Post by calviniscoding on Publish a JSON payload via MQTT Publish (using IIot Libraries)
CODESYS Forge
talk
(Post)
Are you able to dynamically change the JSON message? As in, if wsValue or iValue is linked to some real telemetry that varies over time, will the JSON message reflect these changes? I am only able to send the values that I initialize the JSON message to
Last updated: 2024-06-18
Post by gatto on variables between two applications
CODESYS Forge
talk
(Post)
No. As you can see in the uploaded image, in my test project, I have a variable list GVL_1 which is located in appication_1. But if I write in POU_2, which is instead found in application 2, I cannot find the variables of GVL_1. it seems that the GVLs are children of each app
Last updated: 2024-06-24
Post by koppit on SysComRead Timeout Parameter
CODESYS Forge
talk
(Post)
Im using SysCom ver. 3.5.17.0 and seem to have the same issue on a Raspberry Pi. It's not waiting for the requested number of bytes, no matter if "ulTimeout := SYS_INFINITE" or any other value. The only solution I have found is to stall the program to allow the serial port to recieve the data.
Last updated: 2024-06-26
Post by snguyen on Any ways to prevent Infinite scroll when moving an object to the left or top edge?
CODESYS Forge
talk
(Post)
I've been making few HMIs and I'm starting to get annoyed that whenever I try to align an object to the left or top side of the frame, it quickly scrolls into that direction infinitely. Is there a way to prevent that?
Last updated: 2025-10-24
Post by denizerm on Deploy Control SL cant find Podman
CODESYS Forge
talk
(Post)
I found something that might be the main cause for this: /etc/os-release features the ID=debian entry on my reference system; When i temporarily override my DUTs os-release to feature ID=debian or similar its able to detect Podman. Is there a way to fix this behaviour?
Last updated: 2025-10-24
Post by salmawis on Advice on OOP hardware I/O code structure
CODESYS Forge
talk
(Post)
Call 10 FB instances. Connect Motor_1_Fault to the i_xHW_FaultDetected pin of FB 1, Motor_2_Fault to FB 2... By doing this, your FB will be flexible. The programming will be smooth like a perfect Drift Boss, instead of "hitting the wall" because it can't be reused!
Last updated: 2 days ago
Post by damian177 on Codesys and SMS in RPi
CODESYS Forge
talk
(Post)
I tried initialize my GSM modem by write simple application in C, and GSM modem works, below used AT commands: AtChat: T : "AT" AtChat: F : "OK" AtChat: T : "AT+CMEE=1" AtChat: F : "OK" AtChat: T : "AT+CMGF=0" AtChat: F : "OK" AtChat: T : "AT+CGMI" AtChat: F : "WH_Ltd" AtChat: F : "WH_GM35" AtChat: F : "Revision: RDA BV5" AtChat: F : "OK" AtChat: T : "AT+CGMM" AtChat: F : "WH_GM35" AtChat: F : "OK" AtChat: T : "AT+CGMR" AtChat: F : "Revision: GM35-D_B5_R05_A01_D170914" AtChat: F : "OK" AtChat: T : "AT+CGSN" AtChat: F : "868221045990218" AtChat: F : "OK" AtChat: T : "AT+CNMI=2,1,0,1,0" AtChat: F : "OK" AtChat: T : "AT+CLIP=1" AtChat: F : "OK" AtChat: T : "AT+COPS?" AtChat: F : "+COPS: 0,2,\"26002\"" AtChat: F : "OK" operator name: "26002" AtChat: T : "AT+CREG?" AtChat: F : "+CREG: 1,1" AtChat: F : "OK" at+creg Modem is initialized I do not understand why Codesys SMS library send AT+CPIN? command ?
