Post by dhumphries on Toggling Visualizations using HMI Physical Buttons CODESYS Forge talk (Post)
Nothing wrong with ladder, in a lot of applications it is simpler than ST or CFC, you're a lot less likely to have syntax issues in a ladder diagram than in structured text as long as you stick with traditional ladder elements. Your attempt was almost valid, but you tried to change the currentvisu variable using a blend of structured text and ladder, which isn't allowed. You need to use the MOVE operator and define the visualization name as a string on the input side and the visuelems.currentvisu as the target on the output side.
Last updated: 2024-02-28

Post by wmoon on Licensing info not available. CODESYS Forge talk (Post)
Hello, I bought some licenses from CODESYS store. I am trying to install licenses into my device(CODESYS Control for Linux ARM64 SL). But I have a trouble with it. I did it in the following order. Tool -> License Manager Selected Device and Next... Selected Soft container and Next... Select the device and Ok.. And then I always show a message "Licensing info not available. There is no dongle attached to the device." And I tried to click "Install Licenses" button. I saw the message "The value cannot be NULL. Parameter name : continerToLicenses" Could you let me know what I've missed or what I've got wrong?
Last updated: 2024-03-19

Post by wollvieh on Raspi Pi Bullseye Webvisu Autostart CODESYS Forge talk (Post)
Anbei meine Lösung zum Autostart der Webvisu, vllt. hilft es jemandem... =============================== Raspberry Pi Bullseye 11 Autostart Codesys Webvisu im Kiosk Mode 1)Datei erstellen: sudo nano/etc/xdg/autostart/Visustart.desktop 2)Inhalt der Datei: [Desktop Entry] Type=Application Name=Visustart Exec=bash -c "sleep 30 && /home/pi/Desktop/Visu" 3)Visu Datei erstellen sudo nano /home/pi/Desktop/Visu 4) Inhalt der Datei: #!/bin/sh xset -dpms xset s off xset s noblank matchbox-window-manager -use_titlebar no & unclutter & chromium-browser -display=:0 --kiosk --incognito --window-positon=0,0 5) Datei ausfĂŒhrbar machen sudo chmod+x /home/pi/Desktop/Visu ... nach Neustart Raspi startet die Codesys Webvisu automatisch im Kiosk Mode ===============================
Last updated: 2024-03-24

Post by wollvieh on Raspi Pi Bullseye Webvisu Autostart CODESYS Forge talk (Post)
Anbei meine Lösung zum Autostart der Webvisu, vllt. hilft es jemandem... =============================== Raspberry Pi Bullseye 11 Autostart Codesys Webvisu im Kiosk Mode 1)Datei erstellen: sudo nano/etc/xdg/autostart/Visustart.desktop 2)Inhalt der Datei: [Desktop Entry] Type=Application Name=Visustart Exec=bash -c "sleep 30 && /home/pi/Desktop/Visu" 3)Visu Datei erstellen sudo nano /home/pi/Desktop/Visu 4) Inhalt der Datei: #!/bin/sh xset -dpms xset s off xset s noblank matchbox-window-manager -use_titlebar no & unclutter & chromium-browser -display=:0 --kiosk --incognito --window-positon=0,0 5) Datei ausfĂŒhrbar machen sudo chmod+x /home/pi/Desktop/Visu ... nach Neustart Raspi startet die Codesys Webvisu automatisch im Kiosk Mode ===============================
Last updated: 2024-03-24

