  • eschwellinger eschwellinger posted a comment on discussion Engineering

    Are you using profinet controller or profinet device?

  • eschwellinger eschwellinger modified a comment on discussion Automation Server

    if you write a request to 'my question' CODESYS store - maybe would help...to push it

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    Hi, which version is it, Check by plcshell command If it is available... BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Motion

    Hi, I would update the Softmotion via Package Manager in CODESYS. Set all to newest - and seems that the Ethercat Master need an update too. (rightlick in the device tree -> update device) Best Regards Edwin

  • eschwellinger eschwellinger posted a comment on discussion Motion

    Hi, you need to install the device descriptions into the device repository: https://forge.codesys.com/drv/sm3raspistepper/code/HEAD/tree/tags/Release_1.0/devdesc/ BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Automation Server

    if you write a request to 'my question' CODESYS store - maybe would help...

  • eschwellinger eschwellinger posted a comment on discussion Automation Server

    Hi, the missing part is the activated UserManament in the eCockpit plc's. So I guess it will still not work. Edwin

  • eschwellinger eschwellinger modified a comment on discussion Motion

    Hi, Usually this is mit a problem, USB or internal Ethernet Interface. Both work like charm as long you do not mix up ethercat and other TCP/ip ethernet devices. For Softmotion the important thing is to have a realtime Patch rt_prempt Patch applied to your Linux kernel. ( Sure this is not needed for Softmotion light) This etherberry is as far as i know only for making a ethercat Slave on your Raspberry Pi BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Motion

    Hi, Usually this is mit a problem, USB or internal Ethernet Interface. Both work like charm as long you do mit mix up ethercat and other TCP/ip ethernet devices. Die Softmotion the important thing is to have a realtime Patch rt_prempt Patch applied to your Linux kernel. This etherberry is as far as i know only for making a ethercat Slave of your Raspberry Pi

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    Sure just use the workaroud..

  • eschwellinger eschwellinger posted a comment on discussion Deutsch

    du musst Content-Length im Header setzen: also Content-Length: 0

  • eschwellinger eschwellinger posted a comment on discussion Engineering

    Hi, start here: https://help.codesys.com/webapp/oxvisIujE0YbnEvay2vz2A6FFPI%2FRDREC;product=CommFB;version=3.5.15.0 or here aproject example: https://forge.codesys.com/forge/talk/Runtime/thread/04361f89ec/?limit=25#b3dc BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Engineering

    Hi, I think the only way this might work, if you do not really need SoftMotion, you might could give 'SoftMotion light' a try. If you have only point to point movement with the CANopen drives, this should work with Control Win. BR Edwin

  • eschwellinger eschwellinger modified a comment on discussion Engineering

    Hi, if you use 3.5SP16 (or 3.5SP16Patch1) so current version, you need to install the EdgeGateway Package via Shopping cart on your CODESYS. Then deploy the Edge Gateway to your PI. ( you need to deploy armhf) -Order CODESYS Automation Server in the Store ( free of charge). -Then add the Edge Gateway to your Server. Then you could connect from outside to your PI. (CODESYS Developmentsystem Login and webvisu access) Thats the whole story. Best Regards Edwin

  • eschwellinger eschwellinger modified a comment on discussion Engineering

    Hi, if you use 3.5SP16 (or 3.5SP16Patch1) so current version, you need to install the EdgeGateway Package via Shopping cart on your CODESYS. Then deploy the Edge Gateway to your PI. ( you need to deploy armhf) -Order CODESYS Automation Server in the Store ( free of charge). -Then add the Edge Gateway to your Server. Then you could connect from outside to your PI. (CODESYS Login and Webvisu Acess) Thats the whole story. Best Regards Edwin

  • eschwellinger eschwellinger modified a comment on discussion Engineering

    Hi, if you use 3.5SP16 (or Patch1) so current version, you need to install the EdgeGateway Package via Shopping cart on your CODESYS. Then deploy the Edge Gateway to your PI. ( you need to deploy armhf) -Order CODESYS Automation Server in the Store ( free of charge). -Then add the Edge Gateway to your Server. Then you could connect from outside to your PI. (CODESYS Login and Webvisu Acess) Thats the whole story. Best Regards Edwin

