Post by stewnguth on New License not working. CODESYS Forge talk (Post)
Hey there, I am pretty new to the codesys space, but I got a codesys control basic M license for my raspberry pi that isntalled with no problem yesterday. Today, I went to install the visualization M locense as well because I went over the variable limit and am getting a "servernotfound" error in codesys when attempting to activate. I also tried to follow the advice in some other threads and install using a license request file on the web interface but am getting a message saying "An internal error occured" when attempting to install the license. Can anyone help me get this up and running? Thanks for your time.
Last updated: 2024-05-23

Post by nathant on Running webvisu with Codesys Control Win V3 in Simulation Mode CODESYS Forge talk (Post)
Hello - I was wondering if I can run a webvisu in Codesys V3.5 SP 18 when using the Control Win V3 soft PLC. I don't see anything saying I can't do this, but I haven't been able to access the webvisu using conventional methods. Thanks.
Last updated: 2023-11-28

Post by nathant on Running webvisu with Codesys Control Win V3 in Simulation Mode CODESYS Forge talk (Post)
Hello - I was wondering if I can run a webvisu in Codesys V3.5 SP 18 when using the Control Win V3 soft PLC. I don't see anything saying I can't do this, but I haven't been able to access the webvisu using conventional methods. Thanks.
Last updated: 2023-11-28

Post by damian177 on Codesys Control for Linux SL CODESYS Forge talk (Post)
Hi, For many years my application has been running on Raspberry Pi. Now I have ported the application to a PC running with Debian OS with Codesys Control for Linux SL. Most of things works. But some is wrong with serial ports. Firstly , I wonder why /etc/CODESYSControl.cfg in Debian is empty ?
Last updated: 2024-09-08

Post by pernockham on Preferred way of managing Ip-adress/es for linux (debian) host? CODESYS Forge talk (Post)
I have a debian linux host running Control SL. I tried to manage IP-addresses through codesys/Control SL but that was not successful. What works though is manually editing the network-interfaces config file. /etc/network/interfaces. Is there a way to set this up so that IP-addresses can be managed from within codesys instead? Thanks! / Per
Last updated: 2025-01-22

Post by smic on Virtual Control SL Profinet connection CODESYS Forge talk (Post)
Hi. I'm trying to connect Profinet device with Virtual Control for Linux SL. After adding devices, I couldn't find actual device by Scan Device? Do I missed something? VPLC container on Docker IP: 172.17.0.4 Subnet: 255.255.0.0 Gateway: 172.17.0.1 Profinet device: AL1100 io-link master (default setting) IP: 0.0.0.0 Subnet:0.0.0.0 Gateway:0.0.0.0
Last updated: 2025-02-28

Post by rajatdas2005 on Codesys Virtual control SL CODESYS Forge talk (Post)
Thanks once again. Right now the codesys virtual control sl docker is using the host ip itself not the docker ip. so the local host edge gateway was able to search the virtual plc. so you are telling me instead of local host edge gateway I should use the edge gateway docker version?
Last updated: 2025-08-08

Post by preimesbergert on Codesys Control for Raspberry Pi 4.10.0.0 - Raspberry Pi OS > 2023-12-05 CODESYS Forge talk (Post)
Same issue here: Raspberry Pi 4 Model B HW 1.5 Regardless of the image (tried 32bit / 64bit version from Raspberry Pi Imager- all the "standard version") and with all tested Codesys Control versions (4.2.0, 4.8.0, 4.10.0) and regardless if single core / multicore / 64 bit variant.
Last updated: 2023-12-21

Post by annd on Migration von "CODESYS Control for PFC200 SL" zu WAGO FW26 "CODESYS V3.5.19.2" CODESYS Forge talk (Post)
@pflot59: Thanks, I know this guide but there a slight differences in migrating from eCockpit or from Codesys SL. It is still fine as I wrote above. BR annD
Last updated: 2023-11-23

Post by winki on Modbus TCP & RTU with Control for Linux SL CODESYS Forge talk (Post)
Maybe I don't know. **Maybe if someone know it can help me. ** I will try Constrol SL runtime in the Host. I will try to but only Nic without IP
Last updated: 2024-10-23

Post by jonasz on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
So here's how: I manually installed the following packages: codemeter-lite_8.30.6885.501_amd64.deb codesyslicenseserver_licenseserver_4.18.0.0_all.deb codesyswbmbase_wbmbase_4.18.0.0_all.deb codesyswbmlicensing_wbmlicensing_4.18.0.0_all.deb Of course, the license server appeared immediately. Trying to install it again using Install in the Deploy tab, the same error appears. Of course, the information that such a server is already installed is also there. Configuring PLC, S_PLC, EDGE, and SAFE_TIMER_PROVIDER went smoothly, and basically everything works. I wrote a simple program for S_PLC. I'm loading the programs into PLC and S_PLC. When loading the program into S_PLC, a message appears stating that there is no connection to the S_PLC controller. Timeout error. Restart the controller, attempt to load, and see the above. After changing the cycle time for S_PLC to 50ms, the problem no longer occurs. My question, besides the difficulty of installation for a new user, is what causes the cycle time for S_PLC to be so long, and how can I fix it?
Last updated: 2025-11-14

