Post by totorovic on CSVReaderInit returns error : INVALID_HANDLE
CODESYS Forge
talk
(Post)
Actually no solution. We are waiting Codesys reply. Latest version of library : licence error message Version 1.0.0.5 : INVALID_HANDLE error message
Last updated: 2023-08-21
Post by sven01 on Documentation / Usage Help For Scripting Engine Libraries
CODESYS Forge
talk
(Post)
Hi, I am still not able to figure out how to use the the classes and their functions. 😔 Let's say I would like to use the function "importfile()" from the class "ScriptTextListObject.ScriptTextListMarker". I would be grateful for an additional example. Thanks! 😊
Last updated: 2023-08-21
Post by vincentger on Raspberry Pi Control SL MC - Restoring License not working anymore!
CODESYS Forge
talk
(Post)
Running into the same problem restoring a Runtime 4.4.0.0 device on a now 4.8.0.0 device.
Last updated: 2023-08-21
Post by kunz on Profinet Device keeps abort connection with AR alarm.ind(err)
CODESYS Forge
talk
(Post)
Can somebody explain what the error Connection aborted: AR alarm.ind(err) exactly mean? I have the same Problem and dont know how to solve the issue
Last updated: 2023-08-21
Profinet Device keeps abort connection with AR alarm.ind(err)
CODESYS Forge
talk
(Thread)
Profinet Device keeps abort connection with AR alarm.ind(err)
Last updated: 2023-08-21
After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working
CODESYS Forge
talk
(Thread)
After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working
Last updated: 2023-08-22
Post by rossanoparis on After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working
CODESYS Forge
talk
(Post)
For those who will step on this thread. Everything is fine, I had only to increase by 1 my place holders number. For sure the system is occupying the number 1 without being declared ... Below the modification I made to get my code working. [SysFile] PlaceholderFilePath.2=/home/pi/hpca/bin, $hpcabin$ PlaceholderFilePath.3=/home/pi/hpca/cfg, $hpcacfg$ PlaceholderFilePath.4=/home/pi/hpca/logs, $hpcalogs$ PlaceholderFilePath.5=/home/pi/hpca/resources, $hpcares$
Last updated: 2023-08-22
Post by t-probst on Strong Private Key Protection for Encryption Certificates
CODESYS Forge
talk
(Post)
Hello, We are trying to implement an automated method of adding of a certificate and private key to the Windows certificate store for encrypting CODESYS projects. We want to do this so that users do not have to deal with details of certificates at all and to prevent user error. We are keen on enforcing strong private key protection since it ensures that a password is required for the certificate to be used to decrypt a CODESYS project. When we add a certificate to the certificate store and enable strong key protection using the Microsoft Management Console Certificates snap-in, it works as expected. However, through this method the user may mistakenly not enable strong private key protection. For the certificates we create programmatically (using Microsoft’s Cryptography Next Generation API in .Net 7) bag attributes are added to the certificate and key by the API. These bag attributes are as follows: Bag Attributes localKeyID: 01 00 00 00 subject=C = xx, ST = xxx, O = xxx, OU = xxx, CN = xxx issuer=C = xx, ST = xxx, L = xxx, O = xxx, OU = xxx, CN = xxx -----BEGIN CERTIFICATE----- [encoded certificate] -----END CERTIFICATE----- After using this certificate with bag attributes to encrypt a CODESYS project, it can’t be decrypted, showing this error: "The specified project could not be loaded. Possible reasons might be: - The project file is corrupted or invalid - The project has been saved with a newer version of the programming system. If this is the case, you can open the project in the corresponding version. Choose "Save as..." with the appropriate storage version, and retry again. - You may not have the necessary permissions to lad the project" We know that the bag attributes are causing the issue because if we manually edit the certificate file to remove them before using the certificate to encrypt a project, the project can be decrypted as expected. However, we are unable to automatically enforce strong key protection using this method. Here is a link to a StackOverFlow question that we have posted recently for this issue: https://stackoverflow.com/questions/76922355/enforcing-strong-private-key-protection-for-x509certificate2-objects-in-net-mod Any help is greatly appreciated.
Last updated: 2023-08-22
Strong Private Key Protection for Encryption Certificates
CODESYS Forge
talk
(Thread)
Strong Private Key Protection for Encryption Certificates
Last updated: 2023-08-22
Post by paulpotat on Project size increasing continuously
CODESYS Forge
talk
(Post)
I still have the same problem with Codesys 3.5 SP18. Initially, my project is ~5 Mo. I work on it for like 3-4 days and it goes up to ~10Mo. If I make an export of the project and import it in a new empty project, it goes back to approximately 5 Mo. Why is it doing this ?
Last updated: 2023-08-23
Post by vformanek on No source code available for profinet library
CODESYS Forge
talk
(Post)
Hello, I have been using CODESYS for a while and after updating to version 3.5.18.50 the code randomly stops with this fault. Why is that ? I have tried to locate the fault in the Call Stack but I dont know what to do now... I have updated the projects properly for the version I am using. This fault started happening after like 14 days of using the new version of CODESYS.