Last updated: 2023-09-29
Post by captaincookie on increase default string length in queue
CODESYS Forge
talk
(Post)
Hello, I'm using Codesys V3.5 SP18 Patch 4. In the ElementCollectionExample Project from Codesys, I test the SimpleQueueExample in a Control Win V3 x64 environment. I try to add a string of 95 characters length to a queue. The default length of strings is defined as 80 characters. In the initialization of a string variable, it is possible to increase the length by the definition of e.g. STRING(1000). But when I write the string defined like this to the queue, only 80 characters are written to it and the rest is missing. I think the default length is still set in the queue definition, so it is necessary to change this, isn't it? Is there any option to increase the default length of strings in the queue? Attached you can find the used project. Thanks in advance. If any information are missing or my description unclear please let me know.
Last updated: 2023-10-05
Post by annd on Migration von "CODESYS Control for PFC200 SL" zu WAGO FW26 "CODESYS V3.5.19.2"
CODESYS Forge
talk
(Post)
Ich hab's hinbekommen: Nach dem Controller Update hab ich ein neues Projekt gemacht und nur den PFC200(8212) eingefügt (es erscheint dann ein leerer Kbus und eine serielle Schnittstelle COM1). Dann hab ich mich am Controller eingeloggt und den Kbus (Rechtsklick: Geräte suchen) mit allen Modulen automatisch ergänzen lassen. Bei den leeren Modulen hab ich dann das E/A-Abbild in csv exportiert. Dasselbe hab ich bei meinem alten "PFC200 SL" Projekt gemacht. Und dann in Excel alle Variablennamen in die leeren csv kopiert und danach wieder im neuen Projekt importiert. Dann hab ich noch alle Programmblöcke, Tasks, Visualisierungen und auch Modbus TCP Master u. Slave und auch Modbus COM Port Master und Slave in das neue Projekt kopiert. Weiters hab ich alle notwendigen Bibliotheken im Bibliotheksverwalter eingefügt. Dann noch ein paar kleine Fehler korrigiert (ich musst einen anderen Block zum Lesen der Uhrzeit nehmen) bis ich das neue Projekt fehlerfrei übersetzen konnte. Dann konnte ich es auf den Wago Controller übertragen und direkt starten. Es sieht so aus, dass alles läuft. Gruß annD
Last updated: 2023-11-18
Post by climblinne on Calling OPC UA Methods from UaExpert
CODESYS Forge
talk
(Post)
Hello, I hope someone could help me. I installed the newest Codesys 3.5 SP 20 Patch 1. When loading the demo files from @i-campbell I can upgrade them to the latest version and everthing works on the OPC-UA client side as expected (object "a" is visible, I can use the "ExampleMethod"). Now I * remove the "Information Model", * delete the "OPC_UA_Symbols Objects", * Add "Information Model" again * add "TestRootObjectType" again and "Generate IEC declarations" * and search for mapped instances (to get instance "a" again) Very good still working as expected. Now I delete the OPC_UA_Symbols and add it again referring to the "objecttest" from 16.9.2020. Also I redo the steps from above. The result is now, that I can't see the "a" object in the "Root/Objects" folder. Why ist this and how can I make it running? I think, it could may be a different version of the UA configuration file. I tried to build my own model definition files and got the same problem (but I am really not an expert). When someone has a actual model, which is also running in the actual Codesys I would be very grateful. Or even better, how to make the correct model in e.g. UA Modeler SW (I followed the description https://documentation.unified-automation.com/uamodeler/1.6.0/html/howprojnet_sec.html).