Post by saugat10 on Cannot install Codesys control Multicore in raspberry pi 4 CODESYS Forge talk (Post)
I have raspberry pi 4 with Raspbian 12 (bookworm). I want to install the latest version of codesys control 4.11.0.0 multicore for 32 bit. I cannot install multicore and it only gives me the option to install Standard. Here are some outputs from the pi pi@saugat:/usr $ uname -a Linux saugat 6.6.20+rpt-rpi-v7l #1 SMP Raspbian 1:6.6.20-1+rpt1 (2024-03-07) armv7l GNU/Linux pi@saugat:~ $ cat /etc/os-release PRETTY_NAME="Raspbian GNU/Linux 12 (bookworm)" NAME="Raspbian GNU/Linux" VERSION_ID="12" VERSION="12 (bookworm)" VERSION_CODENAME=bookworm ID=raspbian ID_LIKE=debian HOME_URL="http://www.raspbian.org/" SUPPORT_URL="http://www.raspbian.org/RaspbianForums" BUG_REPORT_URL="http://www.raspbian.org/RaspbianBugs" A
Last updated: 2024-04-22

Post by ppix on Establishing TLS Connection with MQTT Broker using MQTT Client SL Package CODESYS Forge talk (Post)
For anyone confused with the process visit this link (the bottom section about creating a .pfx file) https://content.helpme-codesys.com/en/LibDevSummary/certificate.html#import-of-client-certificates-with-private-key. I solved this problem by creating a .pfx file and importing it into the security store under 'Own Certificates'(must have SP18 or newer to import .pfx). I used a gitbash shell to enter the openssl command that created the .pfx file. Once you import the file, in your TLS context, set your 'sUseCaseName' to be the same as the name listed in the 'Information' column of your imported certificate. This did it for me
Last updated: 2024-06-20

Post by naks on Change IP address from IEC code CODESYS Forge talk (Post)
Hi, I'm working with wago 750-8212 controller. I want to change the IP address of the Ethernet adapter from webvisu. I have read some other threads in this forum and I have tried the following: Added the following text to the config file CODESYSControl.cfg: [SysSocket] Adapter.0.Name="br1" Adapter.0.EnableSetIpAndMask=1 Used the below code : IF xUpdateEthernet THEN Ethernet.Enable := FALSE; Reconfig ( xExecute := TRUE, itfNode := Ethernet, eError => ErrorReconfig, xBusy => xBusy, xDone => xDone, xError => xErrorReconfigure); IF Reconfig.xDone THEN ErrorCode := Ethernet.UpdateConfiguredIPSettings(IpAddress := NewIp, gateway := newGateway, subnetmask := newSubnetmask); END_IF IF Reconfig.xDone OR Reconfig.xError THEN reconfig(xExecute := FALSE); END_IF Ethernet.Enable := TRUE; Reconfig(xExecute := TRUE, itfNode := Ethernet ); END_IF I could change the IP address but when i restart my Controller then the IP address resets to the original, Is there anything I have missed, what else can i try ? Thank you in advance.
Last updated: 2024-07-08

Post by khaledkhalil on Question about the hairaichy of UaExpert CODESYS Forge talk (Post)
Hello, I am Examining this Example from Codesys Tutorial about OPC-UA server here https://www.youtube.com/watch?v=aJhzN3Uk-Do&list=PLWtD08CpmZcSV26aWh1axCAef5c5HxX-3&index=1&t=1167s. Now i am running to problem, when i create instances and i want them to appear directly under the object directory, However, it always appear with me under Objects >> Device set >> Device Name in CODESYS. I need to know how i can change the directory of my instances 'inst_3' and so on. So they can be under objects directly. I tried to modify the settings, but couldn't find any leads till now. Thanks in advance for helping
Last updated: 2024-09-12

Post by jari-koivuluoma on Newly created texlists wont appear in the selection dropdown CODESYS Forge talk (Post)
When I create a new textlist in Codesys 3.5 SP19 Patch 5, it wont appear in the dropdown menu at Rectangle element > Dynamic texts > Text list. If I just type the name of the textlist to the field (in quotes), I get an error saying that some file is missing. Any good ideas what to do and what is going on. I recently updated to that version and I only now noticed this when I needed to add a new textlist so Im quite screwed with this not being able to add text lists. While im typing this, I tried copying an existing list and modifying it and it seems to show. Any ideas?
Last updated: 2024-09-19