  • eschwellinger eschwellinger modified a comment on discussion Engineering

    Hi, if you use 3.5SP16 (or Patch1) so current version, you need to install the EdgeGateway Package via Shopping cart on your CODESYS. Then deploy the Edge Gateway to your PI. Order CODESYS Automation Server in the Store ( free of charge). Then add the Edge Gateway to your Server. Then you could connect from outside to your PI. (CODESYS Login and Webvisu Acess) Thats the whole story. Best Regards Edwin

  • eschwellinger eschwellinger posted a comment on discussion Engineering

    Hi, if you use 3.5SP16 (or Patch1) so current version, you need to install the EdgeGateway Package via Shopping cart on your CODESYS. Then deploy the Edge Gateway to your PI. Order CODESYS Automation Server in the Store ( free of charge). Then add the Edge Gateway to your Server. Then you could connect from outside to your PI. (CODESYS Login and Webvisu Acess) Thats the whole story. Best Regards Edwin

  • eschwellinger eschwellinger modified a comment on discussion Engineering

    for login to a remote plc: https://www.youtube.com/watch?v=8KLywg51Xyk to see webvisu from the remote plc: https://www.youtube.com/watch?v=Kyf9bCpPa6s and by the way sure the first steps: https://www.youtube.com/watch?v=iiPKyyO4M00

  • eschwellinger eschwellinger posted a comment on discussion Engineering

    for login to an remote plc: https://www.youtube.com/watch?v=8KLywg51Xyk to see webvisu from the remote plc: https://www.youtube.com/watch?v=Kyf9bCpPa6s and by the way sure the first steps: https://www.youtube.com/watch?v=iiPKyyO4M00

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    yes agree, but only PI4 seems to have this issue, the workaround is: just use 2020-05-27-raspios-buster-armhf.img without apply these updates. Till this will be fixed ( hopefully in Patch2) BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Visualization

    ahh.. which plc do you want to connect with that?

  • eschwellinger eschwellinger posted a comment on discussion Engineering

    Hi, which plc in which version are you using? Could you enable CANOPEN_DEBUG as compiler define ( not needed =>3.5SP16 Then attach the plclogger - maybe the can trace too. "Unfortunately the Manager sends a ResetNode to all of my devices without any reason" without a reason, the manager certainly doesn't There will be a heartbeat error probably?! BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    what does: cat /proc/cpuinfo report?

  • eschwellinger eschwellinger posted a comment on discussion Codesys V2.3

    In rare case at least parts of the project could be recovered...send a bug report to the CODESYS Store - my question including the project BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    OK we will check...

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    Hi, which version was installed before you apply these update command? Could just install current version: https://www.raspberrypi.org/downloads/raspberry-pi-os/ I'm pretty sure this will work then. Best Regards Edwin

  • eschwellinger eschwellinger posted a comment on discussion Deutsch

    Hallo, ich denke funktionieren tut erst mal nur die Visu in CODESYS - nicht mit dem externen Dali Konfigurator...! Könnte sein das du mit der Standard Firmware booten auf SD Karte booten musst und dann sollte der Konifgurator dann auch gehen. ( ich denke das ist das selbe Problem mit Wago Io Check wofür es einen Punkt gibt bei uns der mal behoben werden wird) Wie gesagt der Workaround ist mit Wago FW SD Karte zu booten und dann sollte IOCheck und auch der Dali Konfigurator gehen. Hoffe das bringt...

  • eschwellinger eschwellinger modified a comment on discussion Runtime

    hi, in my case this works like charm. Could you check if predictcable network names are enabled? This should be turned of under raspi-config .. you could start the plc manually by: sudo /etc/init.d/codesyscontrol stop cd /var/opt/codesys sudo /opt/codesys/bin/codesyscontrol.bin -d /etc/CODESYSControl.cfg open second CLI tail -f /tmp/codesyscontrol.log for Multicore you need to use: cd /var/opt/codesys sudo /opt/codesys/bin/codesyscontrol_armv7l_raspberry.bin -d /etc/CODESYSControl.cfg to have detailed...

  • eschwellinger eschwellinger modified a comment on discussion Runtime

    hi, in my case this works like charm. Could you check if predictcable network names are enabled? This should be turned of under raspi-config .. you could start the plc manually by: 1. sudo /etc/init.d/codesyscontrol stop 2. cd /var/opt/codesys sudo /opt/codesys/bin/codesyscontrol.bin -d /etc/CODESYSControl.cfg second CLI tail -f /tmp/codesyscontrol.log for Multicore you need to use: cd /var/opt/codesys sudo /opt/codesys/bin/codesyscontrol_armv7l_raspberry.bin -d /etc/CODESYSControl.cfg to have detailed...

