code into the visualization element without creating a helper POU or method in my device/application tree. Like visualization properties are evaluated at each VISU_TASK cycle I want to be able to create own ST code which interacts with the visualization interface variables. To be more specific I want to have a property which executes user defined ST-code at each VISU_TASK cycle exactly like its already possible for Input Configuration on various mouse and dialog events. Also a property for initialization (so only executed once) and a timed property would be nice. With the situation right now I'll have to create a POU function which handles the ST-code and misuse a property, like the text variable, to execute this POU function at each VISU_TASK cycle. Or does it exist and I don't know it?
Last updated: 2023-10-02
Post by ofey on Testing of Codesys program
CODESYS Forge
talk
(Post)
Hi! I thought to hear what you guys think is the best way to test the program in my scenario. I have some PLC programs that have been made and deployed on different PLC's. The program has added the specific devices and IO that is applicable. I have made a test environment for everything outside of the PLC, ie. the same SCADA system that is talking to the PLC, and a program running locally is simulating the plant (level regulation of different tanks). Pr. now I have had to manually change the variables that are reading/writing values from the IO so they read/write via OPC instead. I also have to change the device tree from the specific PLC rack, to the soft PLC. So I kind of end up with two different programs that I have to maintain. I was just wondering if you believe there is an easier way to do this. So I can have the exactly same program and kind of switch between the soft mode, and the "real" mode.
Last updated: 2023-12-07
Post by mavitia on Application based license problem - Modbus TCP
CODESYS Forge
talk
(Post)
I am running ubuntu on a raspberry pi, and installed an application based license Control Basic M on it, it runs a demo program fine, does not timeout etc. however, when I add a modbus TCP device, I start getting errors: <Entry severity="error" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:42 PM" infoId="24">Online change denied. Application Application is in exception state!</Entry> <Entry severity="error" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:42 PM" infoId="68">Download failed: Application=Application</Entry> <Entry severity="exception" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:41 PM" infoId="0">Application app=Application has invalid license metrics!</Entry> the modbus tcp slave runs, and the counter ticks up, however, when I call the variables on the %IX0.0 in my program, and try to upload the changes, I am getting the error messages which stop the program as far as I understand, the application based, M includes 2 fieldbus instances, but on the other side is fairly new, anything obvious I am missing out here?
Last updated: 2023-12-18
Post by toby on Ethernet/IP communication with Omron NX1P2
CODESYS Forge
talk
(Post)
Hey guys, I'm very much a noob with networking, it's my achillies heel, and this is my first networking project using Ethernet/IP. Any help offered is GREATLY appreciated. I'm trying to network a Codesys Project with an Omron NX1P2 PLC. I'm using EIP due to hardware restrains. I've added the fieldbus, EIP scanner (as the master), and made a Network Variable List. On the Sysmac Studio end, I've made the variables and set them to network inputs/outputs, registered them in EIP settings, but when I try to set the target device (the Codesys project), I suspect I need to import an EDS file for the EIP mapping. Back in the Codesys project, I'm not sure how to: - Make an EDS file to share with Sysmac Studio - How to link the target device (Omron PLC) to the EIP fieldbus - How to map the inputs from the Omron PLC. Im sorry for my very open request for help, i'm kind of lost looking through the various forums/video/tutorials as many of them dont match what im trying to do. Any help, or sample programs would be so so greatly appreciated. If you need any further clarifications, please feel free to ask. Thanks in advance, Toby
Last updated: 2024-01-24
Post by phoward131 on Alarm State Icon
CODESYS Forge
talk
(Post)
I am trying to create an icon on an overview screen that depicts if an alarm group has active alarms, active acknowledged alarms, or inactive unacknowledged alarms (waiting for confirmation). I've attempted to set up Notification Actions in the Alarm Class to set variables based on state changes but have been unable to find a clean and effective way to do this. Because an action on any alarm will trigger the variable to be set as instructed, I'm struggling to find a way to configure it for what I need (ie if two alarms activate, then one deactivates, the variable for indicating an alarm is active would be cleared after the single deactivation). I've been pointed toward the Alarm Manager example project but I'm finding it too complicated to understand how to implement it in my own project. Has anyone come up with another good way to indicate the states of alarms or a simpler usage of the Alarm Manager functions?
