Post by mp9876 on Device User Logon
CODESYS Forge
talk
(Post)
Following up on the invalid user authentication on the target Not 100% sure what the problem was but following my post I managed to create an administrator level user. Then my next issue was that I could not connect to the device. I might have flipped the device from a 64 bit version to a 32 bit version so I did UPDATE DEVICE back to the 64 bit version; still could not connect somehow. Then I did two things at the same time that fixed my problem: Wiped the Codesys Control Win 64 bit version and installed the 32 bit version Installed latest Codesys Control Win V3.5 SP20 (released today) I wish I knew which one of these actions fixed the problem but at least the problem is solved. Hoping this post may help someone one day
Last updated: 2024-03-19
Post by wiresplus on How to Connect / Go Online without re-downloading the project
CODESYS Forge
talk
(Post)
Hello, I have a PLC in a remote location. I can connect to it, but when I use a different PC, it asks me to re-download to the PLC - which will a) interrupt production and b) cause version issues. Codesys being open-source, if someone else has made changes, I need to be able to connect, upload the current project, compare it with mine and then decide what next. Every time I connect, it says Warning: An application 'Application' is currently in RUN mode on the PLC. As there is no matching compile information, this existing application needs to be replaced. Click 'Yes' to download the latest code or 'No' to abort. What am I doing wrong?
Last updated: 2024-04-13
Post by imdatatas on Codesys IDE initialization error from a new Sandbox image
CODESYS Forge
talk
(Post)
Hello everyone, I created a new sandbox image on the D drive with Codesys Installer. However, when I launch the IDE from this image, it gives the error shown in the attached image. -- Codesys V3.5 SP19 Patch7. -- The installer is the latest (2.5.0). -- All packages in the installer were updated to the latest version as of today when creating the sandbox. -- The originally installed IDE on the C drive does not give this error when launched. -- I last upgraded it to Softmotion 4.20.1.0 through the installer. Has anyone encountered the same or a similar issue? Will this issue be fixed in the next update? Best regards, Imdat
Last updated: 2025-12-05
Post by pernockham on How to manage soft container licenses for (remote) multi units?
CODESYS Forge
talk
(Post)
Using Codesys runtime for Linux and thinking of the process of preparing multiple such systems for my customer. I don't necessarily have physical access to these units, they can be (very) remote. The idea so far is to use an image to install the Linux OS and codesys runtime. Application updates can be done by distribution of the PlcLogic/Application/application.app and application.crc files. But whats the most practical way of managing the license for these units? Do each controller need to be physically connected to a License Manager instance or can licenses be distributed by means of a license file for each unit? I believe that the license should be stored in soft containers for each unit. Help and insights appreciated! Per
Last updated: 2025-04-04
Post by starmaxou on How to download dependencies packages for CODESYS Control for Raspberry Pi SL ?
CODESYS Forge
talk
(Post)
Hi everyone, I'm trying to install the CODESYS Control for Raspberry Pi SL package. The computer with CODESYS software is offline for security reasons. So, I downloaded the package on another computer and installed it manually. But this package has dependencies packages: CODESYS.Control SL Extension Package, V4.0.0.0 CODESYS.Control SL Deploy Tool, V4.10.0.0 As I said, the computer with CODESYS is offline. I cannot use the package installer to search for these packages. I did not find them in Codesys Store with another computer. Do you know where to find and download them? Thank you in advance for your help!