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    hi, in my case this works like charm. Could you check if predictcable network names are enabled? This should be turned of under raspi-config .. you could start the plc manually by: 1. sudo /etc/init.d/codesyscontrol stop 2. cd /var/opt/codesys sudo /opt/codesys/bin/codesyscontrol.bin -d /etc/CODESYSControl.cfg second CLI Tail -f /tmp/codesyscontrol.log for Multicore you need to use: cd /var/opt/codesys sudo /opt/codesys/bin/codesyscontrol_armv7l_raspberry.bin -d /etc/CODESYSControl.cfg to have detailed...

  • eschwellinger eschwellinger posted a comment on discussion Deutsch

    Hi, du kannst das Kommando auch manuell hinzufügen unter Tools -> Customize Grüße Edwin

  • eschwellinger eschwellinger posted a comment on discussion Engineering

    Hi, you need to copy them to : *c:\ProgramData\CODESYS\Licenses* if you activate a 'SL' license / PFC / Raspi / BBB ... CODESYS will add a dirctory with the name of the ticket and add the license backupfile into this directory seiralno.WibuCmRau Example: 000000005293658c.WibuCmRau So with this you could reactivate at any new installation of the SD card the device ( you just need to identify the correct SN) So in your case I would propose to just copy your LicenseUpdate files to this location. This...

  • eschwellinger eschwellinger posted a comment on discussion Engineering

    Hi Jefferson, no real idea at the moment I would check the plc logger. BR Edwin

  • eschwellinger eschwellinger modified a comment on discussion Engineering

    should work.. filepath: '/var/opt/codesys/PlcLogic/'

  • eschwellinger eschwellinger posted a comment on discussion Engineering

    should work..

  • eschwellinger eschwellinger posted a comment on discussion Motion

    check the prios of the tasks ( see more than one prio 1??) and I would recommend to call all motion fb in the Ethercat Task kontext ( In our case the Main task with 4ms? BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Motion

    Hi, all motion fb's should be exectuted in the Motion task, which is equal Ethercat task. Which plc is this? Is there a realtime patch applied in case it is a Linux based system? Check the jitter times in the taskmonitor when you are online. BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Deutsch

    ich denke, du musst du dein CODESYS Projektarchiv an den CODESYS Store Helpdesk -> meine Frage schicken.

  • eschwellinger eschwellinger modified a comment on discussion Engineering

    .. not tired of preaching that exactly this is a typical task for using CODESYS Automation server. There is one important restriction - at the moment this does not work with e!Cockpit. Till then, you might use CODESYS V3 on PFC side and CODESYS V3 as development system. Later if implemented you could switch back to e!COCKPIT - ( missing UserManagement - on Automation server side). You could reach the webvisu via Automation server and you could login via the Automation Server to the PFC's. ( no Teamviewer...

  • eschwellinger eschwellinger modified a comment on discussion Engineering

    .. not tired of preaching that exactly this is a typical task for using CODESYS Automation server. There is one important restriction - at the moment this does not work with e!Cockpit. Till then, you might use CODESYS V3 on PFC side and CODESYS V3 as development system. Later if implemented you could switch back to e!COCKPIT - ( missing UserManagement - on Automation server side). You could reach the webvisu via Automation server and you could login via the Automation Server to the PFC's. ( no Teamviewer...

  • eschwellinger eschwellinger modified a comment on discussion Engineering

    .. not tired of preaching that exactly this is a typical task for using CODESYS Automation server. There is one important restriction - at the moment this does not work with e!Cockpit. Till then, you might use CODESYS V3 on PFC side and CODESYS V3 as development system. Later if implemented you could switch back to e!COCKPIT - ( missing UserManagement - on Automation server side). You could reach the webvisu via Automation server and you could login via the Automation Server to the PFC's. ( no Teamviewer...

  • eschwellinger eschwellinger posted a comment on discussion Engineering

    .. not tired of preaching that exactly this is a typical task for using CODESYS Automation server. There is one important restriction - at the moment this does not work with e!Cockpit. Till then, you might use CODESYS V3 on PFC side and CODESYS V3 as development system. Later if implemented you could switch back to e!COCKPIT - ( missing UserManagement - on Automation server side). You could reach the webvisu via Automation server and you could login via the Automation Server to the PFC's. ( no Teamviewer...

