Search talk: key value

 
<< < 1 .. 4 5 6 7 8 .. 24 > >> (Page 6 of 24)

Post by davcide on button-keyboard CODESYS Forge talk (Post)
hi i have codesys v3.5, i should associate a button to a keyboard key with the ladder code. can you help me
Last updated: 2025-05-14

Post by timvh on Add licence CODESYS Forge talk (Post)
The Epis controller should support the CodeMeter driver to be able to access the license containers on the CODESYS Key.
Last updated: 2024-01-14

Post by eschwellinger on License problem gateway CODESYS Forge talk (Post)
as a workaround just plug your USB key to the CODESYS PC - and activate the ticket by the browser license.codesys.com
Last updated: 2024-03-27

Post by gepert on parker servo and position CODESYS Forge talk (Post)
Gentleman OMG, I made a huge mistake when i tried and moved shaft by hand i hold cover(as on photo) in my fingers. I was convinced that shaft has key but it there is not key. So when i turn cover it slide on shaft. When i take off cover and drive is in standstill, shaft does not move. So everything works perfectly
Last updated: 2024-08-07

Post by hyys12 on Energie price CODESYS Forge talk (Post)
I am definetly not an expert in this field, but it does seem like you need a propper API key in the URL. Right now you are using the token 'ANWB' in your URL, which the website returns an error, since this is not valid. Somehow you first need a propper API key. I hope that makes sense.
Last updated: 2024-12-06

Post by abuckie on Getting raw value as full resolution for ADS1115 CODESYS Forge talk (Post)
I just found this and I am getting a value larger than 16 bit, around 81000 something. I am reading a 5 volt value and I am using level shifters for the i2c bus. This is how I have the channel configured: ADS1115.usiAddress := 16#48; ADS1115.ChannelConfigs[0].Active := TRUE; ADS1115.ChannelConfigs[0].PGA := FSR_6144mV; ADS1115.ChannelConfigs[0].InputMux := Single_0; RawAnalogValue := ADS1115.Channels[0].Value; It looks like every value is a multiple of 3. Any idea where to look to fix this? I think i found what I want to change in UpdateChannels Channels[FChannelNo].Value := INT_TO_REAL(WORD_TO_INT(LValue) * GetFullScaleRange(ChannelConfigs[FChannelNo].PGA)) / 2048.0; I try to edit it but I can't, sorry if this is a basic question, I am new to CODESYS.
Last updated: 2025-05-22

Post by phoward131 on Numpad decimal value requires leading zero CODESYS Forge talk (Post)
I have noticed on the standard numpad dialog, if a user enters a purely decimal number (ie '.6'), the numpad will not accept the value but gives no indication. One must type a leading zero (ie '0.6') in order for it to work. Is there a way to correct this so that a user can just type the decimal value?
Last updated: 2024-04-30

Post by andreag0 on How to access to variable value through symbolic string name CODESYS Forge talk (Post)
Hello, anyone know how to get valiable value using a symbolic string name? For example: - send string to runtime using TCP/IP contains "GVL.TestINT" and get back the value. I need function that will translate the string to symbolic variable. Thank you. Andrea
Last updated: 2024-06-13

Post by mondinmr on Jitter problems on imx8 CODESYS Forge talk (Post)
SOLVED!!! In this imx8 max_cstate=1 in kernel boot parameters is not working! We found a workaround: #include <stdio.h> #include <fcntl.h> #include <unistd.h> #include <stdint.h> int main(void) { int fd; uint32_t value = 0; fd = open("/dev/cpu_dma_latency", O_WRONLY); if (fd < 0) { perror("Error opening /dev/cpu_dma_latency"); return 1; } if (write(fd, &value, sizeof(value)) != sizeof(value)) { perror("Error writing to /dev/cpu_dma_latency"); close(fd); return 1; } while (1) { pause(); } } This simple code launched before CODESYS do the same work! Now jitter is identical as measured by cyclictest!
Last updated: 2023-10-19

Post by hteich on IECStringUtils.FormatDateTime CODESYS Forge talk (Post)
Does that actually work, though? Where do you put in the actual Date_Time value??
Last updated: 2025-10-07

Post by rh-pk on v3.5 SP19 - Modbus TCP Devices - Channel Limit? CODESYS Forge talk (Post)
Hello Vincent, I don't have 75 channels but it works for me as described above without any problems. There is also a parameter MAX_MODBUS_CHANNELS in the library parameters for the IoDrvModbusTCP module. The default value there is 100. Perhaps you are reaching the limit there? The value can be adjusted accordingly. I assume that this value is not accepted in the input dialogue and therefore the 'fixed' limit value 10 is used.
Last updated: 2024-04-10