Last updated: 2024-05-30
Post by scoob on ModbusFB - Slow Response Time
CODESYS Forge
talk
(Post)
Hello, I have been trying to use the ModbusFB functions so I can put some code into libraries, but it seems to be very slow for me. I have a Modbus device with 100ms registers. I previously setup 10 channels in the 'traditional' Modbus Slave with channels and mappings - and set a cyclic trigger at 100ms - this worked fine. I then tried the ModbusFB example, and setup reading the same 10 blocks of modbus addresses, copying the example and putting all of the requests into an array and triggering the requests sequentially. I timed how long the requests are taking to get round to each one, and it is around 1s 450ms. How do I speed this up to match the cyclic time? IF NOT(init) THEN init := TRUE; // Set the required IP address: ipAddress[0] := 192; ipAddress[1] := 168; ipAddress[2] := 1; ipAddress[3] := 10; // Pass the required IP address to the clinet FB: client_NetworkSwitch.aIPaddr := ipAddress; client_NetworkSwitch.udiLogOptions := (ModbusFB.LoggingOptions.ClientConnectDisconnect OR ModbusFB.LoggingOptions.ClientReceivedValidReplies); // Try to connect the client client_NetworkSwitch(xConnect:=TRUE); // Configure all the channels to read connecting them to the client: portStatus_Request(rClient := client_NetworkSwitch, uiStartItem := 4096, uiQuantity := 32, pData := ADR(portStatus), udiReplyTimeout := udiReplyTimeout); portSpeed_Request(rClient := client_NetworkSwitch, uiStartItem := 4352, uiQuantity := 32, pData := ADR(portSpeed)); flowControl_Request(rClient := client_NetworkSwitch, uiStartItem := 4608, uiQuantity := 32, pData := ADR(flowControl)); linkUpCounter_Request(rClient := client_NetworkSwitch, uiStartItem := 5888, uiQuantity := 32, pData := ADR(linkUpCounter)); txPacketCounter1_Request(rClient := client_NetworkSwitch, uiStartItem := 8192, uiQuantity := 100, pData := ADR(txPacketCounter1)); txPacketCounter2_Request(rClient := client_NetworkSwitch, uiStartItem := 8292, uiQuantity := 28, pData := ADR(txPacketCounter2)); rxPacketCounter1_Request(rClient := client_NetworkSwitch, uiStartItem := 8448, uiQuantity := 100, pData := ADR(rxPacketCounter1)); rxPacketCounter2_Request(rClient := client_NetworkSwitch, uiStartItem := 8548, uiQuantity := 28, pData := ADR(rxPacketCounter2)); txErrors_Request(rClient := client_NetworkSwitch, uiStartItem := 8704, uiQuantity := 64, pData := ADR(txErrors)); rxErrors_Request(rClient := client_NetworkSwitch, uiStartItem := 8960, uiQuantity := 64, pData := ADR(rxErrors)); // Trigger all client requests initially FOR clientRequestsCnt := 0 TO (SIZEOF(clientRequests)/SIZEOF(clientRequests[0]))-1 DO pClientRequest := clientRequests[clientRequestsCnt]; pClientRequest^.xExecute := TRUE; END_FOR // Prepare sequential trigger / control of client requests. clientRequestsCnt := 0; pClientRequest := clientRequests[clientRequestsCnt]; END_IF // Call the client to do request processing: client_NetworkSwitch(); // Now we trigger client request sequentially ... IF NOT pClientRequest^.xExecute AND NOT pClientRequest^.xDone AND run AND client_NetworkSwitch.xConnected THEN pClientRequest^.xExecute := TRUE; END_IF // .. and check result/error IF pClientRequest^.xExecute AND run AND client_NetworkSwitch.xConnected THEN IF pClientRequest^.xDone THEN // Prepare next trigger of client request (a rising edge of xExecute) pClientRequest^.xExecute := FALSE; IF clientRequestsCnt < SIZEOF(clientRequests)/SIZEOF(clientRequests[0])-1 THEN // next client request clientRequestsCnt := clientRequestsCnt + 1; ELSE clientRequestsIterationCounter := clientRequestsIterationCounter + 1; clientRequestsCnt := 0; END_IF pClientRequest := clientRequests[clientRequestsCnt]; END_IF END_IF I did try a semi-coded way using the IoDrvModbusTCP library, and setting the slave com settings, then 10 commands and 10 requests, then using a TP on xDone as a pause, before triggering another request - this is time the delay is around 120ms - so the device is fine with the speed, just something I am doing wrong in the ModbusFB method I am sure.