Post by thn-power on How to change OPC NodeId IdentifierType CODESYS Forge talk (Post)
Hi Yet another OPC UA question. When setting up a OPC server using "Communcation manager" (Symbol set and information model) in Codesys the NodeId is always given as "opaque" type. At least when browsing using UAExpert. Other standard OPC objects use numeric (or string) identifier, but for some reason my variables seems to get opaque/binary type. See attached photo. How can I change this? I can't see that this is a parameter in the CodesysControl.cfg. Can this be specified in the information model nodeset? And is it possible to specify the exact numeric or string NodeId for each instance? And on a related topic, is there a way to export the OPC server nodeId's with variable name so that it can be imported in a OPC Client? The .xml files in the project folder does not seem to contain the NodeId.
Last updated: 2024-09-20

Post by timvh on FB string and naming CODESYS Forge talk (Post)
I see, you want to initialize the FB. To be able to initialise it like you described, you need to add the FB_Init method to your FB. (right click on the FB, select add object --> method). Then press the arrow down, to select the FB_Init (overwrite default implementation). In the VAR_INPUT section of this method, add the variable --> Tag : STRING; Then in the code section of this method add: THIS^.Tag := Tag; // copy initial value to local variable in FB Search Google if you want to know more about FB_Init. PS, reflection + instance path, is also an option if you want to get the full name of the instance (path) of the Function Block. See: https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_pragma_attribute_instance_path.html
Last updated: 2024-09-30

Post by yoeri on Refresh visulization realtime CODESYS Forge talk (Post)
Hi everyone, I need some help with displaying an image (test.png) on my device. Initially, showing the image is straightforward. However, I want to be able to update the image dynamically. My goal is to send updated files via FTP to the device, and have the display automatically show the latest version of the image. All images will be sent with the same name (e.g., test.png). Currently, I can see the updated image after sending it via FTP and performing a warm restart, but I'd like to achieve this in runtime, without having to restart the display or application. Does anyone have suggestions on how to implement this? Thanks in advance!
Last updated: 2024-10-21

Post by fefefede on Get the numer of day CODESYS Forge talk (Post)
Hello i tro to create a program to turn on or off the air condition in relationship temperature and numer of day. I can't get the number of day. I try this after installing SysTime library but this not work and have this error on debug ------ Build started: Application: Device.Sim.Device.Application ------- Typify code... Generate code... [ERROR] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0032: Cannot convert type 'Unknown type: 'SysTimeCore(TRUE)'' to type 'TIME' [ERROR] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0035: Program name, function or function block instance expected instead of 'SysTimeCore' [ERROR] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0032: Cannot convert type 'Unknown type: 'DayOfWeek(CurrentTime)'' to type 'INT' [ERROR] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0035: Program name, function or function block instance expected instead of 'DayOfWeek' [INFORMATION] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0181: Related position Build complete -- 4 errors, 0 warnings : No download possible PROGRAM PLC_PRG VAR Temperatura: UDINT; AriaCondizionata: BOOL := FALSE; CurrentDayOfWeek: INT; //Variabile Giorno CurrentTime: TIME; GiornoDellaSettimana: INT; DayOfWeek: INT; END_VAR CurrentTime := SysTimeCore(TRUE); // Ottieni l'ora corrente CurrentDayOfWeek := DayOfWeek(CurrentTime); CASE GiornoDellaSettimana OF 1: // Azioni per LunedĂŹ 2: // MartedĂŹ se piĂč 10° accend altrimenti spegni IF Temperatura >= 10 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 3: // MercoledĂŹ se piĂč di 50° accendi altrimenti spegni IF Temperatura >=50 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 4: // GiovedĂŹ se piĂč di 40° accendi altrimenti spegni IF Temperatura >=40 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 5: // VenerdĂŹ se piĂč di 50° accendi altrimenti spegni IF Temperatura >=50 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 6: // Sabato se piĂč di 25° accendi altrimenti spegni IF Temperatura >=25 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 7: // Domenica sempre spenta AriaCondizionata := FALSE; END_CASE
Last updated: 2023-09-14