Last updated: 2023-08-23
Post by hugob on Start Control Win Softmotion Runtime
CODESYS Forge
talk
(Post)
Last updated: 2023-08-23
Start Control Win Softmotion Runtime
CODESYS Forge
talk
(Thread)
Start Control Win Softmotion Runtime
Last updated: 2023-08-23
Post by bbm1995 on Security Screen - Custom Certificates for OPC UA Server?
CODESYS Forge
talk
(Post)
Hi everyone, is it possible to use selfsigned/created certificates (eg. with X - Certificate and Key Management) as a OPC UA Server certificate in the Security Screen? As far as I know I can only upload client certificates to the PLC and move it to "Trusted", "Untrusted" and "Quarantined". Same question is on sps-forum.de
Last updated: 2023-08-23
Post by kreisfilho on Same program to more than one PLC
CODESYS Forge
talk
(Post)
Hi, How can I assign a monitor (non touch) connected to a Raspberry pi (via HDMI) as visualization output?
Last updated: 2023-08-23
Post by vformanek on No source code available for profinet library
CODESYS Forge
talk
(Post)
I have tried downgrading and it seems fine now. I am now on version 4.3.0.0 for the library. Mainly the PN controller caused the issue for me. Funny weird is that even the PN controller versions 4.3.1.0 and 4.3.0.0 cause the error. Version 4.2.0.0 works fine.
Last updated: 2023-08-23
No source code available for profinet library
CODESYS Forge
talk
(Thread)
No source code available for profinet library
Last updated: 2023-08-23
Post by fless on No source code available for profinet library
CODESYS Forge
talk
(Post)
looks like you are running in a bug in the newest version 4.4.0 of the profinet library or the new library triggers a bug in your code. did you update your profinet device too? you could try to downgrade to an older version of the library. via library manager - placeholders, double click Profinet 4.4.0 in the library column and choose an older version.
Last updated: 2023-08-23
Security Screen - Custom Certificates for OPC UA Server?
CODESYS Forge
talk
(Thread)
Security Screen - Custom Certificates for OPC UA Server?
Last updated: 2023-08-23
Post by kreisfilho on Stop raspberry from executing a plc program
CODESYS Forge
talk
(Post)
Hi guys, Can someone inform where in a raspberry pi are stored the codesys programs? I´ve been training the use of a RPI as PLC, which works pretty well, however while both the RPI and PC (running codesys) remain connected to the same network. The question is: how to run the codesys program downloaded to the RPI as a stand alone device (disconnected from the PC)? Thanks! Kreis
Last updated: 2023-08-23
Post by mozed on Connection to device closed
CODESYS Forge
talk
(Post)
Hello I am using an OpusA3 with version 3.5 SP17 Patch 3 as part of a project. I had no real problem before I encountered a problem that blocked me. The detection of the OpusA3 from Codesys is done correctly. The gateway is well configured and if I ping the gateway or the OpusA3 I receive the response correctly. The problem is that when I try to connect, the Opus screen freezes and a few moments later Codesys displays an error message ("connection to device closed"). I tried to change PC, to update the runtime, to change OpusA3 but the problem remains the same. I'm a little lost knowing that before it worked without problem. I went back to a previous version of the project (where it worked correctly) but the message still appears. Do you have any clues to solve the problem? Sincerely,
Last updated: 2023-08-23
Post by nativemode on V3.5 SP19 C-Code-Module nicht auffindbar
CODESYS Forge
talk
(Post)
Nachtrag: vom CODESYS-Support habe ich jetzt die Antwort erhalten, dass es nicht mehr möglich ist, C-Dateien direkt zu integrieren. Man kann aber immer noch mit vorkompilierten C-Bibliotheken arbeiten: https://content.helpme-codesys.com/de/CODESYS%20Development%20System/_cds_integrating_c_code.html
Last updated: 2023-08-23
Post by janderson on OPC UA Server limitations, large array crashes runtime
CODESYS Forge
talk
(Post)
What are the limitations of the OPC UA Server? I am trying to get data off my PLC that is acquired at high rates (~50k samples/s) so I am storing them in arrays and trying to get the arrays off the PLC. When I attempt to read a ~200k element array through OPC UA the server and runtime crashes (requiring tools -> update linux arm64 -> start runtime). Is there a better way to get highspeed data off? The ACDatalog library seems a bit irritating to use so I would prefer to go through OPC UA.
Last updated: 2023-08-23
Post by shooxplc on How to call the same program from library and get the vars updated.
CODESYS Forge
talk
(Post)
Hi, I am writing to you today because I would like to create a library that would contain a program with its various subprograms, in my example "PLC_PRG" with "a", "aa", "aaa". But once the library is created as shown below: I would like to be able to drag and drop my folder as many times as I want (let's say I manage the same system multiple times). Once the drag and drop is done, we can see the second folder with the variables renamed successfully. As shown below: But my variables in CAD_1 remain the same as for CAD, so it's PLC_PRG instead of PLC_PRG_1, for example. Is there a solution to automate this? I wouldn't want to have to rename all my variables manually, considering that in the program where I want to do this, the number of variables is substantial. Lucas.
Last updated: 2023-08-23
How to call the same program from library and get the vars updated.
CODESYS Forge
talk
(Thread)
How to call the same program from library and get the vars updated.