Post by superjojo2002 on Licensing info not available. CODESYS Forge talk (Post)
I checked it using the very same docker container version like colleague moon and the command returned root@nt0001c02c5533:/# cmu -x cmu - CodeMeter Universal Support Tool. Version 7.60c of 2023-Aug-09 (Build 5625) for Linux/ARMHF 64-Bit Copyright (C) 2007-2023 by WIBU-SYSTEMS AG. All rights reserved. Result: 0 CmContainer(s) listed. (CodeMeter not running) Please consider that we intend to license a codesys ARM64 SL in a docker container.
Last updated: 2024-03-20

Post by eschwellinger on License problem gateway CODESYS Forge talk (Post)
I just try to help. Anyway it is a big difference if a Store SL runtime or an oem plc and licence is used. These licenses need to be activated on plc side - so you have dependencies to the version (CODESYS and Runtime Version) Did you ever ask Epis out for this situation? They should know which license fit to their device. Even they should know if the device is capable for Softmotion and see the requiremnts in the CODESYS store: Runtime 4.9.0.0 - how should this work with Epis 3.5.16.x? Anyway refund is not a problem.
Last updated: 2024-04-26

Post by dhumphries on How to determine code size CODESYS Forge talk (Post)
I'm trying to determine which Codesys Control license I need, the Control Standard S has all the features I think I'll need, but the code size is limited to 3mb, I created a simple program with only 1 line of ladder logic and a simple visualization with a button and an indicator. When I generate code I get some messages, one indicates that the total allocated memory size for code and data is 2.1mb. Is this metric the correct size of the code? I question the size because it exceeds the allowable code size for the Basic S and Basic M licenses and consumes 2/3 of the available memory for the Basic L or Standard S license. What tool can I use to estimate the size of code as it relates to the runtime license limit?
Last updated: 2024-04-05

Post by timl on Application has invalid license metrics CODESYS Forge talk (Post)
Hallo, ich habe eine Control for Linux SL auf der ich einen TCP Modbus Master anlege, mit dem ich einen Slave auslesen möchte. Das Anlegen funktioniert soweit alles, sobald ich beim ModbusTCPSlaveE/A-Abbild in den Channel eine Variable einfüge, damit ich den Channel auslesen kann, kommt es beim übertragen auf die SPS zu einem Ausnahmefehler. Im Anhang noch eine Bilder der Fehlermeldung und der installierten Lizenzen. CODESYS Version ist V3.5 SP19 Patch 4 Meinem Verständnis nach ist die Modbus Lizenz mit in der Control Standard L inbegriffen und auch in der Lizensierten Softwaremetrik sehe ich keine überschreitung meiner Lizenzbegrenzungen. Daher verstehe ich nicht wieso ich diesen Fehler bekomme und eine auslesung via Modbus nicht möglich ist. Gruß Tim
Last updated: 2024-05-08

Post by mavitia on Application based license problem - Modbus TCP CODESYS Forge talk (Post)
raspberry pi is running ubuntu, so it has the codesys control for linux arm 64 bit, IDE is 3.5.19, both were installed last week from the latest versions online, im currently out of the PC but will upload some evidence ASAP
Last updated: 2023-12-18

Post by mavitia on Issue with TargetVisu on Codesys Control Win CODESYS Forge talk (Post)
anyone else running into the same issue: perform a repair install on the runtime, that should fix it without affecting license.
Last updated: 2024-02-02

Post by valenting on Problem with Licenced Software Metrics CODESYS Forge talk (Post)
Update: it seems that the license is detected by CODESYS on my computer but not detected by the runtime on my device. I'm using Codesys control for raspberry pi in the latest version 4.11.0.0 Is there something to do to correct this ?
Last updated: 2024-04-29

Post by eschwellinger on License Reset Request – CODESYS Control Win V3 Standard L CODESYS Forge talk (Post)
Please write these kind of request to 'my question' in the CODESYS Store. please do not use ticket and softcontainer numbers here.
Last updated: 2025-10-23

Post by jonasz on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
Hello, Basically, everything is clear to me. There's still the issue of a TimeProvider for an external device. This may be a stupid question, but I can't find this package. And of course, the question is, can the RPi machine be an external provider? Has anyone tested such a solution?
Last updated: 2025-11-18

Post by eschwellinger on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
As I see from your logs I think the Timeprovider is not accurate enough in your case. Things to check - at the moment you run it on the same device? (for tesing purpose ok) I would set 127.0.0.0 as IP and set it not really to Core 0 ( many other stuff is there)
Last updated: 2025-11-20

no synchronization via field bus(Raspberry Sl softmotion) CODESYS Forge talk (Thread)
no synchronization via field bus(Raspberry Sl softmotion)
Last updated: 2018-05-29

Raspberry Pi 4.12.0.0 SL also stops after 15s CODESYS Forge talk (Thread)
Raspberry Pi 4.12.0.0 SL also stops after 15s
Last updated: 2024-07-06

OPC-UA Client connection, Linux SL /Raspberry Pi CODESYS Forge talk (Thread)
OPC-UA Client connection, Linux SL /Raspberry Pi
Last updated: 2024-08-21

OpC UA server on Raspberry Pi 64 SL runtime CODESYS Forge talk (Thread)
OpC UA server on Raspberry Pi 64 SL runtime
Last updated: 2024-12-12