Post by full0pullpolen on Device User Logon CODESYS Forge talk (Post)
The following guide describes how you can adapt the user management for the first time in a project. It deals with the definition of a user and a group to which he belongs. Requirement: the project for which the user management is to be set up is opened. There is no adapted user configuration yet. Select Project Settings ‣ Users and Groups and then the Users tab. The user Owner is already created by default. Click on Add. ⇒ The dialog box Add User appears. Enter a login name, for example ‘Dev1’, and a password. Leave the option Activated activated. Click on OK. ⇒ On creating a group for the first time, CODESYS now requests you to authenticate yourself to perform this action. In this case, enter ‘Owner’ as the current user. Do not enter a password, just click on OK. The user Dev1 appears in the list and is automatically a member of the group 'Everyone'. Change to the tab Groups, in order to add the user to a new group. ⇒ The groups Everyone and Owner have already been created. Click on Add in order to open the dialog box Add Group. Specify at least one name for the new group, for example ‘Developers’. Activate the checkbox next to the entry User ‘Dev1’ in the field Members. Click on OK. ⇒ The group Developers now appears with has user member 'Dev1'. Switch to the Users tab. ⇒ The user Dev1 now appears as a member of the groups ‘Everyone’ and ‘Developers’.
Last updated: 2024-01-24

Post by full0pullpolen on Device User Logon CODESYS Forge talk (Post)
The following guide describes how you can adapt the user management for the first time in a project. It deals with the definition of a user and a group to which he belongs. Requirement: the project for which the user management is to be set up is opened. There is no adapted user configuration yet. Select Project Settings ‣ Users and Groups and then the Users tab. The user Owner is already created by default. Click on Add. ⇒ The dialog box Add User appears. Enter a login name, for example ‘Dev1’, and a password. Leave the option Activated activated. Click on OK. ⇒ On creating a group for the first time, CODESYS now requests you to authenticate yourself to perform this action. In this case, enter ‘Owner’ as the current user. Do not enter a password, just click on OK. The user Dev1 appears in the list and is automatically a member of the group 'Everyone'. Change to the tab Groups, in order to add the user to a new group. ⇒ The groups Everyone and Owner have already been created. Click on Add in order to open the dialog box Add Group. Specify at least one name for the new group, for example ‘Developers’. Activate the checkbox next to the entry User ‘Dev1’ in the field Members. Click on OK. ⇒ The group Developers now appears with has user member 'Dev1'. Switch to the Users tab. ⇒ The user Dev1 now appears as a member of the groups ‘Everyone’ and ‘Developers’.
Last updated: 2024-01-24

Post by full0pullpolen on Device User Logon CODESYS Forge talk (Post)
The following guide describes how you can adapt the user management for the first time in a project. It deals with the definition of a user and a group to which he belongs. Requirement: the project for which the user management is to be set up is opened. There is no adapted user configuration yet. Select Project Settings ‣ Users and Groups and then the Users tab. The user Owner is already created by default. Click on Add. ⇒ The dialog box Add User appears. Enter a login name, for example ‘Dev1’, and a password. Leave the option Activated activated. Click on OK. ⇒ On creating a group for the first time, CODESYS now requests you to authenticate yourself to perform this action. In this case, enter ‘Owner’ as the current user. Do not enter a password, just click on OK. The user Dev1 appears in the list and is automatically a member of the group 'Everyone'. Change to the tab Groups, in order to add the user to a new group. ⇒ The groups Everyone and Owner have already been created. Click on Add in order to open the dialog box Add Group. Specify at least one name for the new group, for example ‘Developers’. Activate the checkbox next to the entry User ‘Dev1’ in the field Members. Click on OK. ⇒ The group Developers now appears with has user member 'Dev1'. Switch to the Users tab. ⇒ The user Dev1 now appears as a member of the groups ‘Everyone’ and ‘Developers’.
Last updated: 2024-01-24

