Post by aliazzz on Unable to deploy Virtual Control SL on ARM64 (Raspberry Pi5)
CODESYS Forge
talk
(Post)
Hi, I have successfully deployed "Virtual Control SL" on a few x86/64 machines now. However, I'd now like to deploy this to a Raspberry Pi (ARM64). To do this I prepared the Raspberry Pi5 with the following prereq's; * Minimal PREEMPT Debian * Latest Bootfirmware * full SSH access via non-root account * Podman * RedHat Cockpit with CODESYS LicensServer plugin up and running However, I can't seem to resolve copying the correct (deploy) Images as they wont show up in the CODESYS IDE I have added CODESYS Virtual Control for Linux SL and the CODESYS LicenseServer for Linux SL via the CODESYS installer on my DevBox. I open CODESYS > Tools > Deploy Control SL Next I enter the SSH targets IP and Credentials and for my RPi5 and it shows "Connected". In the next tab, Deployment, the dropdown box only shows one (1) image, which also is the incorrect CPU architecture. Only Virtual Control AMDx64 shows up (!?) while I expect to see the ARM64 based images for both Edge and Control. Has someone encountered this too? I'd like to hear other people experiences with Virtual Control deployment on ARM based architecture. attachment 1: AMD64 based deployment pulldown menu (correct images) attachment 2: ARM64 based deployment pulldown menu (incorrect images) regards,
Last updated: 2024-07-28
Post by ihatemaryfisher on Sorting array of any-sized structure
CODESYS Forge
talk
(Post)
With that I could make an array of varying size, but would still have to define the array type in the function's declaration VAR_IN_OUT stArray: array [*..*] of <pre-defined data type> END_VAR I wanted a function that could take an array of any type (e.g., a structured VAR) as an input. That way I could call it in multiple POUs to handle different arrays structures.
Last updated: 2023-08-18
Post by mozed on Connection to device closed
CODESYS Forge
talk
(Post)
Hello, Exulting the command /opt/CoDeSysControl/Files/run restart debug I get this response from the linux terminal:(ScreenShot1 to ScreenShot7) When I try to reconnect via codesys this line appears at the linux terminal level:(ScreenShot8) A few seconds later, the error window appears on Codesys.(ScreenShot9) I see that following the command /opt/CoDeSysControl/Files/run restart debug there are errors, are they the problem? Sincerely,
Last updated: 2023-08-24
Post by rossanoparis on How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server
CODESYS Forge
talk
(Post)
Thank you @eschwellinger Even tough I think the content of the link you provided is a bit messy. To bind OPCUA server to a specific adapter, I should have had insert the following section. [CmpOPCUA] NetworkAdapter=eth0 But it doesn't work, I had to insert the following section instead to get the right configuration. [CmpOPCUAServer] NetworkAdapter=eth0 Regards Rossano
Last updated: 2023-08-29
Post by macros8 on Alarm Management - latched variable represented as Text list
CODESYS Forge
talk
(Post)
Hi all, in Alarm management you can latch some variable to show value within the alarm msg. It´s very useful sometime. But I´m wondering whether there is any possibility to represent that value as Text list. It´s quite common in other HMI tools and this is very useful in case of using some ErrorID for detail specification of error. Unfortunately I could not find any way how to do it but I believe that exists :) Thanks a lot. M.
Last updated: 2023-09-06
Post by transmin01 on CANbus issue
CODESYS Forge
talk
(Post)
Update: This initial issue was when using a Linux target PLC. Since then I have created a Win10 target PC and the Codesys software reported an issue associated with the device version (see attached). I am assuming this is an incompatibility with the xml file from the manufacturer and the firmware version on the module and I am chasing this up with Beckhoff. Question is, why would this not report with a Linux target?
Last updated: 2023-09-14
Post by timvh on SafetyApp - "Invalid ERR Ack input"
CODESYS Forge
talk
(Post)
I had a similar error "Invalid ERR Ack input". What you need to do is link an variable from the "non-safe" PLC to the Group IOs of the POU in the Safety app. * Add a POU to the SafetyApp (probably already done, otherwise you don't get this error) * Right click on this POU - select properties * Go to the Group IOs tab * Link a variable to the Err.Ackn. input I don't know about the Size of zero, I didn't get this error. Were you able to fix this?