Last updated: 2024-07-01
Post by psychoengineer on Cannot Save CSV File on Windows Computer Using CODESYS and Control Win
CODESYS Forge
talk
(Post)
I am currently working on a project using CODESYS and Control Win on a Windows computer. I've encountered an issue where I am unable to save a CSV file. I have followed the standard procedures and used the appropriate file handling functions, but the file is not being created or saved as expected. IF xStartTest THEN sFileName := '\logs.txt'; sFileName := CONCAT(gvl.g_sMainDirectory, sFileName); sFileNameCopy := '\CAAFileCopy.txt'; sFileNameCopy := CONCAT(gvl.g_sMainDirectory, sFileNameCopy); //eWriteState := FILE_OPEN_TRIGGER; xTestDone := FALSE; xError := FALSE; xStartTest := FALSE; END_IF VAR_GLOBAL g_sMainDirectory : STRING := 'C:\LogFiles'; // file path for CSV file END_VAR Despite this, the file does not appear in the specified directory, and no error messages are being generated. I've checked the directory permissions and ensured that the path is correct. Has anyone else experienced a similar issue or have any suggestions on how to resolve this? Any help would be greatly appreciated. Thank you!
Last updated: 2024-07-04
Post by tyronnosaurus on ReceiveWatchdog FB not working on J1939 P2P PGNs
CODESYS Forge
talk
(Post)
Hi guys. I've got a device that sends a status message over J1939 and a PLC running Codesys to receive it. This message uses a P2P PGN (as opposed to a broadcast PGN). Codesys can only read it if I mark the J1939_ECU as "Local" (see screenshot 1). The message is received correctly, that is not the problem. The problem is detecting if the message stops being received. Local ECUs have no Watchdog checkbox to detect if the message has been received in the last X seconds. In order to implement a watchdog, I've used a ReceiveWatchdog FB. The same code works well for any non-P2P message, but doesn't work for this particular P2P message I'm trying to monitor. Even if I physically disconnect the device, ReceiveWatchdog.xBusy stays True, and ReceiveWatchdog.xError never triggers due to a timeout error. Is there any caveat in the ReceiveWatchdog FB that makes it unable to monitor P2P PGNs in Local J1939_ECUs?
Last updated: 2024-07-11
Post by biiebs on Aufbau von Ablaufsteuerungen ermitteln
CODESYS Forge
talk
(Post)
Hallo Zusammen, gibt es in CODESYS bei Ablaufsteuerungen weitere Möglichkeiten außer den AS-Einstellungen z.B. die Aufbaustruktur der Ablaufsteuerung herauszufinden? Gesamtanzahl der verwendeten Aktionen / Schritte - Im besten Fall auch die einzelnen Verzweigungen? Ich würde den gesamten Aufbau der Schrittkette gerne als "View" in einer übergeordneten Software abbilden lassen, da sich die Ablaufsteuerungen, je nach Projekt im Aufbau unterscheiden bräuchte ich die Kenntniss über den Aufbau dieser Schrittketten. Oder müsste ich mir hier einen "Workaround" programmieren, der z.B. bei Init erstmal den Aufbau der Ablaufsteuerung durchläuft und mir die nötigen Informationen liefert? Natürlich wäre auch ein Weg den Aufbau des AS-Bausteins über die PLCopen XML zu exportieren, jedoch müsste dies bei Änderungen jeweils nachgezogen werden - was etwas unschön wäre, falls dies vergessen würde. Mittlerweile habe ich auch das Tool "SFC Visu Generator" gefunden, dessen Funktion im Prinzip genau das darstellt, was ich benötige - jedoch leider nur als CODESYS interne Visualisierung. Ich würde den Export des Bausteins gerne in meine übergeordnete Software implementieren. Gibt es hier die Möglichkeit das Vorgehen zu Erfahren oder den vom Baustein generierten Export bei mir zu implementieren? Hat hier jemand sowas ähnliches schonmal gelöst? Vielen Dank im Voraus Mit freundlichen Grüßen Biiebs