  • eschwellinger eschwellinger modified a comment on discussion Runtime

    Let me check, seems we mis a posibility to force the lib to use either TLS 1.1 or 1.2

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    Check the modem documentaion... To Figuren Out which device on the Pi /dev/tty.... Ist used

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    Let me check, seems we muss a posibility to force the lib to use either .TLS 1.1 or 1.2

  • eschwellinger eschwellinger modified a comment on discussion Motion

    Hi, go back to the working project with G5 driver not adding DS402 below thge Omron slave. You need to call your motion fb's in the Ethercat task. (Just drag the PLC_PRG in the taskkonfig below the Ethercat task. see red arrow) BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Motion

    Hi, go back to the working project with G5 driver not adding DS402 below thge Omron slave. You need to call your motion fb's in the Ethercat task. BR Edwin

  • eschwellinger eschwellinger modified a comment on discussion Runtime

    Hi, sure should work, we need more details, scereenshot error numbers... and this should work even in the 2h unlicensed mode. Which Runtime/CODESYS Version and which Wago Firmware is on the PFC100? Regards Edwin

  • eschwellinger eschwellinger modified a comment on discussion Runtime

    Hi, sure should work, we need more details, scereenshot error numbers... and this works even in the 2h unlicensed mode. Which Runtime/CODESYS Version and which Wago Firmware is on the PFC100? Regards Edwin

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    Hi, sure should work, we need more details, scereenshot error numbers... and this works even in the 2h unlicesned mode. Regards Edwin

  • eschwellinger eschwellinger posted a comment on discussion Motion

    Hi, just download an project which has only the ethercat master in the device tree, then rightclick on the master and scan the slave and add it that way to the project. Don't care on addresses on ethercat. You need to call the PLC_PRG ( Motion fb's) in the Ethercat Master context... Then check the logger- for more details if the drive does not go up operational. BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    Hi, if your modem support the follwoing at commands: Used AT-Commands AT+CMGS: Send Message AT+CMGR: Read Message AT+CMGL: List Messages AT+CMGD: Delete Message AT+CMGF: Message Format AT+CPMS: Preferred Message Storage AT+CSCA: Service Center Address AT+CMEE: Error Message Format AT+CREG: Network registration it might work. You need to add the comport here: /etc/CODESYSControl_Users.cfg [SysCom] Linux.Devicefile.1=/dev/ttyS0 That's it... example project comes with the SMS package. Regards Edwin

  • eschwellinger eschwellinger posted a comment on discussion Codesys V2.3

    Hi, For some reason the installation information in C:\Program Files (x86)\InstallShield Installation Information{07976ABB-1EBD-4A65-A7C7-155A0DC17173} was broken. Please delete this key (or renamed it). This means that CODESYS can no longer be uninstalled, but a new setup will be successful. The installation directory of the old version must then either be deleted or renamed or a different directory must be selected for the new installation. Best Regards Edwin

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    check: 1. Core assignment is ok? (-> becdedit on CLI) for your system 2. Hyper V disabled ( bcdedit - > bcdedit /set hypervisorlaunchtype off 3. secure boot on Windows disabled Best Regards Edwin

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    login by ssh client (putty or any other) to the pi and check by using 'top' is the gateway is up and running BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Visualization

    Hi, in CODESYS... which plc and which version is this?

  • eschwellinger eschwellinger posted a comment on discussion Visualization

    Hi, could you attach the plc log file for this situation? Regards Edwin

  • eschwellinger eschwellinger posted a comment on discussion Visualization

    Hi, could you attach the plc log file for this situation? Regards Edwin

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    did you install the Linux Edge using the shoping card in CODESYS? Do not forget to restart CODESYS after the installation process. BR Edwin

  • eschwellinger eschwellinger modified a comment on discussion Runtime

    Hi, after installing the package there is an own update command for the Edge Gateway. Automation Server is an own separate product - which uses the Edge Gateway to login to the plc's. It is worth to try - you could see the Webvisu https://www.youtube.com/watch?v=Kyf9bCpPa6s additional beside login to remote plc's with CODESYS. Regards Edwin