Post by umdee on Error when monitoring LAD programs CODESYS Forge talk (Post)
I get the following error when monitoring my program (see attached screenshots): "Unhandled exception has occured in your application. If you click Continue, the application will ignore this error and attempt to continue. If you click Quit, the application will close immediately. Value cannot be null. Parameter name: source. And the details say: See the end of this message for details on invoking just-in-time (JIT) debugging instead of this dialog box. ** Exception Text ** System.ArgumentNullException: Value cannot be null. Parameter name: source at System.Linq.Enumerable.Any[TSource] (IEnumerable1 source, Func2 predicate) at _3S.CoDeSys.NWLEditor.NWLTextCell.OnPaintCellLayer(PaintEventArgs e) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.OnPaint(PaintEventArgs e) at System.Windows.Forms.Control.PaintWithErrorHandling(PaintEventArgs e, Int16 layer) at System.Windows.Forms.Control.WmPaint(Message& m) at System.Windows.Forms.Control.WndProc(Message& m) at System.Windows.Forms.UserControl.WndProc(Message& m) at _3S.CoDeSys.Controls.Controls.GfxEdControl.WndProc(Message& m) at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam) ** Loaded Assemblies ** (3000 lines of assemblies) ** JIT Debugging ** To enable just-in-time (JIT) debugging, the .config file for this application or computer (machine.config) must have the jitDebugging value set in the system.windows.forms section. The application must also be compiled with debugging enabled. For example: <configuration> <system.windows.forms jitdebugging="true"> </system.windows.forms></configuration> When JIT debugging is enabled, any unhandled exception will be sent to the JIT debugger registered on the computer rather than be handled by this dialog box The windows show red X's where the networks should be. Any advice on how to fix this? Additional Information PLC used: Wago 750-8212, Firmware FW26 Startup profile: CODESYS V3.5 SP19 Patch 5 OS version: Microsoft Windows NT 10.0.22631.0 .NET version: 4.0.30319.42000 Full Version info attached as .txt
Last updated: 2024-03-17

Post by hwillems on Ranges, Lambdas, on Fixed arrays of structs CODESYS Forge talk (Post)
I do datastructures and algorithms in Codesys. For example a Struct of Person with thing's like IdNumber, Name, Age etc. as example. Now i do all kind of calculations, filters. So i have this pretty big Fixed Array with Structs. On this struct i want to do simple stuff you can do easily in C++/Python/Rust etc. For example i want to do this: AvererageAge := Average(Peoples.Age); Then it will return the average of all members ages. Or Sort struct on age etc. Or sort on alphabetical Name. Or use Lambda functions to filter/mutate out things like, filter out everybody above 18 years old. Or remove people who it's name start with "A". Currently i have to write my own custom function for example sorting on Age. And make a super specific function based on that particulare datastructure. Here an Example: (*Before calling this FIlter method, set the mNodeFilterSwitch to the desired filter.*) CASE mNodeFilterSelect OF (********************************[ Status Filters ]***********************************) NodeID: FOR x := ACS_OUT_BEGIN TO ACS_OUT_END BY 1 DO FOR y := ACS_IN_BEGIN TO ACS_IN_END BY 1 DO IF marrNode[y].Status.oiNodeID > marrNode[y + 1].Status.oiNodeID THEN mNodeTemp := marrNode[y + 1]; marrNode[y + 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; Started: FOR x := DES_OUT_BEGIN TO DES_OUT_END BY -1 DO FOR y := DES_IN_BEGIN TO DES_IN_END BY -1 DO IF marrNode[y].Status.oxStarted > marrNode[y - 1].Status.oxStarted THEN mNodeTemp := marrNode[y - 1]; marrNode[y - 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; Starting: FOR x := DES_OUT_BEGIN TO DES_OUT_END BY -1 DO FOR y := DES_IN_BEGIN TO DES_IN_END BY -1 DO IF marrNode[y].Status.oxStarting > marrNode[y - 1].Status.oxStarting THEN mNodeTemp := marrNode[y - 1]; marrNode[y - 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; END_CASE; I have like 30+ of these in the enum. Not really DRY code right? These are custom made bubble sort filters in a function. You pass in the Datastructure, and say what function you want. (This is an enum collection of sorting functions) And then the Array with Nodes of Structs gets ordered. Why can't we have Iterators and Lambda's and build in standard functions like regular languages? Also i use bubble sort because it's the easiest to implement because i can't get this to code DRY. Problem with ST (Even the new one with classes) that it's very limited for programming datastructures and algorithms. Yes you still not want dynamic memory and you need to choose the correct algorithm so you know the most extreme edge cases regarding the time it takes to execute the algorithms.(Real-time execution) How are other people dealing with this? Here for example saw some software using an adjusted ST language and having FOR EACH possibility: https://www.fernhillsoftware.com/help/iec-61131/structured-text/st-for-each.html You can then build your own custom Iterator functions. I wish the IEC 61131-3 standard would be more expressive and having more standard modern features, but still keep close to the fact of no dynamics memory and real-time systems.
Last updated: 2023-08-31