Last updated: 2024-07-25
Post by paulorb on STRUCT AT %MW1000
CODESYS Forge
talk
(Post)
Hi I am trying to use STRUCT to parse commands from Modbus/TCP, Modbus client will fill the bytes related to a specific command (type, parameters), then PLC (Codesys) will access the command parameters. A STRUCT will simplify a lot the process of parsing the data, so I don't need to parse byte per byte, address will be mapped to a struct and I can use it for parsing the data. From what I understood, the compiler does not allow me to specify the location of the struct for a %MW register. VAR_COMMAND AT %MW1002: structGenericModbusCommand; This will throw: Bad declaration, use '%ML' for 'structGenericModbusCommand' variable But If I change it to %ML, when you go online you see that it is actually allocating the struct in another memory address. When we go online, on GVL we can see: VAR_COMMAND. structGenericModbusCommand %ML1002 commandType COMMANDTYPE %MB8016 ... %MB8020 I am not specifying a pointer or a reference it is a struct type, why is it mapping to a %MW location (random one). How can I control where it is mapping to? I need a consistent way to map STRUCT to specific modbus address. Is it possible? Thanks, Paulo Note I am using a Codesys OEM: Schneider Machine Expert Logic Builder (M241)
Last updated: 2024-08-13
Post by s1ack on Request a dark mode for CODESYS
CODESYS Forge
talk
(Post)
and other colors have to be licensed? Introducing Code-Based Licensing Code Basic S: White text w/ grey background (ST only) Code Basic M: White text w/ dark gray background (ST Only) Code Basic L: White test w/ black background (ST Only) Code Standard S: 2 Colors of light syntax highlight colors w/ black background. (ST Only) Code Standard M: 4 Colors of light syntax highlight colors w/ black background. (ST only) Code Standard L: 6 Colors of light syntax highlight colors w/ black background. (ST only) Code Performance S: 2 Colors of light syntax highlight colors w/ user definable background. (Entire IDE) Code Performance M: 4 Colors of light syntax highlight colors w/ user definable background. (Entire IDE) Code Performance L: 6 Colors of light syntax highlight colors w/ user definable background. (Entire IDE) You get the gist... I used to be a big fan of CoDeSys. Recent re-entry after 5 years away, not so much.
Last updated: 2024-11-15
Post by andrax on Bosch BME 280 bzw 688 Sensor per I2C Bus steuern und Daten in Codesys verarbeiten
CODESYS Forge
talk
(Post)
Die Geräte Bibliothek von Stefan Dreyer ist dafür gedacht, um Treiber für deine Sensoren zu erstellen, damit sie an einem MUX-Board betrieben werden können. Auch ist ein Betrieb ohne MUX-Board möglich. Der Aufbau ist relativ einfach und besteht aus folgenden Komponenten: -Initialize (hier wird die .devdesc.xml eingelesen) -BeforeWriteOutputs (ruft initDevice auf und ist für ausgehende Signale gedacht) -initDevice (initialisiert den Sensor) -AfterReadInputs (Selbsterklärend, Werte einlesen und Signalkonversation) Bei meinen Sensoren habe ich es immer so gemacht. Zuerst habe ich mit die .devdesc.xml gebaut bzw. eine Vorlage umgeschrieben, wobei Parameter 1-10 für ein Mux-Board reserviert sind. In der .devdesc.xml definierst du alle wichtigen Parameter für den Sensor. Danach schreibst du die Initialize und liest die Werte ein. InitDevice ist Fleißarbeit. Für die meisten Sensoren liegt immer ein Pythonscript oder was in C bei. Du gehst die Scripte durch und baust es in Codesys nach. Im letzten Schritt baust du die AfterReadInputs. Signale einlesen und Conversation. Du solltest dir auch ein I2C-Logic Analyzer zulegen. Da Teil ist sehr hilfreich um die I2C Kommunikation mitzulesen. Wenn es irgendwo klemmt, siehst du sofort an welcher Stelle du suchen musst. Ich hab hier den AZ-Delivery Logic Analyzer! Grüße Andre