  • eschwellinger eschwellinger modified a comment on discussion Runtime

    Hi,

  • eschwellinger eschwellinger modified a comment on discussion Runtime

    Hi,

  • eschwellinger eschwellinger modified a comment on discussion Runtime

    Hi,

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    Hi,

  • eschwellinger eschwellinger modified a comment on discussion Runtime

    Hi, you need to Install the Edge gateway Plugin (Linux)from the CODESYS Store: https://store.codesys.com/cas/codesys-edge-gateway.html#All%20versions and deploy the armhf Edge Gateway to the Pi. Do not forget to check if using the CODESYS Automation Server would be an option for that you could login via Automation Server to your plc / Rev Pi: https://www.youtube.com/watch?v=8KLywg51Xyk Best Regards Edwin

  • eschwellinger eschwellinger modified a comment on discussion Runtime

    Hi, you need to Install the Edge gateway Plugin (Linux)from the CODESYS Store: https://store.codesys.com/cas/codesys-edge-gateway.html#All%20versions and deploy the armhf Edge Gateway to the Pi. Do not forget to check if using Automation Server would be an option for that you could login via Automation Server to your plc: https://www.youtube.com/watch?v=8KLywg51Xyk Best Regards Edwin

  • eschwellinger eschwellinger modified a comment on discussion Runtime

    Hi, you need to Install the Edge gateway Plugin (Linux)from the CODESYS Store.. and deploy the armhf Edge Gateway to the Pi. Best Regards Edwin

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    Hi, you need to Install the Edge gateway Plugin (Linux)from the CODESYS Store.. and depliy the armhf Edge Gateway to the Pi. Best Regards Edwin

  • eschwellinger eschwellinger posted a comment on discussion Motion

    Hi, could you add the project to check? Guess the IPOTask should the one with the 4ms and highest prio and not the SoftMotion_PanningTask?! BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Engineering

    Hi, the easy approach is for sure this: (I know you do not want to hear it - this is my last try) ;-) https://www.youtube.com/watch?v=8KLywg51Xyk&t=6s If you do it without CODESYS Automation server you should read this: https://customers.codesys.com/fileadmin/data/customers/security/CODESYS-Security-Whitepaper.pdf Especially Chapter 7. Networks ports used by CODESYS As described, controllers are designated to be programmed. Thus, CODESYS compatible controllers need certain open network ports for...

  • eschwellinger eschwellinger posted a comment on discussion Engineering

    Hi, which version is this and is devicediag enbaled`?

  • eschwellinger eschwellinger posted a comment on discussion Deutsch

    aber die Geräte werden ja schon noch supportet vor allem wäre ja dann die IO Link Gerätebeschreibung eventuell falsch.... ETC_ADS_IoLinkRead

  • eschwellinger eschwellinger modified a comment on discussion Runtime

    For plc as Profinet device no additional hardware is needed. Control RTE and even Control Win work as profinet device without.

  • eschwellinger eschwellinger modified a comment on discussion Runtime

    Profinet device no additional hardware is needed.. Control RTE and even Control Win Work as profinet device without

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    Profinet device no extra Hardware ist needed.. mit dir Control RTE even mit dir Control Win

  • eschwellinger eschwellinger posted a comment on discussion Deutsch

    Hi, also ich würde mal den IFM Support fragen... Grüße Edwin

  • eschwellinger eschwellinger modified a comment on discussion Deutsch

    dann passt es doch:

  • eschwellinger eschwellinger posted a comment on discussion Deutsch

    dann passt es doch:

  • eschwellinger eschwellinger modified a comment on discussion Automation Server

    ... https://www.youtube.com/watch?v=8KLywg51Xyk&feature=youtu.be now possible.

  • eschwellinger eschwellinger posted a comment on discussion Automation Server

    ... https://www.youtube.com/watch?v=8KLywg51Xyk&feature=youtu.be now possible.

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    Hi, yes... but here in the config. BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    Hi, you need to export the gsdml via Tools->Device Repository Best Regards Edwin

  • eschwellinger eschwellinger modified a comment on discussion Deutsch

    Hallo, es gibt Ethercat ESI files für das Gateway also AL1030 die hast du ja installiert, aber es gibt auch IO-Link XML files die deine IO Link Geräte beschreiben, auch die musst du in CODESYS installieren. Dann macht der Ethercat IO-Link alles für dich - das mapping usw... Darum habe ich dich schon mehrmals versucht zu fragen: Welches IO-Link Gerät verwendest du? Da muss man nichts machen, mit Indes SubIndex lesen oder der gleich einfach das IO-Link XML installieren und dann eben das passende Gerät...