Last updated: 2024-04-23
Post by mxj262 on FB having single input but initialized with Array
CODESYS Forge
talk
(Post)
I am adding elements of an ARRAY using pointer to access each element inside a FOR loop and the FOR loop does not stop! What is the right way to use pointers in such case?? I have another loop that is not using pointer and it stops but the loop using pointer keep on adding. METHOD FB_Init: BOOL VAR_INPUT bInitRetains: BOOL; // TRUE: the retain variables are initialized (reset warm / reset cold) bInCopyCode: BOOL; // TRUE: the instance will be copied to the copy code afterward (online change) END_VAR VAR_IN_OUT // basically REFERENCE TO window_buffer: ARRAY [*] OF INT; // array of any size END_VAR THIS^.windowPtr := ADR(window_buffer[0]); THIS^.windowSize := UPPER_BOUND(window_buffer, 1) - LOWER_BOUND(window_buffer, 1) + 1; FUNCTION_BLOCK FB500 VAR_INPUT END_VAR VAR_OUTPUT END_VAR VAR windowPtr: POINTER TO INT; windowSize: DINT; currentIndex: UINT; element1:INT; element2:INT; i:INT; j:INT; sum:DINT:=0; END_VAR element1:=windowPtr[0]; // read the first element of the Array dynamic memorry element2:=windowPtr[1]; FOR i:=0 TO (TO_INT(windowSize-1)) BY 1 DO // this loop does not stop Sum:=sum + windowPtr[i]; END_FOR FOR j:=0 TO 5 BY 1 DO // this loop stops j:=j+1; END_FOR https://ibb.co/k3DhkZT
Last updated: 2024-05-06
Post by egau on Hard shutdown: no code on device after power on
CODESYS Forge
talk
(Post)
Hi, We have a machine running Codesys on a Windows IPC (CODESYS Control Win v3 - x64). When we hard shutdown the machine, the code on the PLC sometimes becomes "corrupted" after a power on (When trying to login to the PLC, we get the message "The application 'Application' does not exist on device."). I've noticed these errors in the logs, but I'm not sure what to make of them. We are not using any RETAIN variables in our code, although I'm not sure about referenced librairies. (we are using the persistence manager). I'm pretty sure that not doing a graceful shutdown is the root cause of this. This being said, what is the proper way of doing a graceful shutdown? Is putting the Codesys application in "stop" sufficient? I know how to implement this, so if it works then it would be a quick fix. However, I think we need to add a UPS, which would detect power loss and inform the PLC that it needs to initiate its shutdown, and then the PLC would shutdown gracefully. Any help with this will be greatly appreciated :)
Last updated: 2024-10-03
Post by annd on Migration von "CODESYS Control for PFC200 SL" zu WAGO FW26 "CODESYS V3.5.19.2"
CODESYS Forge
talk
(Post)
Ich hab's hinbekommen: Nach dem Controller Update hab ich ein neues Projekt gemacht und nur den PFC200(8212) eingefügt (es erscheint dann ein leerer Kbus und eine serielle Schnittstelle COM1). Dann hab ich mich am Controller eingeloggt und den Kbus (Rechtsklick: Geräte suchen) mit allen Modulen automatisch ergänzen lassen. Bei den leeren Modulen hab ich dann das E/A-Abbild in csv exportiert. Dasselbe hab ich bei meinem alten "PFC200 SL" Projekt gemacht. Und dann in Excel alle Variablennamen in die leeren csv kopiert und danach wieder im neuen Projekt importiert. Dann hab ich noch alle Programmblöcke, Tasks, Visualisierungen und auch Modbus TCP Master u. Slave und auch Modbus COM Port Master und Slave in das neue Projekt kopiert. Weiters hab ich alle notwendigen Bibliotheken im Bibliotheksverwalter eingefügt. Dann noch ein paar kleine Fehler korrigiert (ich musst einen anderen Block zum Lesen der Uhrzeit nehmen) bis ich das neue Projekt fehlerfrei übersetzen konnte. Dann konnte ich es auf den Wago Controller übertragen und direkt starten. Es sieht so aus, dass alles läuft. Gruß annD
Last updated: 2023-11-18
Post by open on How to create a stopwatch?