Post by timvh on Detect "Cancel" Press in FileOpenSave Dialog CODESYS Forge talk (Post)
Maybe there is a better way, but a long time ago I created a test application that worked like this: With a button I opened the dialog and I added a "Input configuration - OnDialogClosed" "Execute ST-Code" action to this same button which called the following Function when the dialog was closed: F_OnFileDialogClosed(pClientData); Below this Function which handled the result: // This function is called from the visualization when the dialog is closed. FUNCTION F_OnFileDialogClosed : BOOL VAR_INPUT pClientData : POINTER TO VisuElems.VisuStructClientData; END_VAR VAR dialogMan : VisuElems.IDialogManager; FileOpenCloseDialog : VisuElems.IVisualisationDialog; result : VisuElems.Visu_DialogResult; _sFileName : STRING(255); END_VAR // the DialogManager is provided via the implicitly available VisuManager dialogMan := VisuElems.g_VisuManager.GetDialogManager(); IF dialogMan <> 0 AND pClientData <> 0 THEN FileOpenCloseDialog := dialogMan.GetDialog('VisuDialogs.FileOpenSave'); // gets the FileOpenSave dialog IF FileOpenCloseDialog <> 0 THEN result := FileOpenCloseDialog.GetResult(); // gets the result (OK, Cancel) of the dialog IF result = VisuElems.Visu_DialogResult.OK THEN // Original code gvlFile.FileListProvider(); _sFileName := CONCAT(gvlFile.FileListProvider._stDirectory, gvlFile.FileListProvider.stFile); // do something with this file name... END_IF END_IF END_IF
Last updated: 2023-09-19

Post by damian177 on Codesys and SMS in RPi CODESYS Forge talk (Post)
I tried initialize my GSM modem by write simple application in C, and GSM modem works, below used AT commands: AtChat: T : "AT" AtChat: F : "OK" AtChat: T : "AT+CMEE=1" AtChat: F : "OK" AtChat: T : "AT+CMGF=0" AtChat: F : "OK" AtChat: T : "AT+CGMI" AtChat: F : "WH_Ltd" AtChat: F : "WH_GM35" AtChat: F : "Revision: RDA BV5" AtChat: F : "OK" AtChat: T : "AT+CGMM" AtChat: F : "WH_GM35" AtChat: F : "OK" AtChat: T : "AT+CGMR" AtChat: F : "Revision: GM35-D_B5_R05_A01_D170914" AtChat: F : "OK" AtChat: T : "AT+CGSN" AtChat: F : "868221045990218" AtChat: F : "OK" AtChat: T : "AT+CNMI=2,1,0,1,0" AtChat: F : "OK" AtChat: T : "AT+CLIP=1" AtChat: F : "OK" AtChat: T : "AT+COPS?" AtChat: F : "+COPS: 0,2,\"26002\"" AtChat: F : "OK" operator name: "26002" AtChat: T : "AT+CREG?" AtChat: F : "+CREG: 1,1" AtChat: F : "OK" at+creg Modem is initialized I do not understand why Codesys SMS library send AT+CPIN? command ?
Last updated: 2023-09-29