Last updated: 2024-04-26
Post by rajatdas2005 on Codesys Virtual control SL
CODESYS Forge
talk
(Post)
Dear All, This is regarding Codesys Virtual control SL demo version. I am facing one issue. First I will describe the steps what I have followed till now. 1. In a PC I have Windows OS. Here Codesys IDE is installed, and also using the installer option of IDE I have also installed Codesys Virtual control SL. 2. A edge-gateway is also running in the same windows PC as local host. 3. Next I have a seperate PC with Ubuntu OS with docker installed. This machine is in the same network. 4. Now I have created a project in Windows machine using device "Codesys Virtual control SL". 5. In the Ubuntu machine I am running the Codesys Virtual control SL as docker and it is using the ubuntu machine network only. 6. Next using the localhost edge-gateway when I am searching the virtual control SL docker it is able to detect it. (screenshot attached) 7. But after creating the creadentials it is telling No Device is responding. 8. I have also checked the wireshark logs and able to see that in destination port 11740 data is coming. 9. From windows PC telnet ip 11740 is also working. 10. Ping is also working ===========================================LOGS ========================= sudo ss -tlnp | grep -E "(443|1217|4840|8080|11740)" LISTEN 0 10 10.135.114.142:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=21)) LISTEN 0 10 172.18.0.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=24)) LISTEN 0 10 172.17.0.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=23)) LISTEN 0 10 127.0.0.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=26)) LISTEN 0 10 192.168.122.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=22)) LISTEN 0 5 0.0.0.0:11740 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=20)) LISTEN 0 128 0.0.0.0:8080 0.0.0.0: users:(("python3",pid=1280,fd=4)) LISTEN 0 10 172.19.0.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=25))
Last updated: 2025-08-06
Post by vformanek on No source code available for profinet library
CODESYS Forge
talk
(Post)
I have tried downgrading and it seems fine now. I am now on version 4.3.0.0 for the library. Mainly the PN controller caused the issue for me. Funny weird is that even the PN controller versions 4.3.1.0 and 4.3.0.0 cause the error. Version 4.2.0.0 works fine.
Last updated: 2023-08-23
Post by martinlithlith on CODESYS Control for Raspberry Pi SL on Raspberry Pi 4b
CODESYS Forge
talk
(Post)
hi! a quick question - is it possible to run CODESYS Control for Raspberry Pi SL license on a raspberry pi 4b? i know it says all models in the data sheet, but im not sure it the data sheet has been updated seince the MC-processors for pi. best, Martin
Last updated: 2023-09-04
Post by martinlithlith on Device User Logon and No device is responding.. Pi4b codesys 3.5 SP19 2 + (64-bit)
CODESYS Forge
talk
(Post)
Hi, Thank you for your reply! What should be the version 4.9.0.0? I have a user named pi on the pi, thats what iΒ΄m using as credientials to be able to for example update/install runtime. Or do i need another user? once agin, thank for the reply! Martin
Last updated: 2023-09-11
Post by eschwellinger on Correct CAN Driver for EL6751
CODESYS Forge
talk
(Post)
Hi, for Control Win : add CmpEL6751CanDrv in the c:\ProgramData\CODESYS\CODESYSControlWinV3x64\E1FA7ABE\CODESYSControl.cfg [ComponentManager] Component.1=CmpTargetVisuStub Component.2=CmpWebServer Component.3=CmpWebServerHandlerV3 Component.4=SysCpuMultiCore Component.5=SysReadWriteLock Component.6=SysCpuBreakpoints Component.7=SysPipeWindows Component.8=CmpEL6751CanDrv for Linux SL or Pi or any ARM device - I think it is already static loaded as component - see plclogger on startup
Last updated: 2023-09-20
Post by callumo1 on Check For Open Dialogs On Client
CODESYS Forge
talk
(Post)
Is it possible to make a function that checks to see if there are any open dialogs on a given clients. I think VisuDialogs.VisuDlgUtil_IsDialogOpen does this for a given dialog name, but is it possible to do this for any dialog. Appretiate any help Cheers Callum
Last updated: 2023-09-25
Post by callumo1 on Check For Open Dialogs On Client
CODESYS Forge
talk
(Post)
Thanks for the reply. I want to be able to check if any dialogs are open of any name. I already have a function similar to what you have send but I don't want to have to run it for all the different dialog names. Thanks
Last updated: 2023-09-26
Post by chirag on About byte swap and convert into 16 bits
CODESYS Forge
talk
(Post)
Hello, I have %QB0 8 high bits and %QB1 8 low bits . How can i swap bits %QB0 and %QB1 for requirment positions in a 16-bit value ? after that i need %QB0 and %QB1 in to 16bits . For that, i need help. Please see attached pictures for your reference. Thanks in advance.
Last updated: 2023-12-04
Post by rschwager on GVL to SHMem
CODESYS Forge
talk
(Post)
Hallo! Have some any idea to transfer whole GVL to Shared Memory? I also shared REATIN memory to shraed meory for making a Retain Backup System without USP in Linux on a FRAM. For an other Application we want to shared the whole GVL off obne part (e.g. GVL_Test). How cvan I get easy the Size and the Address for meory copy?