Post by ara32 on CODESYS 4 Linux: CODESYS Forge talk (Post)
Hello! I managed to correctly launch CODESYS Developer Studio 3.5.17, almost all functionality works. The only issue remaining is that when connecting to a device and obtaining its public key, the NCryptEncrypt function is called, which is not fully implemented in the DLL source code, resulting in the connection not being established. Currently, the code of this function in the Wine repository looks like this: SECURITY_STATUS WINAPI NCryptEncrypt(NCRYPT_KEY_HANDLE key, BYTE *input, DWORD insize, void *padding, BYTE *output, DWORD outsize, DWORD *result, DWORD flags) { struct object *key_object = (struct object *)key; TRACE("(%#Ix, %p, %lu, %p, %p, %lu, %p, %#lx)\n", key, input, insize, padding, output, outsize, result, flags); if (flags & ~(NCRYPT_NO_PADDING_FLAG | NCRYPT_PAD_OAEP_FLAG | NCRYPT_PAD_PKCS1_FLAG | NCRYPT_SILENT_FLAG)) { FIXME("Flags %lx not supported\n", flags); return NTE_BAD_FLAGS; } if (flags & NCRYPT_NO_PADDING_FLAG || flags & NCRYPT_PAD_OAEP_FLAG) { FIXME("No padding and oaep padding not supported\n"); return NTE_NOT_SUPPORTED; } if (key_object->type != KEY) return NTE_INVALID_HANDLE; return map_ntstatus(BCryptEncrypt(key_object->key.bcrypt_key, input, insize, padding, NULL, 0, output, outsize, result, flags)); } The program crashes due to the NCRYPT_PAD_OAEP_FLAG flag. I'm not proficient in C++, but I attempted to add handling myself, and here's the result: SECURITY_STATUS WINAPI NCryptEncrypt(NCRYPT_KEY_HANDLE key, BYTE *input, DWORD insize, void *padding, BYTE *output, DWORD outsize, DWORD *result, DWORD flags) { struct object *key_object = (struct object *)key; TRACE("(%#Ix, %p, %lu, %p, %p, %lu, %p, %#lx)\n", key, input, insize, padding, output, outsize, result, flags); if (flags & ~(NCRYPT_NO_PADDING_FLAG | NCRYPT_PAD_OAEP_FLAG | NCRYPT_PAD_PKCS1_FLAG | NCRYPT_SILENT_FLAG)) { FIXME("Flags %lx not supported\n", flags); return NTE_BAD_FLAGS; } if (flags & NCRYPT_NO_PADDING_FLAG) { FIXME("No padding not supported\n"); return NTE_NOT_SUPPORTED; } BCRYPT_OAEP_PADDING_INFO oaepInfo = { 0 }; oaepInfo.pszAlgId = BCRYPT_SHA1_ALGORITHM; NTSTATUS status = BCryptEncrypt(key_object->key.bcrypt_key, input, insize, &oaepInfo, NULL, 0, output, outsize, result, flags); if (key_object->type != KEY) return NTE_INVALID_HANDLE; return map_ntstatus(BCryptEncrypt(key_object->key.bcrypt_key, input, insize, padding, NULL, 0, output, outsize, result, flags)); } Now, when calling the connection, it crashes with the error "bcrypt:BCryptEncrypt flags 0x4 not implemented." Can anyone help with enhancing this functionality or at least point me in the right direction?
Last updated: 2024-03-22

Post by duvanmoreno24 on Modbus writing on value change CODESYS Forge talk (Post)
Hi all, I want to know if someone has an idea of how I can write on value change in Modbus Codesys. I have a Wago PLC and I was used to work with E-cockpit which it was quite easy to do that without the necessity to trigger any value when there was a change in the variable ( I will put how easy is ). how you can see just changing the trigger in "On value Change" will do that channel writing automatically when It detects a change in those arrays. On the other hand, in Codesys if I enable the rising edge in Codesys It ask me to put a bool variable and if triggers is going to write that value. That is making me that I have to create a function or a logic to detect the change, the problem I have is that doing that is very tedious. I first approach I got it was to create a Function who returns a bool when the value change, but I tried to keep the old value but what is happening is that in Functions all the data is erased every cycle so I can not keep any Old value. so in the Main program the trigger is going to be TRUE all the time due, the old value is cero every cycle. The second approach I got it was using a function Block (POU_1) and it works but I dont want to instance that function for every Channel or value that I want to check if the value change, Basically if I have 200 values to write trhough modbus I have to create 200 instances of that function which I think it is not practicall at all. It should be a better way to implement this as e-Cockpit from Wago Does. However, I haven't been able to know how.
Last updated: 2024-03-26

Post by pietrobalint on Retain / Persistent Variables in Codesys for Raspberry Pi CODESYS Forge talk (Post)
If I select "Update boot aplication" while I download the code the persistent variables got a constant startup value. But during the running I am still not able make the persistent variables to hold they actual value.
Last updated: 2024-09-01