Last updated: 2023-11-16
Post by fred on Rasperry Control Debian 12
CODESYS Forge
talk
(Post)
Hi, I have Proxmox running on a Rasperry 4 and have debian 12 ARM installed here. I wanted to install Codesys Control for Raspberry on it. According to the messages, the runtime environment and the gateway were installed successfully, but I can't find a device to downplay a program. The sudo service codesys start command fails. (see image) Does somebody has any idea? Thank you for your help! Greetings Fred
Last updated: 2023-11-22
Post by macros8 on Alarm Management - Import and Export of AlarmGroup
CODESYS Forge
talk
(Post)
Hi, I struggle with exporting my Alarm Messages and following importing back to my project. Because filling in one by one is very time consuming I want to use export function and edit .csv file in Excel. As soon as I modify the file the import back to project does not work at all and function returns errors. Would you pls give me a hint how to properly use this functionality? Thanks a lot for help. Regards, M.
Last updated: 2023-12-02
Post by mmoncada on Dinamically loading recipes
CODESYS Forge
talk
(Post)
I'm having trouble with the initial loading of recipes. I can create them and load one or the other, but when the program restarts the recipes are not listed. I'm calling: RecipeManCommands.ReloadRecipes and then RecipeManCommands.GetRecipeCount which returns 0 recipes. None of the methods returns error and if i call them again after RecipeManCommands.CreateRecipe RecipeManCommands.ReadAndSaveRecipe getRecipeCount returns the number of recipes created. When i restart the system, once again they are not listed even though the recipe files are there. Any ideas? Martin Btw, Codesys 3.5 SP 16 Path 9
Last updated: 2023-12-06
Post by nz-dave on Bool turning on in case stament in wrong state?
CODESYS Forge
talk
(Post)
I have a case statement running a process. during one of the steps it has started calling a bool var that is 2 steps further on in the case? i have even tried //commenting it out but it still turns on at the same point in the case. i have also run a trace but cant see anything that would trigger it. Any Ideas? Cheers
Last updated: 2023-12-15
Post by svn123 on In Simulation Mode, logic is not executing
CODESYS Forge
talk
(Post)
Please check the attached snapshot. I am converting an int to real and storing in rVlv01_SV and then scaling the value using LIN_TRAFO. In the bottom Status Bar of Codesys, both RUN and SIMULATION are visible. When I enter value 100 as input to INT_TO_REAL instruction and press Ctrl-F7, the value can be seen at the input but the logic seems not to work. I searched for help but could not find anything relevant. What could be the reason. Codesys ver3.5.11 svn
Last updated: 2023-12-25
Post by usacodesysuser on How to connect serial devices ?
CODESYS Forge
talk
(Post)
@eschwellinger do you have any examples of using a USB barcode scanner? I have read through the forums here and I am unable to find how to get the barcode data to populate in a text field without having to first click into the text field to activate it. Is there a library that allows you to access the barcode data? I am really new to this in general any help is greatly appreciated, hopefully you have a pretty clear example
Last updated: 2024-01-06
Post by apurv on Cannot pass array of constant size to a function as a reference
CODESYS Forge
talk
(Post)
I have a Array of constant size defined like this Var Constant MAX_SIZE :UINT := 10; End_var VAR array : ARRAY[0..MAX_SIZE] OF INT; END_VAR Now I want to pass this array to a function by reference, Function fun : INT VAR_IN_OUT CONSTANT MAX_SIZE : UINT; END_VAR VAR_INPUT array : REFERENCE TO ARRAY[0..MAX_SIZE] OF INT; END_VAR but when I run this it gives strange Errors Error : Cannot Convert type 'ARRAY [0..MAX_SIZE] OF INT' to type 'ARRAY[0..MAX_SIZE] OF INT'
Last updated: 2024-01-07
Post by felipemsgarcia on Edge Gateway online, but PLC is not online
CODESYS Forge
talk
(Post)
Hello, I couldn't figure what/where the issue was, so I deleted everything from automation server and reinstalled the edge gateway and did the process again. It worked for about a month and then it stopped working again. It presents the same symptom, edge gateway is online but I can't connect to the PLC. Any idea of what could be the issue? Thank you!
Last updated: 2024-01-09
Post by toby on Codesys Control Raspberry PI 4.10.0 - missing 'Update Raspberry PI' option
CODESYS Forge
talk
(Post)
Hi Edwin, Thanks for the message. My apologies I should have researched this more thoroughly before posting on here. I found a solution to my issue on this post: https://forge.codesys.com/forge/talk/Runtime/thread/6455efaa17/ I needed to run the 'CODESYS Installer' as an Admin, then install the RPi package v4.10.0 in to my package (v3.5 SP19 Patch 5). Thanks, hope you have a good day. Toby
Last updated: 2024-01-09
Post by jaspergain on Access to the path *** is denied
CODESYS Forge
talk
(Post)
Hello, Recently I upgraded to 3.5.19.50 and have been having errors/issues when doing a download/online change. The message as seen in the attachment pops up. The file in the path is different every time. However when I login again afterwards all works fine. This issue does not happen on older versions. Any clue what the issue could be? I did an reinstall/repair but the issue reappeared again... Thanks in advance!