Last updated: 2024-07-09
Post by mrrobot on No source code available for this object
CODESYS Forge
talk
(Post)
Hello, I have this strange error while I am adding an axis to my slave: "No source code available for this object because it is in the compiled library 'sm3_drive_etc_ds402_cyclic' ..... I looked on google/chatgpt but i cannot find a solution for this issue Any help is welcome ! Thanks in advance Mrrobot
Last updated: 2024-07-15
Post by mrrobot on No source code available for this object
CODESYS Forge
talk
(Post)
Hello, I have this strange error while I am adding an axis to my slave: "No source code available for this object because it is in the compiled library 'sm3_drive_etc_ds402_cyclic' ..... I looked on google/chatgpt but i cannot find a solution for this issue Any help is welcome ! Thanks in advance Mrrobot
Last updated: 2024-07-15
Post by damian177 on Codesys Control for Linux SL
CODESYS Forge
talk
(Post)
Hi, For many years my application has been running on Raspberry Pi. Now I have ported the application to a PC running with Debian OS with Codesys Control for Linux SL. Most of things works. But some is wrong with serial ports. Firstly , I wonder why /etc/CODESYSControl.cfg in Debian is empty ?
Last updated: 2024-09-08
Post by cakar16 on Looking for BL20-PG-EN-V3, V3.5.11.20 Device Driver
CODESYS Forge
talk
(Post)
Hi Everyone, I am Karnadi I am looking for device driver for the following Turk devices and version: - BL20-PG-EN-V3, V3.5.11.20 (Turk) - BL20-2RFID-S, V1.1.3.0 (Turk) - BL20-1RS485/422, V1.1.3.0 (Turk) - BL20-4DO-24VDC-0.5A-P, V1.1.3.0 (Turk) - Ethernet, 3.5.11.20 (Turk) Appreciate if anyone of you can share the device driver (config package) above Thanks and Regards Karnadi
Last updated: 2024-10-04
Post by somlioy on CODESYS Control for PFC100 SL Firmware upgrade
CODESYS Forge
talk
(Post)
Hi We delivered a system with a PFC100 using the CODESYS Control for PFC100 SL runtime a few years back. The system has once been decommissioned and are now to be commissioned again. Back then, there were only single licenses for the runtime. Can I now upgrade the firmware and runtime without purchasing a new license?
Last updated: 2025-02-27
Post by alawwirbilal on Codesys for raspberry pi 5 not working exactly
CODESYS Forge
talk
(Post)
Hello, I have installed the runtime system on my raspberry pi 5 and when I scan for the devices it sees. But when I try to log in to the device it always ask me for a password and no matter what I give it says this is a wrong password. anyone could help?
Last updated: 2025-03-06
Post by pafarrell on EtherCAT quick start for advanced programmers
CODESYS Forge
talk
(Post)
It would be great if there was a thread that had some quick-start links for basic how-to. But one that advanced programmers can jump into. I found this video playlist by SoftMotion-Black, which was very, very helpful: https://www.youtube.com/playlist?list=PLkc8m2OD0r9xJyfTiCBb1vuU_d2yBhjZ_ This person has some other great vids like creating your own custom library, which is awesome for OEMS.
Last updated: 2025-05-14
Post by morecoffee on Control for Raspberry Pi 4.17
CODESYS Forge
talk
(Post)
I am currently having the issue that Codesyscontrol only runs for 10 seconds on my Raspberry Pi 4. I believe the problem is because the MAC address range is of the Raspberry is 88:A2:9E:XX:XX:XX. When will Codesys Control For Raspberry Pi 4.17.0.0 be released to fix this issue?
Last updated: 2025-08-22
Post by eschwellinger on TargetVisu option missing in IDE
CODESYS Forge
talk
(Post)
It is not needed to add Targetvisu connector - for using the TargetVisu for Linux. The reason is - TargetVisu for Linux is basically a remote TargetVisu which could connect to any CODESYS plc not only the loacal one - therefore only a Webvisu connector is needed to have it work. & it seems a bug with this anoying update proposal.
Last updated: 2025-08-23
Post by wagokurt on CODESYS Visualization M License Fails to activate on Linux SL
CODESYS Forge
talk
(Post)
The fix for this is when you install the control SL license, there is a checkbox for the Visu S license option. You must click this option. The Visu M is technically an upgrade to the Visu S, if this is license is not installed them the Visu M will fail as shown above. Thanks JoJo for the solution!
Last updated: 2025-08-25