Post by hanpekel on Reading request counter value from modbus server in application CODESYS Forge talk (Post)
Any way I can read the value of the 'request counter' (see screenshot) in my application. Amount of client connections is easily found using ModbusTCP_Slave_Device.uiClientConnections; But for request counter it does not seem to be that simple.
Last updated: 2024-10-16

Post by ton on Length of string and Array of bytes CODESYS Forge talk (Post)
When you use a string value 0 will be the end terminator. Everything after this will not be in the string. I guess byte 2394 has a value 0.
Last updated: 2025-04-01

Post by stribor on Passing properties as VAR_IN_OUT variables. CODESYS Forge talk (Post)
if i only use it as input variable I won't be able to update its state within the visu object. Lets say i have real value as a property, i would like the slider object to display this value and also modify it.
Last updated: 2025-04-30

Post by timvh on Unable to select VisuDialogs.Numpad in Open Dialog input configuration CODESYS Forge talk (Post)
You should not use the "open dialog" to change the value. Instead use the input configuration "Write Variable" to change a variable value in the visualization. in the setting of this input command, you can choose the Input type (select dialog).
Last updated: 2025-07-23

Is there any way to remove the warning for having two enumerators with the same value in the same enum? CODESYS Forge talk (Thread)
Is there any way to remove the warning for having two enumerators with the same value in the same enum?
Last updated: 2016-12-22

Post by marekxc on Little endian to Float from Modbus RTU CODESYS Forge talk (Post)
Maybe try going back to step one and: Var Reg1: WORD; Reg2: WORD; Reg12: DWORD; Value: REAL; end_var // program Reg1:= 4096; Reg2:= 14884; Reg12:= (reg2 * 65536) + reg1; Value:= DWORD_TO_REAL(Reg12);
Last updated: 2023-12-28

Post by t-probst on Strong Private Key Protection for Encryption Certificates CODESYS Forge talk (Post)
Hello, We are trying to implement an automated method of adding of a certificate and private key to the Windows certificate store for encrypting CODESYS projects. We want to do this so that users do not have to deal with details of certificates at all and to prevent user error. We are keen on enforcing strong private key protection since it ensures that a password is required for the certificate to be used to decrypt a CODESYS project. When we add a certificate to the certificate store and enable strong key protection using the Microsoft Management Console Certificates snap-in, it works as expected. However, through this method the user may mistakenly not enable strong private key protection. For the certificates we create programmatically (using Microsoft’s Cryptography Next Generation API in .Net 7) bag attributes are added to the certificate and key by the API. These bag attributes are as follows: Bag Attributes localKeyID: 01 00 00 00 subject=C = xx, ST = xxx, O = xxx, OU = xxx, CN = xxx issuer=C = xx, ST = xxx, L = xxx, O = xxx, OU = xxx, CN = xxx -----BEGIN CERTIFICATE----- [encoded certificate] -----END CERTIFICATE----- After using this certificate with bag attributes to encrypt a CODESYS project, it can’t be decrypted, showing this error: "The specified project could not be loaded. Possible reasons might be: - The project file is corrupted or invalid - The project has been saved with a newer version of the programming system. If this is the case, you can open the project in the corresponding version. Choose "Save as..." with the appropriate storage version, and retry again. - You may not have the necessary permissions to lad the project" We know that the bag attributes are causing the issue because if we manually edit the certificate file to remove them before using the certificate to encrypt a project, the project can be decrypted as expected. However, we are unable to automatically enforce strong key protection using this method. Here is a link to a StackOverFlow question that we have posted recently for this issue: https://stackoverflow.com/questions/76922355/enforcing-strong-private-key-protection-for-x509certificate2-objects-in-net-mod Any help is greatly appreciated.
Last updated: 2023-08-22

Post by dhumphries on Control for Linux SL on Ubuntu Core CODESYS Forge talk (Post)
Try using a password instead of a public key to log into the controller. I have a video showing how to do this on a default installation of Ubuntu server, it should work the same for Ubuntu Core. https://youtu.be/rj0dOhgnGjs?si=352PmveEP7JXZnO- I sign in to the controller at about 6:40 in the video. I have never tried to remove the public key and revert to signing in using a password, but it looks pretty straightforward https://askubuntu.com/questions/745423/how-to-turn-off-password-less-login-for-ssh
Last updated: 2024-02-28

Post by richard-wang on When Keyboard Key is in Hold, then Webvisu is extreme slow and latent CODESYS Forge talk (Post)
Hi Tyro Did you resove your problem? I have the same issue. BR Richard
Last updated: 2023-09-05

Post by drml on Array to String CODESYS Forge talk (Post)
If a size is not specified, CODESYS allocates 80 characters by default for a string. After 7 seconds, does your Json_string contain all of your 20000 key/values? Or is the result truncated to 80 characters?
Last updated: 2024-07-19

<< < 1 .. 4 5 6 7 8 .. 24 > >> (Page 6 of 24)

Showing results of 584

Sort by relevance or date