Last updated: 2025-01-11
Post by mattplc on OPC UA Codesys 3.5 Symbolkonfiguration VS Kommunikationsverwalter und Python/UA-Expert
CODESYS Forge
talk
(Post)
Hallo, bisher war die Benutzung der Symbolkonfiguration für die OPC-UA Variablen recht easy einsetzbar. Im UAExpert Tool konnte man im Klarnamen den String sehen. var1 = client.get_node("ns=4;s=|var|WAGO 750-8212 PFC200 G2 2ETH RS.Application.PLC_PRG.fbTest.StateActual") Die Anbindung an die Python opcua Library hat so eigentlich gut funktioniert. Auch zum debuggen im UAExptert, konnte man den Value so sehen wie die Varibale heißt. In meinem Fall ein Enum. Was seit längerer Zeit nicht mehr funktionier ist das eingeben von Enums. Im UAExpert kommt die Fehlermeldung "BadTypeMismatch" früher war das nicht der Fall. Da die Symbolkonfiguration demnächst bei Codesys 3.5 rausfällt, wollte ich den Kommunikationsverwalter nutzen. Jetzt schaut der String mit der Node ID komplett anders aus. Bsp.: NS5|Opaque|0x01000000A6E12A718AF7333ABAFA2D7686EF27669CF33071C7D034759DE601779DF62178E9 Hier sieht man den Value gar nicht mehr im UA Expert. In Python finde ich auch keine Möglichkeit die OPC UA Variable einzulesen. Python: var1 = client.get_node("ns=5;s=|var|0x01000000A6E12A718AF7333ABAFA2D7686EF27669CF33071C7F016759BDC7114.PLC_PRG.fbTest.sVar_1") Weiß jemand wir das in Zukunft läuft? ich hab etwas das Gefühl, das die Übergeordneten Systeme die OPC UA Variablen nicht mehr so einfach einlesen können oder mache ich etwas falsch? Danke
Last updated: 2025-01-14
Post by shubadubalu on OP UA Client - Variablen zeigen alle 0
CODESYS Forge
talk
(Post)
Hallo liebe Codesys Community :) Momentan versuche ich eine OPC-UA Verbindung aufzubauen, dabei habe ich ein komisches Verhalten festgestellt. Man sucht sich ja die Variablen indem man auf "Variablen aktualisieren" in Datasource klickt. Diese werden dann auch in der enstprechenden Variablenliste automatisch deklariert. Wird das Programm übertragen und die CPU (PFC200) gestartet, aktualisieren sich die Werte entsprechend. Mittels UA Expert passen die Werte aller Variablen. Starte ich jetzt die CPU neu (OPCUA Client), werden alle Variablen mit dem Wert 0 angezeigt. Unter "Allgemein und Diagnose" wird verbunden angezeigt. Auch UA Expert zeigt weiterhin die aktuellen Server Werte. Klicke ich erneut auf "Variablen aktualisieren" und übertrage das Programm funktioniert wieder alles. Ein Kalt / Warmstart hat leider keine Auswirkung. Auch den Server Neustarten bringt kein Erfolg. Wie schaffe ich es, dass die Variablen nach CPU Neustart auch die Werte des Servers annehmen? Ich freue mich über Tipps und Ideen. :) Weitere Informationen: CODESYS 64 3.5.20.50 CPU: WAGO PFC 200 750-8216 OPC UA Kommunikation Anonym und ohne Security-Strategie
Last updated: 2025-02-18
Post by amani on PN Controller auf Raspberry Pi 4
CODESYS Forge
talk
(Post)