CODESYS Forge
talk
(Post)
Hi @ph0010421, I tried the program the TimeTaken is calculated when stop is triggered. I want the TimeTaken to be continuously calculated and counting when a BOOL variable is true. I tried to program this way: Declaration: PROGRAM PLC_PRG VAR bStartStop: BOOL := FALSE; // Start/Stop button bReset: BOOL := FALSE; // Reset button bRunning: BOOL := FALSE; // Flag indicating whether the stopwatch is running tStartTime: TIME; // Variable to store the start time tElapsedTime: TIME; // Variable to store the elapsed time END_VAR Implementation: // Main program logic IF bReset THEN // Reset button pressed, reset the stopwatch bRunning := FALSE; tElapsedTime := T#0s; ELSIF bStartStop THEN // Start/Stop button pressed, toggle the running state IF bRunning THEN // Stop the stopwatch bRunning := FALSE; ELSE // Start the stopwatch bRunning := TRUE; tStartTime := tElapsedTime; END_IF; END_IF // Update the elapsed time when the stopwatch is running IF bRunning THEN tElapsedTime := tElapsedTime + T#1s; // Adjust the time increment as needed END_IF However counting of the seconds is not accurate. I tried changing the main task cycle time interval to 1000ms. The counting of seconds become slower. (see attached) Please help
Last updated: 2023-12-08
Post by kevin123 on auto-answer dialog using system.prompt_answers
CODESYS Forge
talk
(Post)
I am trying to do "update device" in a project which was saved in a different version of CODESYS using ScriptEngine, a dialog with 'Yes' and 'No' button popped up showing that "Do you want to upgrade the storage format for this project? -if you click 'Yes', storage format will be upgraded... -if you click 'No', storage format will not be changed..." I have to click the 'Yes' button automatically by scriptEngine. I know from others topics here in forum, that some dialogs can be auto-answered using system.prompt_answers. And I also get the messagekey of this dialog: Key: "<< No Key>>" Message: "Do you want to upgrade the storage format for this project? - If you click 'Yes',... i have tried using the system.prompt_answers command below, but the dialog was not auto-answered. system.prompt_answers["<<No Key>>"] = PromptResult.Yes Does someone know how to auto-answer the dialog using system.prompt_answers command with messagekey"<< No key>>"? or any suggestions to solve this issue, Thanks!
Last updated: 2024-01-26
Post by kevin123 on auto-answer dialog using system.prompt_answers
CODESYS Forge
talk
(Post)
I am trying to do "update device" in a project which was saved in a different version of CODESYS using ScriptEngine, a dialog with 'Yes' and 'No' button popped up showing that "Do you want to upgrade the storage format for this project? -if you click 'Yes', storage format will be upgraded... -if you click 'No', storage format will not be changed..." I have to click the 'Yes' button automatically by scriptEngine. I know from others topics here in forum, that some dialogs can be auto-answered using system.prompt_answers. And I also get the messagekey of this dialog: Key: "<< No Key>>" Message: "Do you want to upgrade the storage format for this project? - If you click 'Yes',... i have tried using the system.prompt_answers command below, but the dialog was not auto-answered. system.prompt_answers["<<No Key>>"] = PromptResult.Yes Does someone know how to auto-answer the dialog using system.prompt_answers command with messagekey"<< No key>>"? or any suggestions to solve this issue, Thanks!