Post by nizrahel on OpC UA server on Raspberry Pi 64 SL runtime CODESYS Forge talk (Post)
Hi all! I'm working on an home project using a Raspberry Pi 3 device with Codesys for Raspberry Pi 64 SL runtime. I would like to create the HMI interface with Siemens WinCC Unified (or Advanced) configuring the Raspberry as OPC UA server. I tryed everything, but I didn't find the way to let the OPC UA connection works using UaExpert. I tryed to use anonymous connection, authenticated connection and the ip address instead of the server name in the path connection. There is no way to connect to the OPC UA server and I was asking myself if this feature is really supported for the runtime version used. Another strange thing I noted, is that is not possible to quickly create an OPC UA certificate in the Security Screen, as show in any tutorials. I have correctly created the Symbol Configuration enabling the OPC UA feature. I attach to this topic some printscreen of the actual configuration (sorry for the italian language interface, but I didn't find the way to switch to english). Thank you very much in advance for your support and advices!
Last updated: 2023-12-03

Post by timl on BacNet "Unaufgelöste Referenz" CODESYS Forge talk (Post)
Hallo, ich habe Probleme beim nachbauen des BacNet2 Tutorials "Erste Schritte" aus der CODESYS Online Help. https://content.helpme-codesys.com/de/CODESYS%20BACnet/_bacnet_first_steps.html Das Anlegen des BacNet2 Servers und der danach folgenden BacNet Datenpunkte erfolgt ohne Probleme. Der Code lĂ€sst sich mit F11 auch Fehlerfrei generieren. Beim Download auf die SPS tritt dann der Fehler auf dem Bild auf. Anbei auch ein Bild des Logs nach dem Download. CODESYS BACnet 2.0.0.0 ist ĂŒber den Installer runtergeladen. Device: CODESYS Control Win V3 x64 Version 3.5.19.40 CODESYS 3.5.19.40 Im Bibliotheksverwalter ist BACnet2 2.0.0.0 aufgefĂŒhrt Die Konfigurationsdatei habe ich mit folgenden anpassungen abgespeichert: [ComponentManager] Component.1=CmpTargetVisuStub Component.2=CmpWebServer Component.3=CmpWebServerHandlerV3 Component.4=SysCpuMultiCore Component.5=SysReadWriteLock Component.6=SysCpuBreakpoints Component.7=SysPipeWindows ;Component.8=CmpHilscherCIFX ;Component.9=CmpPCANBasicDrv ;Component.10=CmpCANFoxDrv ;Component.11=CmpIxxatCANDrv ;Component.12=CmpBlkDrvCanServer ;Component.13=CmpBACnet Component.14=CmpBACnet2 [CmpBACnet2] ;configuration file of the BACnet stack IniFile=$PlcLogic$/bacstac2.ini ;task priority of the BACstack process task, default: TASKPRIO_NORMAL_END (159) TaskPrio=128 ;name of the named pipe for the communication with the BACstack AppName=/tmp/BACnetServer Habe ich etwas vergessen?
Last updated: 2024-02-16