Hallo zusammen, Ich mache +/- erste Schritte mit RaspberryPi und Codesys: tolle Sache! Ich habe Codesys V3.5 auf einem Raspberry Pi 4 am laufen. Ich würde damit gerne einen Profinet-Slave bedienen. Die Kommunikation läuft, nun habe ich das Problem dass ich nicht verstehe wie ich den PN-Task mit dem PLC task synchron halte: Ich muss dem Slave eine Parameter-ID übergeben und beim nächsten Zyklus die Antwort auslesen. Da es dann mehrere Parameter gibt die ich nur sequentiell auslesen kann benutze ich also einen Zähler der mir die ID's durchstept. Aktuell sieht es aus als ob dieser Zähler schneller inkrementiert als der Slave antwortet (ich habe z.Bsp. 5 Parameter, diese zeigen dann alle das gleiche oder springen zwischen den Parametern). Also kurz gesagt ich muss sicherstellen dass die Datenbytes vom Slave zur gesetzten Parameter-ID passen... Ich wäre froh um ein paar Tipps! Herzlichen Dank! Grüsse, Stephan A. Wicki
Last updated: 2025-02-26
Post by iliyatsukerman on SoftMotion auf PFC200
CODESYS Forge
talk
(Post)
Hallo, Wir würden Ihre Unterstützung bei der Überprüfung der Kompatibilität der folgenden Konfiguration sehr schätzen: • PSTR-LO-16/400FEV ELMO • SCALANCE XC208 • WAGO PFC200 750-8213/40-010 • Die SPS (WAGO) wird gleichzeitig eingesetzt als: o EtherCAT-Master zur Kommunikation mit einem Elmo-Servoantrieb (EtherCAT-Slave, 4 Achsen – generisches CiA 402-Profil), und o Modbus-TCP-Server zur Kommunikation mit einem Siemens Modbus-TCP-Client, welcher zur Fernsteuerung des Elmo-Servoantriebs über die SPS dient. Bitte bestätigen Sie, ob die SPS in der Lage ist, diese Dualfunktion — als EtherCAT-Master und gleichzeitig als Modbus-TCP-Server — ohne Konflikte oder Performanceprobleme zu unterstützen. Insbesondere interessiert uns, ob die CODESYS SoftMotion SL Basislizenz (2305000000-F) notwendig ist, um 4 Servoachsen zu steuern, und ob diese Lizenz auf einer WAGO PFC200 SPS mit CODESYS Version 3.5 Service Pack 19 Patch 40 oder höher unterstützt wird. Alle Achsen im Servoantrieb werden unabhängig voneinander gesteuert. Mit freundlichen Grüßen. ILIYA
Last updated: 2025-07-13
Post by marsmaennchen on MQTT,mehrere Topics publish/subscribe
CODESYS Forge
talk
(Post)
Hallo zusammen, ich habe im Grunde dieselbe Frage wie in diesem Thread: https://forge.codesys.com/forge/talk/Deutsch/thread/85372a6daf/ Leider hat der Threadersteller das Problem selbst gelöst, ohne seine Lösung zu teilen. Mein Setup: Ich möchte von einer WAGO PFC200 Daten per MQTT an HomeAssistant übertragen. Die Grundkommunikation steht bereits. Angenommen, man hat 50 Lichtschalter und 50 Lampen. Wie ist das übliche Vorgehen, um 50 einzelne Bool-Werte (Lichtschalter ein/aus) effizient zu übertragen? Ich finde einfach kein Beispiel, das ich als Vorlage nutzen könnte. Muss wirklich für jeden Lichtschalter ein eigenes MQTT-Topic und somit ein eigener Baustein in CODESYS angelegt werden? Also z. B. Topic/LS1/state, Topic/LS2/state usw.? Oder gibt es eine gängige, professionellere Methode, mehrere Schalter effizient zu übertragen? Zur Eingrenzung: Ich nutze die CODESYS IIoT Libraries, da die Janz Tec MQTT Library für mich bisher zu komplex ist. Kann mir jemand bitte erklären, wie Profis so etwas lösen? Vielen Dank schon mal für eure Tipps! Gruß Patrick
Last updated: 2025-10-10
Post by chalk on No source code available
CODESYS Forge
talk
(Post)
Hello, This is my first time using Codesys, I am trying to add EtherNetIP communication to a Raspberry PI. I’ve added the EtherNetIP Adapter configured the network setting and added some modules to the pi but when I download the project it generates the following error: “There is no source code available for the object because it is in the compiled library ‘cip object, 4.5.1.0 (3s – smart software solution gmbh)’. Do you want to browse for the original library in order to display the source code? There are 2 errors in the log which are: SOURCEPOSITION App=[Application] area=3, offset=332760 EXCEPTION [Application] occurred: App=[Application], Task=[ENIPAdapterServiceTask] I can’t for the life of me work out how to get around this. I can’t find the source code anywhere or any information regarding this error. I’m using Codesys V3.5 SP19 Patch 3, the version of the Ethernet adapter is 4.5.1.0 and the version of the modules is 4.1.0.0. Any help on this will be greatly appreciated. Thanks