  • eschwellinger eschwellinger posted a comment on discussion Deutsch

    Hallo, es gibt Ethercat ESI files für das Gateway also AL1030 die hast du ja installiert, aber es gibt auch IO-Link XML files die deine IO Link Geräte beschreiben, auch die musst du in CODESYS installieren. Dann macht der Ethercat IO-Link alles für die - da mapping usw... Darum habe ich dich schon mehrmals versucht zu fragen: Welches IO-Link Gerät verwendest du. Da muss man nichts machen mit Indes SubIndex lesen oder der gleich einfach das IO-Link XML installieren und dann eben das passende Gerät...

  • eschwellinger eschwellinger posted a comment on discussion Deutsch

    Gibt es für dein IO Link Gerät nicht auch IO-Link XML files des Herstellers, was ist das genau für ein IO Link Gerät welches du verwendest? Diese IO-Link XMLs muss man auch ins Device Repositpory installieren wie du es mit den ESI files machst. Dann muss das gehen ohne Probleme. Grüße Edwin

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    hi, since 3.5SP15 you could do it that way: /etc/CODESYSControl_Users.cfg [SysCom] Linux.Devicefile.1=/dev/ttyUSB0 Linux.Devicefile.2=/dev/ttyS0 I assume that you access the GPIO by: /dev/ttyS0 In CODESYS later your USB serial is Com1 and GPIO Uart Com2 BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Deutsch

    Hi, welche CODESYS Version genau verwendest du, die IFM AL1030 kommt ja inklusive Ethercat Konfiguratior aus dem Setup von CODESYS, die sieht dann bei mir so aus: und da gibt es meiner Meinung nach das TxPDO IOLM_Status\Digital Inputs States of DI (Pin 2) Aber vielleicht musst du mal noch dein Projektarchiv einhängen damit man sieht welchen Sensor du am IOLink hast. Grüße Edwin

  • eschwellinger eschwellinger posted a comment on discussion Engineering

    Hi, no receipe manager does not need any license, you could use either the device reader application example for older CODESYS versions to get the infromation what is licensed on your plc or since 3.5 SP15 this is embedded in CODESYS see screenshot. BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Deutsch

    Hi, kannst du mal die ESI und IO Link files anhängen? Grüße Edwin

  • eschwellinger eschwellinger posted a comment on discussion Engineering

    Only possible If you write to 'my question' in the CODEDSYS Store..

  • eschwellinger eschwellinger posted a comment on discussion Engineering

    you need to remove SysEthernet this is not needed on Control RTE, only the CmpEt1000Drv ... and a reset cold of the pc is needed after changing the driver under windows ( means switch off an on again - after reboot windows) Then it will work. BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    Hi, I would give this a try: generate a script for example ssh-shutdown.sh with your command: ssh pi@raspberrypi -t sudo shutdown -h -P now and just execute then ssh-shutdown.sh by the codesys command. Best Regards Edwin

  • eschwellinger eschwellinger posted a comment on discussion Engineering

    Hi, check the examples from the old forum, there is on for Raspberry PI, should probably work with RTE, you need to enable the command you want to execute in CODESYSControl_User.cfg(if you are on version SP16 RTE) https://forge.codesys.com/forge/talk/Runtime/thread/04361f89ec/?limit=25&page=1#d08c Best Regards Edwin

  • eschwellinger eschwellinger posted a comment on discussion Engineering

    Hi, please check the plclogger for more information, guess you need to add the CODESYS network driver on Windows and add the component in the RTE configuration if you want to use Ethercat in your project. BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Engineering

    hi, the fact that the current values of the values are in light grey, mean that the variables are not used in the Pou's. So either use (prefered method) them ( only if used CODESYS does update them) or change it to enable2 see screenshot. Best Regards Edwin

  • eschwellinger eschwellinger posted a comment on discussion Visualization

    Hi, if you are using CNC - have you checked this example here? https://store.codesys.com/cnc-3d-editor.html BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Runtime

    Target Visu not possible to have with this BBB SL release from the store. So the only way to do it -> use webvisu in fullscreen kiosk mode in the browser. On Raspberry PI this look using webvisu and browser in fullscreen mode feel similar to targetvisu. On BBB you need to check if it is performant enough for your needs. BR Edwin

  • eschwellinger eschwellinger modified a comment on discussion Engineering

    Hi, is the end module connected on Kbus? To have this is mandatory on Kbus. BR Edwin

  • eschwellinger eschwellinger posted a comment on discussion Engineering

    Hi, is the end module connected on Kbus? BR Edwin