Post by xnoop on MBTCP Slave configuration CODESYS Forge talk (Post)
Hello, I use Codesys 3.5 SP18 Patch 4 (64 bit) My Codesys project is composed of several dozen of Modbus TCP Slaves. I want to configure each of them by define : - Modbus TCP Slave Configuration : Name, IPAddress, port - Channels - Mapping I can't afford to configure manually and I need to find automatic way What possibilities does the Codesys offer? 1. I know it possible to use python script to create Modbus TCP Master and Slave. But I don't find anyway to create Channels and Mapping through the API 2. I 've tested to set mapping with file.csv on a Modbus Tcp Slave, but no way to import channels definition from file 3. I 've tried to use PLCOpenXml file. For example I 've create a project with an Ethernet device. I've exported it in PlcOpenXml file. After delete the Ethernet device, I've imported the PlcOpenXml file without success. I've tried the same by creating Modbus TCP Slave. Could you help me to find to good way ? Thanks
Last updated: 2024-06-19

Post by svenkaro on Codesyscontrol.service stoppt nach 30s CODESYS Forge talk (Post)
Wie Du schon vermutet hast, es meint, die Hardware/Firmware sei nicht kompatibel ... ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-18, 0x00000BB8, 0xFFFFFFFB) Architecture: aarch64 Byte Order: Little Endian CPU(s): 4 On-line CPU(s) list: 0-3 Vendor ID: ARM Model name: Cortex-A72 Model: 3 Thread(s) per core: 1 Core(s) per cluster: 4 Socket(s): - Cluster(s): 1 Stepping: r0p3 CPU(s) scaling MHz: 40% CPU max MHz: 1500.0000 CPU min MHz: 600.0000 BogoMIPS: 108.00 Flags: fp asimd evtstrm crc32 cpuid Caches (sum of all): L1d: 128 KiB (4 instances) L1i: 192 KiB (4 instances) L2: 1 MiB (1 instance) Vulnerabilities: Gather data sampling: Not affected Itlb multihit: Not affected L1tf: Not affected Mds: Not affected Meltdown: Not affected Mmio stale data: Not affected Retbleed: Not affected Spec rstack overflow: Not affected Spec store bypass: Vulnerable Spectre v1: Mitigation; __user pointer sanitization Spectre v2: Vulnerable Srbds: Not affected Tsx async abort: Not affected Allerdings habe ich schon reichlich Firmware versionen getestet.
Last updated: 2024-06-21

Post by joachimk on Profinet Controller IP-Adresse Àndern CODESYS Forge talk (Post)
Die IP-Adresse des Profinet-Controllers soll zur Laufzeit geĂ€ndert werden. Dabei handelt es sich um eine Anwendung auf einem PC mit einer Standard-Ethernetschittstelle (ControlWinV3+WinPcap). Die Datei "CODESYSControl.cfg" wurde dazu angepasst: .... Adapter.0.Name="Ethernet 4" Adapter.0.EnableSetIpAndMask=1 Die konfigurierte IP-Adresse wird zur Laufzeit an die tatsĂ€chliche IP-Adresse der Netzwerkschnittstelle mit dem folgenden Befehl angepasst (die Änderung von 192.168.2.33 auf 192.168.2.34 funktioniert auch): Ethernet.UpdateConfiguredIPSettings(IpAddress:=Ethernet.IPAddress, subnetmask:=Ethernet.Subnetmask, gateway:=Ethernet.GatewayAddress); Der Profinet-Controller geht danach auf Störung und gibt die folgende Fehlermeldung aus: "Controller-Status: currently active IP does not match the controller's configuration" Unter "Ethernet diagnostic information" kann man die geĂ€nderte IP-Adresse von 192.168.2.34. Ethernet lĂ€uft auch ohne Fehler. Unter "PROFINET IO Driver diagnostic information" -> "IPParameter" sieht man noch die alte (konfigurierte) IP-Adresse 192.168.2.33. Wie kann man die Störung beseitigen? Leider habe ich keine Methode zum Ändern der IP-Adresse auf dem Profinet-Controller gefunden? Reconfiguration des Profinet-Controllers?
Last updated: 2024-06-27