Last updated: 2024-02-02
Post by yannickasselin on Connect to remote PLC via local pc and teamviewer
CODESYS Forge
talk
(Post)
Yes it is possible. I did it a lot of times using TeamViewer VPN. Unfortunately, TeamViewer VPN only works on Windows. If the remote PLC is a Codesys runtime running on Windows, you should be able to login directly using TeamViewer VPN if it is installed on the PC/PLC. If it is not Windows based, you can still do it but you need to have a Windows based PC acting as a gateway in the middle. In this case you need to enable IP Forwarding on the Windows remote PC (the gateway) and you need to setup the gateway IP address on the PLC to be the address of the Windows PC. Then you need to add a route on your local PC to point to the gateway PC for Codesys communication. I know it may not be detailed enough but I did not want to make a whole tutorial on how to do it. Bottom line, it is possible. I do it all the time.
Last updated: 2024-02-02
Post by fredsta on Unable to load dynamic modules (Download failed: Application=Application)
CODESYS Forge
talk
(Post)
Hey there, I am currently trying to find a good solution for the communication between CODESYS Control on Raspberry Pi and "the rest of the world", i. e. the things apart from CODESYS on my linux. My first approach was to use the c-integration. So I created a lib, defined extern fbs, compiled the code on my Pi using the SDK and put the .so into my lib project. When I try to log into the Pi and load the program, I get the error message which you can see in the attached picture. "Die dynamischen Module der C-Integration konnten nicht auf das Laufzeitsystem geladen werden" is german and means roughly "the modules from the c-integration could not be loaded onto the runtime system." Is this normal? Am I doing something wrong? I will have a look at the unix domain socket thing next, as I am still in the process of finding the best solution for the communication.
Last updated: 2024-02-15
Post by tim-roelant on Problem mit control runtime V3 und profinet
CODESYS Forge
talk
(Post)
Ich habe einen brandneuen Beckhoff-Panel-PC mit einer Codesys Control Runtime V3 eingerichtet. Ich habe es zusammen mit 2 Profinet-Feldgeräten konfiguriert: einem 16in/16out IO-Modul von Turck und einem MTS-Linearencoder. Die Maschine funktioniert einwandfrei, bis plötzlich die Kommunikation abbricht und die Profinet-Teilnehmer nicht mehr erreichbar sind. Zu diesem Zeitpunkt kann ich das Gerät noch anpingen, aber der Profinet-Master findet sie nicht mehr: Wenn ich einen Scan durchführe, werden sie nicht gefunden. Wenn ich einen Kaltstart durchführe, wird der Profinet-Master wieder aktiv und die Geräte werden wieder gefunden. Im Protokoll erhalte ich den Ethercat-Paketempfangsfehler: sysethernet. Ich bin etwas verwirrt, es gibt kein Ethercat-Gerät im Gerätebaum. Ich habe den Sendetakt und das Untersetzungsverhältnis bereits auf höhere Werte eingestellt, jedoch ohne Ergebnis. Kann Codesys so konfiguriert werden, dass die Kommunikation ohne Kalt-Reset wiederhergestellt wird? Das ist sehr ärgerlich und verursacht viele Produktionsausfälle. Grüße Tim
Last updated: 2024-02-27