Last updated: 2024-01-26
Post by kevin123 on (no subject)
CODESYS Forge
talk
(Post)
I am trying to do "update device" in a project which was saved in a different version of CODESYS using ScriptEngine, a dialog with 'Yes' and 'No' button popped up showing that "Do you want to upgrade the storage format for this project? -if you click 'Yes', storage format will be upgraded... -if you click 'No', storage format will not be changed..." I have to click the 'Yes' button automatically by scriptEngine. I know from others topics here in forum, that some dialogs can be auto-answered using system.prompt_answers. And I also get the messagekey of this dialog: Key: "<< No Key>>" Message: "Do you want to upgrade the storage format for this project? - If you click 'Yes',... i have tried using the system.prompt_answers command below, but the dialog was not auto-answered. system.prompt_answers["<<No Key>>"] = PromptResult.Yes Does someone know how to auto-answer the dialog using system.prompt_answers command with messagekey"<< No key>>"? or any suggestions to solve this issue, Thanks!
Last updated: 2024-01-26
Post by wmoon on Licensing info not available.
CODESYS Forge
talk
(Post)
That command can't excute on my device. I installed CODESYS into Hilscher's product using container Here is the Docker file what I used. I'm not sure if this docker file have a problem. If it have a problem, please let me know how to download the files into my device using ftp server. FROM arm64v8/debian:11.6 RUN apt-get update RUN apt-get install -y wget sudo unzip libusb-1.0-0-dev procps ENV CDS_VERSION "4.10.0.0" ENV EDGE_VERSION "4.10.0.0" ENV URL "https://store-archive.codesys.com/ftp_download/3S/LinuxARM64/2302000039/$CDS_VERSION/CODESYS%20Control%20for%20Linux%20ARM64%20SL%20$CDS_VERSION.package" ENV EDGE_URL "https://store-archive.codesys.com/ftp_download/3S/EdgeGatewayLinux/000120/$EDGE_VERSION/CODESYS%20Edge%20Gateway%20for%20Linux%20$EDGE_VERSION.package" RUN wget --output-document=/tmp/codesys.package $URL && \ unzip -p /tmp/codesys.package 'codemeter.deb' > /tmp/codemeter.deb && dpkg -i /tmp/codemeter.deb && \ unzip -p /tmp/codesys.package 'codesyscontrol.deb' > /tmp/codesys.deb && dpkg -i /tmp/codesys.deb RUN wget --output-document=/tmp/edge.package $EDGE_URL && \ unzip -p /tmp/edge.package '*arm64.deb' > /tmp/edge.deb && dpkg -i /tmp/edge.deb EXPOSE 11740 1217 11743 ENTRYPOINT ["/bin/sh", "-c" , "/etc/init.d/codesyscontrol start && /etc/init.d/codesysedge start && tail -f /dev/null"]
Last updated: 2024-03-20
Post by fontrap on cmDongle Raspberry Pi issue
CODESYS Forge
talk
(Post)
Hello mates, I'm working with CODESYS V3.5 SP20 on a Raspberry Pi and I use "Raspberry Pi MC SL" as device on the project. I've installed the Control Standard L (multicore) license on a Wibu System usb-Dongle (cmStick/4.50) that already had another license from another vendor. I follow the online activation procedure from CODESYS documentation. Raspberry Pi has already CodeMeter installed for the other license. When I plugin the dongle on Raspberry and start the Runtime from Raspberry Pi Update in CODESYS I receive the message that I'm on Demo mode because the license is missing. I double checked that the license is activated in the dongle, through the WebAdmin of CodeMeter and the second license runs properly without any issue. I have already try to change the dongle from HID to MSD device and backward but the the Runtime cannot recognize the Dongle. I have also try to stop and start the Runtime through CODESYS without success. Is there anything else I can do to fix this issue?
Last updated: 2024-04-22
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.