Last updated: 2024-01-25
Post by jinlee on Multiple WebVisu
CODESYS Forge
talk
(Post)
Hi, thank you for replying. Basically, I have a main visu with frame selection. So, under some condition the frame will switch to a specific frame. It used to be controlled by variable using "Switch frame variable". However, I realise it will change all the HMI screen at one time. So I removed the variable, and still looking for a solution to do that. Do you have any idea?
Last updated: 2024-02-06
Post by jinlee on How do you get the CURRENT ClientData?
CODESYS Forge
talk
(Post)
Hi there, I wonder how to use this CURRENTCLIENTID. However, what I am trying to do is to use PLC_PRG.aIndexVisu[CURRENTCLIENTID]. to switch the frame within the mainpage without affecting the other screen same as the first question of this post. However, I failed to do it. Can you tell me how to do it ? Or can you advise me on this issue
Last updated: 2024-02-07
Post by otdeveloper on IEC 61499
CODESYS Forge
talk
(Post)
It is being worked on by many companies and its even-driven function blocks seem like a natural evolution of the object oriented industrial programming I have seen Gary Pratt (author of the Book of CODESYS and much more) so expertly implement and explain. I would expect CODESYS to have this front and center on their sights and, if they do not, I would be very interested in learning why.
Last updated: 2024-02-09
Post by matthew on New Ladder Diagram conversion does not work due to missing features
CODESYS Forge
talk
(Post)
Hi @eschwellinger, I have been trying out v1.0 of the new ladder and have a few questions. I have warnings Expression or part of it has no effect I can't get rid of them, what do they exactly mean? Using the ST_Block, is there a way when online to open the ST_Block and view the running code? Thanks!
Last updated: 2024-02-09
Post by kleeswi on SysFileOpen does not work after update to V3.5 SP19 Patch 5
CODESYS Forge
talk
(Post)
I use the function SysFile.SysFileOpen(sFileNamePara, SysFile.ACCESS_MODE.AM_WRITE, pErrorFileOpen); to open and write a file. Since the update from Codesys V3.5 SP17 to V3.5 SP19 Patch 5 it does not work anymore. I first had SysFile.SysFileOpen(sFileNamePara, SysFile.ACCESS_MODE.AM_APPEND_PLUS, pErrorFileOpen); in both versions. hFile_Test is a pointer to byte. It gives an exceptional error when dereferencing the hFile_Test pointer. Edit: I use Codesys on a Raspberry pi
Last updated: 2024-02-19
Post by dhumphries on Control for Linux SL on Ubuntu Core
CODESYS Forge
talk
(Post)
Try using a password instead of a public key to log into the controller. I have a video showing how to do this on a default installation of Ubuntu server, it should work the same for Ubuntu Core. https://youtu.be/rj0dOhgnGjs?si=352PmveEP7JXZnO- I sign in to the controller at about 6:40 in the video. I have never tried to remove the public key and revert to signing in using a password, but it looks pretty straightforward https://askubuntu.com/questions/745423/how-to-turn-off-password-less-login-for-ssh
Last updated: 2024-02-28
Post by alexgooi on Disable OPC-UA server
CODESYS Forge
talk
(Post)
Dear Forum, I recently updated to the newest Codesys IDE (3.5 SP19 patch 5) The program wouldn't download cause of the amount of OPC-UA server tags (see picture) I'm not planning on using the OPC-UA server and therefore I unchecked the "Support OPC-UA features" checkbox in the symbol configuration. But this didn’t solve the issue of the OPC-UA server exceeding its license. How can I disable the OPC-UA server while still maintaining the symbol configuration. Thank you in advance Alex
Last updated: 2024-03-01
Post by camilloo on Control for Linux SL on Ubuntu Core
CODESYS Forge
talk
(Post)
(dhumphries) I followed your advice and tried it on Ubuntu Server. Was a good choice. Your material was also very helpful :). Thanks for Your help! I no longer have problems connecting to Ubuntu. However, I still cannot install Virtual PLC. I'm currently getting a missing path message: "C:\Program Files\CODESYS 3.5.19.60\CODESYS\CODESYS Virtual Control for Linux SL\Delivery\virtuallinux\VirtualControlAPI.py." It looks as the package: "CODESYS Virtual Control for Linux SL" was not installed. But, there isn't one in CODESYS Store or I'm doing something incorrectly.
Last updated: 2024-03-03
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.